Finder 6K.T1.0.000.1827 - 6K Series Industrial contactors

Finder 6K.T1.0.000.1827 – 6K Series Industrial contactors

Finder 6K.T1.0.000.1827 is a Class 10A thermal motor overload relay with an adjustable 1.8–2.7 A current setting range, one normally open and one normally closed auxiliary contact, selectable manual or automatic reset and direct-mount compatibility with Finder 6K.13 and 6K.14 contactors.

SKU: 6K.T1.0.000.1827Alt SKU: 6KT100001827MPN: 6K.T1.0.000.1827
Price
List Price £65.35 ex VAT
Your Price (ex VAT) Save 35%
£42.48 35% OFF
You save £22.87 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £42.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£42.48

Why Choose the Finder 6K.T1.0.000.1827 Thermal Overload Relay?

The Finder 6K.T1.0.000.1827 is an adjustable 1.8–2.7 A thermal overload relay designed to protect industrial electric motors against sustained overload conditions when used with compatible Finder Series 6K.13 and 6K.14 contactors. Part of the Finder Series 6K motor control range, this device provides thermal motor protection for appropriately designed industrial motor starter assemblies.

Featuring a Class 10A thermal tripping characteristic, the Finder 6K.T1.0.000.1827 allows the overload threshold to be adjusted within its specified 1.8–2.7 A current range. The relay incorporates one normally open and one normally closed auxiliary contact for overload signalling, control circuit interruption and fault indication.

Designed for direct attachment to compatible contactors, the relay features an adjustable connection pin spacing for use with Finder 6K.13 and 6K.14 models. Its manual or automatic reset selection, integrated stop button, IP20 protection rating and 690 V rated insulation voltage support integration into professionally designed industrial electrical control equipment.

Key Advantages

  • Adjustable 1.8–2.7 A current setting range for precise motor overload protection.
  • Class 10A thermal overload tripping for suitable motor starting and operating conditions.
  • Compatible with Finder 6K.13 and 6K.14 contactors.
  • Direct-mount design for integration into compatible motor starter assemblies.
  • Adjustable connection pin spacing accommodates the supported contactor types.
  • Manual or automatic reset selection to suit the intended control arrangement.
  • 1 NO + 1 NC auxiliary contacts for fault indication and control circuit interruption.
  • Integrated stop button for local control functionality.
  • IP20 degree of protection for installation inside suitable electrical enclosures.
  • AgNi auxiliary contact material for electrical switching functions.
  • Helps protect motors against prolonged overcurrent conditions when correctly selected and installed.

Key Features

  • Finder Series 6K thermal motor overload relay.
  • 1.8–2.7 A adjustable overload current setting.
  • Class 10A tripping classification.
  • Designed for Finder 6K.13 and 6K.14 contactors.
  • Direct-attachment mounting arrangement.
  • Adjustable connection pin spacing for contactor compatibility.
  • One normally open (1 NO) auxiliary contact.
  • One normally closed (1 NC) auxiliary contact.
  • Manual and automatic reset modes.
  • Integrated reset and stop buttons.
  • 690 V rated insulation voltage.
  • AgNi auxiliary contact material.
  • IP20 protection rating.
  • Box-clamp electrical terminals.
  • Operating ambient temperature range of −25 °C to +60 °C.

Reliable Thermal Motor Protection for Finder 6K Industrial Contactors

The Finder 6K.T1.0.000.1827 provides thermal overload protection for motors operated through compatible Finder 6K.13 and 6K.14 contactors. Its adjustable 1.8–2.7 A setting enables the relay to be configured according to the motor's rated current, helping reduce the risk of damage caused by sustained overload conditions.

When an overload causes the relay to trip, the auxiliary contacts change state. The normally closed contact (95–96) can be incorporated into the contactor coil control circuit to interrupt operation, while the normally open contact (97–98) can provide an overload indication or fault signal to compatible monitoring equipment.

The relay's Class 10A tripping characteristic should be considered alongside the motor's full-load current, starting duration and operating duty. The selectable manual or automatic reset function provides flexibility for the control arrangement, although automatic restarting must be prevented where it could create a hazard. This thermal overload relay does not provide short-circuit protection, so suitable upstream fuses or circuit breakers are also required.

Typical Applications

  • Industrial motor starter assemblies using Finder 6K.13 contactors.
  • Industrial motor starter assemblies using Finder 6K.14 contactors.
  • Three-phase electric motor overload protection.
  • Industrial pumps and pumping systems.
  • Conveyor and material handling equipment.
  • Fans and ventilation motor control.
  • Industrial compressors and motor-driven machinery.
  • Automated production and manufacturing equipment.
  • Industrial electrical control panels.
  • Motor overload signalling and fault monitoring circuits.
  • OEM machinery and electrical panel manufacturing.
  • Maintenance and replacement of compatible thermal overload relays.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Contactor
Coil Type AC, AC/DC, DC
Manufacturer Finder
Series 6K
Model 6K.T1.0.000.1827
Manufacturer article number 6KT100001827
Product type Thermal motor overload relay
Adjustable current setting range 1.8–2.7 A
Tripping class Class 10A
Compatible contactor families Finder 6K.13 and 6K.14
Mounting method Direct attachment to compatible contactor
Connection pin spacing Adjustable
Normally open auxiliary contacts 1 NO
Normally closed auxiliary contacts 1 NC
Rated insulation voltage 690 V
Maximum rated operational voltage 690 V
Auxiliary contact rated current (AC-15, 24 V) 3 A
Auxiliary contact rated current (AC-15, 230 V) 2 A
Auxiliary contact rated current (AC-15, 400 V) 1 A
Auxiliary contact rated current (DC-13, 24 V) 1 A
Auxiliary contact material AgNi
Main circuit connection Screw connection
Terminal design Box clamp
Degree of protection IP20
Ambient temperature range −25 °C to +60 °C
Reset functions Manual push-button or automatic reset
Stop function Integrated stop button
EAN 8012823456768

Frequently Asked Questions

What is the Finder 6K.T1.0.000.1827 used for?

The Finder 6K.T1.0.000.1827 is a thermal overload relay designed to help protect appropriately rated electric motors against sustained overload conditions when used with compatible Finder 6K.13 or 6K.14 contactors.

What is the adjustable current range of the Finder 6K.T1.0.000.1827?

The relay has an adjustable current setting range of 1.8–2.7 A. The setting should be matched to the motor's rated current in accordance with the manufacturer's installation instructions.

Which Finder contactors are compatible with this overload relay?

The Finder 6K.T1.0.000.1827 is designed for Finder Series 6K.13 and 6K.14 industrial contactors. It features adjustable connection pin spacing to accommodate these compatible contactor types.

Does the Finder 6K.T1.0.000.1827 support manual and automatic reset?

Yes. The relay supports manual push-button reset and automatic reset, allowing the reset arrangement to be selected for the application. Automatic reset should only be used where the control system prevents hazardous unintended restarting.

What auxiliary contacts are included with the Finder 6K.T1.0.000.1827?

The relay includes one normally open (1 NO) and one normally closed (1 NC) auxiliary contact. These contacts can be used for overload signalling and interruption of the associated contactor control circuit when the relay trips.

Trusted by Industrial Automation Professionals Worldwide

Finder Series 6K thermal overload relays provide motor protection solutions for electrical panel manufacturers, machine builders, maintenance engineers and industrial automation professionals. Combining an adjustable 1.8–2.7 A current range, Class 10A thermal tripping, selectable manual or automatic reset and compatibility with Finder 6K.13 and 6K.14 contactors, the Finder 6K.T1.0.000.1827 supports dependable overload protection in professionally designed industrial motor starter systems.