ABB CSU-2LV 1SFA664002R5001 is a low-voltage current sensing unit for the TVOC-2 Arc Guard System, providing current-conditioned arc-flash protection with 0.25–4 kA nominal current measurement and Modbus RTU communication.
£1,164.62
The ABB CSU-2LV, order code 1SFA664002R5001, is a low-voltage current sensing unit designed as an accessory for the ABB Arc Guard System TVOC-2. It adds current measurement as a second condition alongside optical arc detection, helping prevent nuisance tripping while maintaining the rapid response required for effective arc-flash protection.
The CSU-2LV supports connection of 1–4 ABB Rogowski coil current sensors to monitor L1, L2, L3 and Neutral. It covers a wide nominal current measurement range of 0.25–4 kA and an overcurrent range of 0.25–12 kA, making it suitable for a broad range of low-voltage switchgear and electrical distribution applications.
With a rated supply of 24–240 V AC or 24–250 V DC, Modbus RTU communication and configurable overcurrent and warning thresholds, the CSU-2LV provides flexible integration into modern protection systems. When no overcurrent condition or internal error is present, the unit sends a continuous optical signal to the TVOC-2, enabling light and current to be combined as conditions for arc-fault tripping.
Optical arc detection provides extremely fast identification of an arc-flash event, but intense external light sources can potentially resemble the light produced by an electrical arc. The ABB CSU-2LV adds current as a second condition, allowing a compatible TVOC-2 installation to verify that an abnormal current increase accompanies the detected light before initiating the conditioned trip sequence.
The CSU-2LV uses compatible Rogowski coil sensors to measure current without the space requirements of conventional current transformers. Configurable warning and overcurrent levels, phase selection and Modbus RTU communication provide flexibility for commissioning and system integration, while the optical interface enables integration with the wider ABB Arc Guard architecture.
Tick the specs you need, then view products that match.
| Monitoring Function | Current | |
|---|---|---|
| Series | CSU-2 / Arc Guard System TVOC-2 | |
| ABB order code | 1SFA664002R5001 | |
| Product group | Arc Guard Components | |
| Product type | Low-voltage current sensing unit | |
| Application | Current conditioning for ABB TVOC-2 Arc Guard systems | |
| Nominal current measurement range | 0.25–4 kA | |
| Overcurrent measurement range | 0.25–12 kA | |
| Number of current sensor inputs | 1–4 | |
| Measured conductors | L1, L2, L3 and Neutral | |
| Compatible LV current sensors | ABB RC120 and RC200 Rogowski coil sensors | |
| Rated supply voltage | 24–240 V AC / 24–250 V DC | |
| Communication | Modbus RTU | |
| Signal relay | K1 changeover contact | |
| Operating temperature | -25 to +70 °C | |
| Storage temperature | -25 to +85 °C | |
| Dimensions (H × W × D) | 141.1 × 155.5 × 63.8 mm | |
| Weight | approx. 0.42 kg | |
| EAN | 7320500524923 |
The ABB CSU-2LV is a low-voltage current sensing unit for the TVOC-2 Arc Guard System, adding current measurement as a second condition alongside optical arc detection to help prevent nuisance tripping.
The CSU-2LV measures a nominal current range of 0.25–4 kA and an overcurrent range of 0.25–12 kA.
The CSU-2LV accepts 1–4 compatible current sensors, enabling measurement of L1, L2, L3 and Neutral in low-voltage installations.
The CSU-2LV has a rated supply voltage of 24–240 V AC or 24–250 V DC, providing flexibility for integration into industrial electrical systems.
Yes. The ABB CSU-2LV supports Modbus RTU, allowing settings and current-sensing information to be integrated with compatible monitoring and control systems.
ABB CSU-2 current sensing technology complements the TVOC-2 Arc Guard System by combining rapid optical arc detection with current measurement, helping deliver selective and dependable arc-flash protection for low-voltage electrical installations.