ABB TVOC-2-DP6 optical arc detector with a 6 m cable, designed for use with the TVOC-2 Arc Guard System to detect electrical arc faults in switchgear and power distribution equipment.
£268.41
The ABB TVOC-2-DP6 is an optical arc detector for the ABB Arc Guard System™ TVOC-2, designed to detect the intense light generated by an electrical arc fault inside switchgear, control panels and power distribution equipment. Supplied under ABB order code 1SFA664003R1060, this detector provides a dedicated sensing point for fast arc-flash detection within electrical installations.
As part of the ABB TVOC-2 Arc Guard system, the detector works with a compatible TVOC-2 arc monitor to provide rapid optical detection of arc faults. By positioning detectors close to areas where an arc could occur, the protection system can identify abnormal light conditions and initiate the configured protective response.
The TVOC-2-DP6 is supplied with a 6 m detector cable, providing flexibility when positioning the optical sensor within switchboards, motor control centres and other electrical assemblies. Its dedicated ABB connection makes it suitable for extending arc detection coverage across multiple compartments of a switchgear installation.
Electrical arc faults generate an extremely intense burst of light. The ABB TVOC-2 system uses optical detectors such as the TVOC-2-DP6 to recognise this characteristic light and send a detection signal to the arc monitor, enabling the protection system to react rapidly according to its configured trip arrangement.
Installing multiple detectors throughout electrical switchgear allows arc detection coverage to be distributed across separate compartments and high-risk areas. The 6 m cable on the TVOC-2-DP6 provides additional installation flexibility when routing the detector back to the compatible TVOC-2 monitoring unit.
Tick the specs you need, then view products that match.
| Monitoring Function | Arc flash | |
|---|---|---|
| Series | Arc Guard System™ TVOC-2 | |
| Order code | 1SFA664003R1060 | |
| Product type | Optical arc detector | |
| Detector cable length | 6 m | |
| Detection method | Optical arc-flash detection | |
| System compatibility | ABB TVOC-2 Arc Guard System™ | |
| ABB product group | Arc Guard Components |
The TVOC-2-DP6 is an optical detector used with the ABB TVOC-2 Arc Guard System™ to detect the intense light generated by electrical arc faults.
The detector is supplied with a 6 m cable, allowing flexible positioning within electrical switchgear and control equipment.
The ABB order code for the TVOC-2-DP6 6 m detector is 1SFA664003R1060.
The detector uses optical sensing to identify the intense light associated with an electrical arc and communicates the detection event to the compatible TVOC-2 arc monitor.
It is typically installed inside switchgear, switchboards, motor control centres and power distribution equipment close to areas where an electrical arc fault could occur.
ABB Arc Guard System™ TVOC-2 components are designed to provide rapid optical arc detection in electrical installations, helping protection systems react quickly to potentially damaging arc-flash events.