Finder 6K.T1.0.000.1318 is a Class 10A thermal overload relay with an adjustable 13–18 A current setting, one normally open and one normally closed auxiliary contact, manual or automatic reset and direct-mounting compatibility with Finder 6K.13 and 6K.14 industrial contactors.

SKU: 6K.T1.0.000.1318Alt SKU: 6KT100001318MPN: 6K.T1.0.000.1318
Price
List Price £76.15 ex VAT
Your Price (ex VAT) Save 35%
£49.50 35% OFF
You save £26.65 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £49.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£49.50

Why Choose the Finder 6K.T1.0.000.1318 Thermal Overload Relay?

The Finder 6K.T1.0.000.1318 is an adjustable thermal overload protection relay designed to protect industrial electric motors against sustained overload conditions. Part of the Finder 6K Series, this motor protection device is specifically designed for use with Finder 6K.13 and 6K.14 industrial contactors, providing an integrated solution for motor starter assemblies and industrial electrical control panels.

Featuring an adjustable current setting range of 13–18 A, the Finder 6K.T1.0.000.1318 enables motor overload protection to be matched to the connected motor's rated operating current. Its Class 10A tripping characteristic provides thermal overload response in accordance with the applicable IEC motor protection requirements, helping to reduce the risk of damage caused by excessive motor current.

The relay incorporates one normally open and one normally closed auxiliary contact, together with a stop button and manual or automatic reset functionality. Its direct-mounting arrangement, adjustable connection pins and IP20 protection rating make it a practical choice for industrial motor control installations using compatible Finder contactors.

Key Advantages

  • Adjustable 13–18 A current setting range for matching overload protection to the motor's rated current.
  • Class 10A thermal overload protection for suitable industrial motor applications.
  • Designed specifically for Finder 6K.13 and 6K.14 contactors.
  • Direct contactor mounting supports compact motor starter assemblies.
  • Manual and automatic reset options for flexible motor protection arrangements.
  • Integrated stop button for local operation.
  • One normally open and one normally closed auxiliary contact for trip indication and control functions.
  • AgNi auxiliary contact material for reliable control-circuit switching.
  • 690 V rated insulation voltage for industrial electrical applications.
  • IP20 protection rating for installation within suitable electrical enclosures.
  • Adjustable connection-pin arrangement for compatibility with the specified Finder contactor types.

Key Features

  • Finder 6K Series thermal overload relay.
  • Model: 6K.T1.0.000.1318.
  • Adjustable thermal current setting: 13–18 A.
  • Trip class: Class 10A.
  • Compatible contactors: Finder 6K.13 and 6K.14.
  • Direct-mounting design for compatible contactors.
  • One normally open (1 NO) auxiliary contact.
  • One normally closed (1 NC) auxiliary contact.
  • Manual reset functionality.
  • Automatic reset functionality.
  • Integrated stop button.
  • Adjustable overload current threshold.
  • Silver-nickel (AgNi) auxiliary contacts.
  • 690 V rated insulation voltage.
  • IP20 protection classification.
  • Screw-type main circuit connections with box-clamp terminals.
  • Adjustable connection-pin spacing for the compatible contactor arrangements.
  • Thermal overload protection designed in accordance with IEC 60947-4-1.

Adjustable Thermal Overload Protection for Industrial Motors

The Finder 6K.T1.0.000.1318 provides thermal overload protection by monitoring the current passing through the motor circuit. When an overload condition persists beyond the relay's thermal operating characteristic, the device trips and changes the state of its auxiliary contacts. When correctly wired into the contactor control circuit, this action causes the contactor to release, disconnecting the motor from its power supply.

The 13–18 A adjustable setting range allows the protection threshold to be selected according to the motor nameplate current and installation requirements. Its Class 10A trip characteristic, manual or automatic reset options and integrated stop button provide flexibility for industrial motor starter designs. The relay is intended for overload protection and must be used alongside appropriately selected short-circuit protective devices.

Typical Applications

  • Thermal overload protection for three-phase industrial motors.
  • Finder 6K.13 and 6K.14 contactor-based motor starters.
  • Industrial motor control centres and electrical control panels.
  • Conveyor systems and material handling equipment.
  • Pumps and water treatment motor control installations.
  • Industrial ventilation and fan motor protection.
  • Manufacturing machinery and automated production equipment.
  • Compressor and mechanical drive motor control systems.
  • OEM industrial machinery requiring adjustable motor overload protection.
  • Industrial automation systems requiring overload trip signalling.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Contactor
Coil Type AC, AC/DC, DC
Manufacturer Finder
Series 6K
Model 6K.T1.0.000.1318
Manufacturer article number 6KT100001318
Product type Thermal overload relay
Protection function Motor thermal overload protection
Adjustable current range 13–18 A
Tripping class Class 10A
Compatible contactor series Finder 6K.13 and 6K.14
Mounting method Direct mounting to compatible contactors
Auxiliary normally open contacts 1
Auxiliary normally closed contacts 1
Auxiliary contact material AgNi (silver-nickel)
Rated insulation voltage 690 V
Maximum rated operational voltage 690 V
Reset modes Manual and automatic
Local stop button Yes
Reset button Yes
Main circuit connection Screw connection with box-clamp terminals
Protection rating IP20
Applicable standard IEC 60947-4-1
EAN / GTIN-13 8012823456881
Product category Thermal Overload Relays / Motor Protection Relays

Frequently Asked Questions

What is the Finder 6K.T1.0.000.1318 used for?

The Finder 6K.T1.0.000.1318 is a thermal overload relay designed to protect industrial electric motors against sustained overload conditions. It is intended for use with compatible Finder 6K.13 and 6K.14 contactors.

What is the adjustable current range of this overload relay?

The relay has an adjustable overload current setting range of 13–18 A, allowing the protection threshold to be matched to a suitable motor's rated current.

Which Finder contactors are compatible with the 6K.T1.0.000.1318?

The Finder 6K.T1.0.000.1318 is designed for direct mounting to Finder 6K.13 and 6K.14 industrial contactors. Its connection-pin arrangement can be adjusted for the compatible contactor types.

What does Class 10A mean on this thermal overload relay?

Class 10A identifies the relay's thermal overload tripping characteristic under standardised test conditions. It is intended for suitable motor starting applications and should be selected according to the motor's starting time and operating requirements.

Does the Finder 6K.T1.0.000.1318 support manual and automatic reset?

Yes. The relay supports manual and automatic reset modes, allowing the reset arrangement to be selected according to the motor control system's requirements. Automatic reset should only be used where unexpected motor restarting cannot create a hazard.

How many auxiliary contacts does this overload relay have?

The Finder 6K.T1.0.000.1318 includes one normally open (1 NO) and one normally closed (1 NC) auxiliary contact for overload trip indication, contactor control and signalling circuits.

Does this relay have a stop button?

Yes. The Finder 6K.T1.0.000.1318 incorporates a stop button for local operation, together with its reset functionality.

Does the Finder 6K.T1.0.000.1318 provide short-circuit protection?

No. This device provides thermal overload protection and is not a substitute for a fuse or circuit breaker. Suitable short-circuit protection must be provided separately according to the electrical installation and motor starter design.

What is the rated insulation voltage of the Finder 6K.T1.0.000.1318?

The relay has a 690 V rated insulation voltage and is intended for use within its specified electrical ratings.

What is the difference between a thermal overload relay and a contactor?

A contactor electrically switches a motor or other load on and off, while a thermal overload relay detects sustained excessive motor current and provides a trip signal to the control circuit. The two devices are commonly used together in a motor starter assembly.

Trusted by Industrial Motor Control and Electrical Engineering Professionals

Finder 6K Series thermal overload relays are designed for electrical engineers, industrial automation specialists, panel builders and machinery manufacturers requiring adjustable motor overload protection, dependable trip signalling and direct integration with compatible industrial contactors.