ABB TVOC-2-DP2 1SFA664003R1020 is a 2 m fibre-optic arc detector with a 180-degree detection angle for monitoring arc-flash light within ABB TVOC-2 protected switchgear.
£231.04
The ABB TVOC-2-DP2, order code 1SFA664003R1020, is an optical arc detector with a 2 m fibre-optic cable designed for use with the ABB TVOC-2 Arc Guard System. Installed within switchgear compartments, the detector monitors for the intense light produced by an arc flash and provides the optical detection input required by the TVOC-2 arc monitor.
Each detector consists of a fibre-optic cable connected to an optical lens. The lens provides a wide 180° detection angle and can detect arc-flash light at distances of up to approximately 3 m, depending on the intensity of the light. This allows strategic positioning of detectors throughout switchgear to provide effective optical coverage of areas where an arc fault could occur.
With its 2 m detector cable, the TVOC-2-DP2 is suitable for positioning within individual switchgear sections and electrical compartments while connecting back to compatible TVOC-2 equipment. ABB's Arc Guard System uses rapid optical detection to help minimise the duration and resulting energy of an arc-flash event.
An electrical arc produces an extremely intense burst of light and heat. The ABB TVOC-2 Arc Guard System uses optical detectors such as the TVOC-2-DP2 to identify this light rapidly. When an arc is detected, the TVOC-2 monitor can send a trip signal to the associated circuit breaker, helping shorten the duration of the fault and reduce the arc energy released within the switchgear.
The TVOC-2-DP2 detector's fibre-optic construction and wide viewing angle allow it to monitor critical areas without requiring complex active electronics at the sensing point. Multiple detectors can be strategically positioned within a switchboard to provide optical coverage of busbar sections, breaker compartments and other areas where an arc fault could develop.
Tick the specs you need, then view products that match.
| Monitoring Function | Arc flash | |
|---|---|---|
| Series | TVOC-2 Arc Guard System | |
| Order code | 1SFA664003R1020 | |
| Product type | Optical arc detector | |
| Detector technology | Fibre-optic light detection | |
| Detector cable length | 2 m | |
| Detection angle | 180° | |
| Detection distance | Up to approximately 3 m, dependent on light intensity | |
| Suitable for | ABB TVOC-2 Arc Guard System | |
| Net weight | 0.02 kg | |
| EAN / GTIN | 7320500382271 | |
| Product group | Arc Guard Components |
The ABB TVOC-2-DP2 is an optical detector for the TVOC-2 Arc Guard System, installed inside switchgear to detect the intense light generated by an electrical arc flash.
The TVOC-2-DP2 has a 2 m fibre-optic detector cable, allowing the optical sensor to be positioned within the required switchgear compartment.
The optical lens can detect light across a 180° angle, providing wide coverage of the monitored switchgear compartment.
The detector can sense light at distances of up to approximately 3 m, although the effective distance depends on the intensity of the light source.
ABB order code 1SFA664003R1020 is the TVOC-2-DP2 detector designed specifically for use with the ABB TVOC-2 Arc Guard System.
ABB TVOC-2 optical detectors provide rapid arc-light detection within switchgear, supporting Arc Guard installations designed to minimise arc-fault duration and reduce the potential consequences of an electrical arc-flash event.