Finder 6K.T1.0.000.1014 is an adjustable 10–14 A Class 10A thermal overload relay featuring manual and automatic reset, one normally open and one normally closed auxiliary contact, a maximum rated operational voltage of 690 V AC and direct mounting compatibility with Finder 6K.13 and 6K.14 contactors for industrial motor protection.
£49.50
The Finder 6K.T1.0.000.1014 is an adjustable thermal overload relay for three-phase motor protection, designed to help protect industrial electric motors against sustained overcurrent and excessive heating. Part of the Finder 6K Series, this motor protection relay is specifically designed for integration with Finder 6K.13 and 6K.14 industrial contactors, providing a practical solution for motor starters, industrial machinery and electrical control panels.
Featuring an adjustable current setting range of 10–14 A, the Finder 6K.T1.0.000.1014 enables overload protection to be matched to the rated current of the connected motor. Its Class 10A thermal trip characteristic is suitable for many conventional motor starting applications, while the integrated normally open and normally closed auxiliary contacts provide convenient overload signalling and contactor control functionality.
With a maximum rated operational voltage of 690 V AC, selectable manual or automatic reset, an integrated stop button and IP20 protection, this Finder thermal overload relay is designed for dependable use in industrial motor control assemblies. Direct mounting onto compatible Finder contactors, together with adjustable connection pin spacing, simplifies installation and helps create compact, coordinated motor starter systems.
The Finder 6K.T1.0.000.1014 is designed to protect electric motors from sustained overload currents that may otherwise cause excessive heating, insulation deterioration and premature motor failure. Its thermal protection mechanism responds to the current flowing through the motor circuit, operating when an overload persists beyond the permitted time determined by the relay's trip characteristic.
The relay's 10–14 A adjustable setting range allows an installer to select a current threshold appropriate to the connected motor. For effective protection, the setting should be chosen using the motor nameplate current and the manufacturer's application guidance rather than simply selecting the highest available value.
Its Class 10A trip characteristic provides an inverse-time overload response suited to many conventional industrial motor starting duties. This means the relay can accommodate suitable short-duration starting currents while responding to sustained overloads that could damage the motor. Motors with unusually long starting times or demanding operating cycles may require a different protection arrangement.
When an overload occurs, the relay's normally closed auxiliary contact can be used to open the associated contactor control circuit, disconnecting the motor supply through the contactor. The normally open auxiliary contact can provide a fault signal to a control panel indicator, alarm circuit or suitably designed PLC input.
The manual and automatic reset functions provide flexibility in how the motor control system responds after a trip. Manual reset requires deliberate operator intervention, while automatic reset allows the thermal mechanism to reset following recovery. Automatic reset should only be used where an unexpected motor restart cannot create a hazard.
Designed for direct mounting onto Finder 6K.13 and 6K.14 industrial contactors, the relay includes adjustable connection pin spacing to suit the compatible contactor arrangements. This simplifies motor starter assembly and reduces the need for separate wiring between the contactor and overload protection device.
As a thermal overload relay, the Finder 6K.T1.0.000.1014 does not replace short-circuit protection. It should be used with an appropriately selected contactor and suitable fuses or circuit breakers, with the complete assembly designed according to the motor characteristics, electrical installation requirements and applicable safety standards.
Tick the specs you need, then view products that match.
| Terminal Type | Spring clamp | |
|---|---|---|
| Device Type | Contactor | |
| Coil Type | AC, AC/DC, DC | |
| Manufacturer | Finder | |
| Series | 6K Series | |
| Model | 6K.T1.0.000.1014 | |
| Manufacturer article number | 6KT100001014 | |
| Product type | Thermal overload relay | |
| Relay type | 6K.T1 | |
| Protection function | Thermal motor overload protection | |
| Adjustable current range | 10–14 A | |
| Minimum current setting | 10 A | |
| Maximum current setting | 14 A | |
| Trip class | Class 10A | |
| Maximum rated operational voltage (Ue) | 690 V AC | |
| Rated insulation voltage | 690 V | |
| Auxiliary contact configuration | 1 normally open (NO) + 1 normally closed (NC) | |
| Auxiliary contact material | Silver nickel (AgNi) | |
| Reset function | Selectable manual / automatic | |
| Local reset button | Yes | |
| Automatic reset | Yes | |
| Remote electrical reset input | No | |
| Stop button | Integrated | |
| Protection rating | IP20 | |
| Mounting type | Direct contactor mounting | |
| Compatible contactors | Finder 6K.13 and 6K.14 | |
| Connection type | Screw-type cage clamp terminals | |
| Connection pin spacing | Adjustable for compatible contactors | |
| Maximum rigid conductor cross-section | 6 mm² | |
| Maximum flexible conductor cross-section | 4 mm² | |
| Height | 74 mm | |
| Depth | 104.5 mm | |
| Maximum operating temperature | +60 °C | |
| Applicable standard | IEC/EN 60947-4-1 | |
| EAN | 8012823456867 |
The Finder 6K.T1.0.000.1014 is a thermal overload relay designed to protect industrial electric motors against sustained overcurrent conditions. It is intended for use with compatible Finder 6K.13 and 6K.14 contactors in motor starter assemblies.
The relay has an adjustable current setting range of 10–14 A. The correct setting should be selected according to the connected motor's rated current and the applicable motor protection requirements.
The Finder 6K.T1.0.000.1014 is designed for direct mounting onto Finder 6K.13 and 6K.14 industrial contactors. Its adjustable connection pin spacing helps accommodate these compatible contactor configurations.
Class 10A is a thermal overload trip classification defined by IEC/EN 60947-4-1. It describes the relay's overload tripping behaviour and is suitable for many standard motor starting applications where the starting characteristics are compatible with this trip class.
The relay has a maximum rated operational voltage of 690 V AC, allowing use in appropriately designed industrial motor control installations within its specified electrical ratings.
Yes. The relay supports selectable manual and automatic reset modes. Manual reset requires operator intervention after an overload trip, while automatic reset allows the relay to reset after thermal recovery. Automatic reset must only be used where unexpected motor restarting cannot create a safety hazard.
The relay includes one normally open (NO) and one normally closed (NC) auxiliary contact. These contacts can be used for contactor control, overload trip signalling, fault indication and industrial automation feedback.
No. The Finder 6K.T1.0.000.1014 is a thermal overload protection device rather than an electromagnetic contactor. It operates through a thermal mechanism responding to motor current and does not require a separate operating coil.
No. This relay provides thermal overload protection and is not a substitute for short-circuit protection. Appropriately rated fuses or circuit breakers must be used as part of the complete motor protection system.
Both devices belong to the Finder 6K.T1 thermal overload relay series and are designed for compatible Finder 6K.13 and 6K.14 contactors. The main difference is the adjustable current range: the 6K.T1.0.000.1014 covers 10–14 A, while the 6K.T1.0.000.0811 covers 8–11 A. The correct model should be selected according to the motor's rated current.
Finder 6K Series thermal overload relays provide dependable motor protection for industrial automation, electrical control panels and machinery applications. With an adjustable 10–14 A current range, Class 10A thermal protection, selectable manual or automatic reset and direct compatibility with Finder 6K.13 and 6K.14 contactors, the Finder 6K.T1.0.000.1014 offers a practical solution for electrical engineers, panel builders and OEM machinery manufacturers requiring reliable industrial motor overload protection.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.