Finder 6K.T1.0.000.2704 - 6K Series Industrial contactors

Finder 6K.T1.0.000.2704 – 6K Series Industrial contactors

Finder 6K.T1.0.000.2704 is a Class 10A thermal motor overload relay with an adjustable 2.7–4 A current setting range, one normally open and one normally closed auxiliary contact, manual or automatic reset capability and direct-mount compatibility with Finder 6K.13 and 6K.14 contactors.

SKU: 6K.T1.0.000.2704Alt SKU: 6KT100002704MPN: 6K.T1.0.000.2704
Price
List Price £65.35 ex VAT
Your Price (ex VAT) Save 35%
£42.48 35% OFF
You save £22.87 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £42.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£42.48

Why Choose the Finder 6K.T1.0.000.2704 Thermal Overload Relay?

The Finder 6K.T1.0.000.2704 is an adjustable 2.7–4 A thermal overload relay designed to protect electric motors against sustained overload conditions when used with compatible Finder Series 6K.13 and 6K.14 industrial contactors. Part of the Finder Series 6K motor control range, this device provides thermal motor protection for appropriately designed industrial motor starter assemblies.

Featuring a Class 10A thermal tripping characteristic, the Finder 6K.T1.0.000.2704 allows the overload current setting to be adjusted within its specified 2.7–4 A range. This enables the protection threshold to be selected according to the connected motor's rated current, helping reduce the risk of overheating caused by prolonged overcurrent conditions.

The relay incorporates one normally open and one normally closed auxiliary contact for overload signalling and control circuit interruption. With direct mounting compatibility, manual or automatic reset functionality, an integrated stop button and IP20 protection, it is suitable for incorporation into professionally designed industrial electrical control equipment.

Key Advantages

  • Adjustable 2.7–4 A current setting range for motor overload protection.
  • Class 10A thermal overload tripping for suitable motor starting and operating conditions.
  • Compatible with Finder 6K.13 and 6K.14 contactors.
  • Direct-attachment mounting for integration into compatible motor starter assemblies.
  • One normally open and one normally closed auxiliary contact for overload indication and control functions.
  • Manual push-button and automatic reset options for different control arrangements.
  • Integrated stop button for local control functionality.
  • 690 V maximum rated operational voltage.
  • IP20 degree of protection for installation inside suitable electrical enclosures.
  • Box-clamp terminals and screw connections for electrical wiring.
  • Helps protect appropriately rated motors against sustained overload conditions.

Key Features

  • Finder Series 6K thermal motor overload relay.
  • 2.7–4 A adjustable overload current setting.
  • Class 10A tripping classification.
  • Designed for Finder 6K.13 and 6K.14 contactors.
  • Direct-mount installation arrangement.
  • One normally open (1 NO) auxiliary contact.
  • One normally closed (1 NC) auxiliary contact.
  • Manual push-button reset.
  • Automatic reset capability.
  • Integrated stop button.
  • 690 V rated insulation voltage.
  • AgNi auxiliary contact material.
  • IP20 protection rating.
  • Screw-type main circuit connections.
  • Box-clamp terminal construction.

Reliable Thermal Motor Protection for Finder 6K Industrial Contactors

The Finder 6K.T1.0.000.2704 provides thermal overload protection for motors operated through compatible Finder 6K.13 and 6K.14 contactors. Its adjustable 2.7–4 A setting allows the relay to be configured according to the motor's rated current, helping protect motor windings and associated equipment against excessive heating caused by sustained overload conditions.

When the thermal overload relay trips, its auxiliary contacts change state. The normally closed auxiliary contact can be incorporated into the contactor control circuit to interrupt the coil supply, while the normally open auxiliary contact can provide an overload indication or fault signal to compatible monitoring equipment.

The relay's Class 10A tripping characteristic should be considered alongside the motor's full-load current, starting time and operating duty. Manual and automatic reset options provide flexibility when designing the control arrangement, although automatic reset must only be used where unintended restarting cannot create a hazard. The thermal overload relay does not replace short-circuit protection, so suitable upstream fuses or circuit breakers are also required.

Typical Applications

  • Industrial motor starter assemblies using Finder 6K.13 contactors.
  • Industrial motor starter assemblies using Finder 6K.14 contactors.
  • Three-phase electric motor overload protection.
  • Industrial pumps and pumping systems.
  • Conveyor and material handling equipment.
  • Fans and ventilation motor control.
  • Small industrial compressors and motor-driven machinery.
  • Automated production and manufacturing equipment.
  • Industrial electrical control panels.
  • Motor overload signalling and fault monitoring circuits.
  • OEM machinery and electrical panel manufacturing.
  • Maintenance and replacement of compatible thermal overload relays.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Contactor
Coil Type AC, AC/DC, DC
Manufacturer Finder
Series 6K
Model 6K.T1.0.000.2704
Manufacturer article number 6KT100002704
Product type Thermal motor overload relay
Adjustable current setting range 2.7–4 A
Tripping class Class 10A
Compatible contactor families Finder 6K.13 and 6K.14
Mounting method Direct attachment to compatible contactor
Normally open auxiliary contacts 1 NO
Normally closed auxiliary contacts 1 NC
Rated insulation voltage 690 V
Maximum rated operational voltage 690 V
Auxiliary contact material AgNi
Main circuit connection Screw connection
Terminal design Box clamp
Degree of protection IP20
Reset functions Manual push-button or automatic reset
Stop function Integrated stop button
EAN 8012823456782

Frequently Asked Questions

What is the Finder 6K.T1.0.000.2704 used for?

The Finder 6K.T1.0.000.2704 is a thermal overload relay designed to help protect appropriately rated electric motors against sustained overload conditions when used with compatible Finder 6K.13 or 6K.14 contactors.

What is the adjustable current range of the Finder 6K.T1.0.000.2704?

The relay has an adjustable current setting range of 2.7–4 A. The setting should be matched to the motor's rated current in accordance with the manufacturer's installation instructions.

Which Finder contactors are compatible with this overload relay?

The Finder 6K.T1.0.000.2704 is designed for Finder Series 6K.13 and 6K.14 industrial contactors and uses a direct-attachment mounting arrangement.

Does the Finder 6K.T1.0.000.2704 support manual and automatic reset?

Yes. The relay supports manual push-button reset and automatic reset. The reset arrangement should be selected according to the application, with suitable precautions to prevent hazardous unintended motor restarting.

What auxiliary contacts are included with the Finder 6K.T1.0.000.2704?

The relay includes one normally open (1 NO) and one normally closed (1 NC) auxiliary contact. These contacts can be used for overload signalling and interruption of the associated contactor control circuit when the relay trips.

Trusted by Industrial Automation Professionals Worldwide

Finder Series 6K thermal overload relays provide motor protection solutions for electrical panel manufacturers, machine builders, maintenance engineers and industrial automation professionals. Combining an adjustable 2.7–4 A current range, Class 10A thermal tripping, manual or automatic reset functionality and compatibility with Finder 6K.13 and 6K.14 contactors, the Finder 6K.T1.0.000.2704 supports dependable overload protection in professionally designed industrial motor starter systems.