Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 6K.T1.0.000.2704 is a Class 10A thermal motor overload relay with an adjustable 2.7–4 A current setting range, one normally open and one normally closed auxiliary contact, manual or automatic reset capability and direct-mount compatibility with Finder 6K.13 and 6K.14 contactors.
£42.48
The Finder 6K.T1.0.000.2704 is an adjustable 2.7–4 A thermal overload relay designed to protect electric motors against sustained overload conditions when used with compatible Finder Series 6K.13 and 6K.14 industrial contactors. Part of the Finder Series 6K motor control range, this device provides thermal motor protection for appropriately designed industrial motor starter assemblies.
Featuring a Class 10A thermal tripping characteristic, the Finder 6K.T1.0.000.2704 allows the overload current setting to be adjusted within its specified 2.7–4 A range. This enables the protection threshold to be selected according to the connected motor's rated current, helping reduce the risk of overheating caused by prolonged overcurrent conditions.
The relay incorporates one normally open and one normally closed auxiliary contact for overload signalling and control circuit interruption. With direct mounting compatibility, manual or automatic reset functionality, an integrated stop button and IP20 protection, it is suitable for incorporation into professionally designed industrial electrical control equipment.
The Finder 6K.T1.0.000.2704 provides thermal overload protection for motors operated through compatible Finder 6K.13 and 6K.14 contactors. Its adjustable 2.7–4 A setting allows the relay to be configured according to the motor's rated current, helping protect motor windings and associated equipment against excessive heating caused by sustained overload conditions.
When the thermal overload relay trips, its auxiliary contacts change state. The normally closed auxiliary contact can be incorporated into the contactor control circuit to interrupt the coil supply, while the normally open auxiliary contact can provide an overload indication or fault signal to compatible monitoring equipment.
The relay's Class 10A tripping characteristic should be considered alongside the motor's full-load current, starting time and operating duty. Manual and automatic reset options provide flexibility when designing the control arrangement, although automatic reset must only be used where unintended restarting cannot create a hazard. The thermal overload relay does not replace short-circuit protection, so suitable upstream fuses or circuit breakers are also required.
Tick the specs you need, then view products that match.
| Device Type | Contactor | |
|---|---|---|
| Coil Type | AC, AC/DC, DC | |
| Manufacturer | Finder | |
| Series | 6K | |
| Model | 6K.T1.0.000.2704 | |
| Manufacturer article number | 6KT100002704 | |
| Product type | Thermal motor overload relay | |
| Adjustable current setting range | 2.7–4 A | |
| Tripping class | Class 10A | |
| Compatible contactor families | Finder 6K.13 and 6K.14 | |
| Mounting method | Direct attachment to compatible contactor | |
| Normally open auxiliary contacts | 1 NO | |
| Normally closed auxiliary contacts | 1 NC | |
| Rated insulation voltage | 690 V | |
| Maximum rated operational voltage | 690 V | |
| Auxiliary contact material | AgNi | |
| Main circuit connection | Screw connection | |
| Terminal design | Box clamp | |
| Degree of protection | IP20 | |
| Reset functions | Manual push-button or automatic reset | |
| Stop function | Integrated stop button | |
| EAN | 8012823456782 |
The Finder 6K.T1.0.000.2704 is a thermal overload relay designed to help protect appropriately rated electric motors against sustained overload conditions when used with compatible Finder 6K.13 or 6K.14 contactors.
The relay has an adjustable current setting range of 2.7–4 A. The setting should be matched to the motor's rated current in accordance with the manufacturer's installation instructions.
The Finder 6K.T1.0.000.2704 is designed for Finder Series 6K.13 and 6K.14 industrial contactors and uses a direct-attachment mounting arrangement.
Yes. The relay supports manual push-button reset and automatic reset. The reset arrangement should be selected according to the application, with suitable precautions to prevent hazardous unintended motor restarting.
The relay includes one normally open (1 NO) and one normally closed (1 NC) auxiliary contact. These contacts can be used for overload signalling and interruption of the associated contactor control circuit when the relay trips.
Finder Series 6K thermal overload relays provide motor protection solutions for electrical panel manufacturers, machine builders, maintenance engineers and industrial automation professionals. Combining an adjustable 2.7–4 A current range, Class 10A thermal tripping, manual or automatic reset functionality and compatibility with Finder 6K.13 and 6K.14 contactors, the Finder 6K.T1.0.000.2704 supports dependable overload protection in professionally designed industrial motor starter systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.