Finder 6K.T1.0.000.1014 is an adjustable 10–14 A Class 10A thermal overload relay featuring manual and automatic reset, one normally open and one normally closed auxiliary contact, a maximum rated operational voltage of 690 V AC and direct mounting compatibility with Finder 6K.13 and 6K.14 contactors for industrial motor protection.

SKU: 6K.T1.0.000.1014Alt SKU: 6KT100001014MPN: 6K.T1.0.000.1014
Price
List Price £76.15 ex VAT
Your Price (ex VAT) Save 35%
£49.50 35% OFF
You save £26.65 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £49.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£49.50

Why Choose the Finder 6K.T1.0.000.1014 Thermal Overload Relay?

The Finder 6K.T1.0.000.1014 is an adjustable thermal overload relay for three-phase motor protection, designed to help protect industrial electric motors against sustained overcurrent and excessive heating. Part of the Finder 6K Series, this motor protection relay is specifically designed for integration with Finder 6K.13 and 6K.14 industrial contactors, providing a practical solution for motor starters, industrial machinery and electrical control panels.

Featuring an adjustable current setting range of 10–14 A, the Finder 6K.T1.0.000.1014 enables overload protection to be matched to the rated current of the connected motor. Its Class 10A thermal trip characteristic is suitable for many conventional motor starting applications, while the integrated normally open and normally closed auxiliary contacts provide convenient overload signalling and contactor control functionality.

With a maximum rated operational voltage of 690 V AC, selectable manual or automatic reset, an integrated stop button and IP20 protection, this Finder thermal overload relay is designed for dependable use in industrial motor control assemblies. Direct mounting onto compatible Finder contactors, together with adjustable connection pin spacing, simplifies installation and helps create compact, coordinated motor starter systems.

Key Advantages

  • Adjustable 10–14 A current range enables accurate matching to suitable motor full-load currents.
  • Class 10A thermal trip characteristic provides overload protection for standard motor starting applications.
  • Direct compatibility with Finder 6K.13 and 6K.14 contactors simplifies motor starter assembly.
  • Maximum rated operational voltage of 690 V AC supports industrial motor control installations.
  • Manual and automatic reset options provide flexibility for different control and safety requirements.
  • Integrated stop button provides convenient local control functionality.
  • One normally open and one normally closed auxiliary contact enables overload trip indication and control circuit interruption.
  • Silver nickel (AgNi) auxiliary contacts support reliable electrical signalling.
  • Adjustable connection pin spacing accommodates compatible Finder contactor configurations.
  • Screw-type cage clamp terminals provide secure electrical connections.
  • IP20 protection rating for installation inside appropriately protected electrical enclosures.
  • Helps reduce the risk of motor damage and production downtime caused by sustained electrical overloads.

Key Features

  • Finder 6K.T1 Series thermal overload relay.
  • 10–14 A adjustable motor current setting.
  • Class 10A overload trip classification.
  • 690 V AC maximum rated operational voltage.
  • Three-phase thermal motor overload protection.
  • Selectable manual or automatic reset following an overload trip.
  • Integrated reset button for local resetting.
  • Integrated stop button for motor control circuit operation.
  • 1 NO + 1 NC auxiliary contact configuration.
  • Silver nickel (AgNi) auxiliary contact material.
  • Direct mounting onto Finder 6K.13 and 6K.14 contactors.
  • Adjustable connection pin spacing for compatible contactors.
  • Screw-type cage clamp terminal connections.
  • IP20 enclosure protection rating.
  • Designed for use in industrial motor protection systems in accordance with IEC/EN 60947-4-1.

Reliable Thermal Overload Protection for Industrial Motor Control

The Finder 6K.T1.0.000.1014 is designed to protect electric motors from sustained overload currents that may otherwise cause excessive heating, insulation deterioration and premature motor failure. Its thermal protection mechanism responds to the current flowing through the motor circuit, operating when an overload persists beyond the permitted time determined by the relay's trip characteristic.

The relay's 10–14 A adjustable setting range allows an installer to select a current threshold appropriate to the connected motor. For effective protection, the setting should be chosen using the motor nameplate current and the manufacturer's application guidance rather than simply selecting the highest available value.

Its Class 10A trip characteristic provides an inverse-time overload response suited to many conventional industrial motor starting duties. This means the relay can accommodate suitable short-duration starting currents while responding to sustained overloads that could damage the motor. Motors with unusually long starting times or demanding operating cycles may require a different protection arrangement.

When an overload occurs, the relay's normally closed auxiliary contact can be used to open the associated contactor control circuit, disconnecting the motor supply through the contactor. The normally open auxiliary contact can provide a fault signal to a control panel indicator, alarm circuit or suitably designed PLC input.

The manual and automatic reset functions provide flexibility in how the motor control system responds after a trip. Manual reset requires deliberate operator intervention, while automatic reset allows the thermal mechanism to reset following recovery. Automatic reset should only be used where an unexpected motor restart cannot create a hazard.

Designed for direct mounting onto Finder 6K.13 and 6K.14 industrial contactors, the relay includes adjustable connection pin spacing to suit the compatible contactor arrangements. This simplifies motor starter assembly and reduces the need for separate wiring between the contactor and overload protection device.

As a thermal overload relay, the Finder 6K.T1.0.000.1014 does not replace short-circuit protection. It should be used with an appropriately selected contactor and suitable fuses or circuit breakers, with the complete assembly designed according to the motor characteristics, electrical installation requirements and applicable safety standards.

Typical Applications

  • Three-phase industrial motor overload protection.
  • Direct-on-line (DOL) motor starter assemblies.
  • Industrial pumps and water treatment equipment.
  • Ventilation fans and HVAC motor control systems.
  • Conveyor systems and material handling machinery.
  • Industrial compressors and processing equipment.
  • Manufacturing and production line machinery.
  • Packaging and automated processing equipment.
  • Electrical control panels and motor control centres.
  • Motor starters using Finder 6K.13 and 6K.14 contactors.
  • PLC-monitored motor overload fault indication circuits.
  • OEM machinery and industrial electrical panel manufacturing.

Technical Specifications

Tick the specs you need, then view products that match.

Terminal Type Spring clamp
Device Type Contactor
Coil Type AC, AC/DC, DC
Manufacturer Finder
Series 6K Series
Model 6K.T1.0.000.1014
Manufacturer article number 6KT100001014
Product type Thermal overload relay
Relay type 6K.T1
Protection function Thermal motor overload protection
Adjustable current range 10–14 A
Minimum current setting 10 A
Maximum current setting 14 A
Trip class Class 10A
Maximum rated operational voltage (Ue) 690 V AC
Rated insulation voltage 690 V
Auxiliary contact configuration 1 normally open (NO) + 1 normally closed (NC)
Auxiliary contact material Silver nickel (AgNi)
Reset function Selectable manual / automatic
Local reset button Yes
Automatic reset Yes
Remote electrical reset input No
Stop button Integrated
Protection rating IP20
Mounting type Direct contactor mounting
Compatible contactors Finder 6K.13 and 6K.14
Connection type Screw-type cage clamp terminals
Connection pin spacing Adjustable for compatible contactors
Maximum rigid conductor cross-section 6 mm²
Maximum flexible conductor cross-section 4 mm²
Height 74 mm
Depth 104.5 mm
Maximum operating temperature +60 °C
Applicable standard IEC/EN 60947-4-1
EAN 8012823456867

Frequently Asked Questions

What is the Finder 6K.T1.0.000.1014 used for?

The Finder 6K.T1.0.000.1014 is a thermal overload relay designed to protect industrial electric motors against sustained overcurrent conditions. It is intended for use with compatible Finder 6K.13 and 6K.14 contactors in motor starter assemblies.

What is the adjustable current range of the Finder 6K.T1.0.000.1014?

The relay has an adjustable current setting range of 10–14 A. The correct setting should be selected according to the connected motor's rated current and the applicable motor protection requirements.

Which Finder contactors are compatible with this thermal overload relay?

The Finder 6K.T1.0.000.1014 is designed for direct mounting onto Finder 6K.13 and 6K.14 industrial contactors. Its adjustable connection pin spacing helps accommodate these compatible contactor configurations.

What does Class 10A mean on the Finder 6K.T1.0.000.1014?

Class 10A is a thermal overload trip classification defined by IEC/EN 60947-4-1. It describes the relay's overload tripping behaviour and is suitable for many standard motor starting applications where the starting characteristics are compatible with this trip class.

What is the maximum operating voltage of the Finder 6K.T1.0.000.1014?

The relay has a maximum rated operational voltage of 690 V AC, allowing use in appropriately designed industrial motor control installations within its specified electrical ratings.

Does the Finder 6K.T1.0.000.1014 support manual and automatic reset?

Yes. The relay supports selectable manual and automatic reset modes. Manual reset requires operator intervention after an overload trip, while automatic reset allows the relay to reset after thermal recovery. Automatic reset must only be used where unexpected motor restarting cannot create a safety hazard.

How many auxiliary contacts does the Finder 6K.T1.0.000.1014 have?

The relay includes one normally open (NO) and one normally closed (NC) auxiliary contact. These contacts can be used for contactor control, overload trip signalling, fault indication and industrial automation feedback.

Does the Finder 6K.T1.0.000.1014 require a control coil?

No. The Finder 6K.T1.0.000.1014 is a thermal overload protection device rather than an electromagnetic contactor. It operates through a thermal mechanism responding to motor current and does not require a separate operating coil.

Can the Finder 6K.T1.0.000.1014 protect against short circuits?

No. This relay provides thermal overload protection and is not a substitute for short-circuit protection. Appropriately rated fuses or circuit breakers must be used as part of the complete motor protection system.

What is the difference between the Finder 6K.T1.0.000.1014 and the 6K.T1.0.000.0811?

Both devices belong to the Finder 6K.T1 thermal overload relay series and are designed for compatible Finder 6K.13 and 6K.14 contactors. The main difference is the adjustable current range: the 6K.T1.0.000.1014 covers 10–14 A, while the 6K.T1.0.000.0811 covers 8–11 A. The correct model should be selected according to the motor's rated current.

Trusted by Industrial Automation Professionals Worldwide

Finder 6K Series thermal overload relays provide dependable motor protection for industrial automation, electrical control panels and machinery applications. With an adjustable 10–14 A current range, Class 10A thermal protection, selectable manual or automatic reset and direct compatibility with Finder 6K.13 and 6K.14 contactors, the Finder 6K.T1.0.000.1014 offers a practical solution for electrical engineers, panel builders and OEM machinery manufacturers requiring reliable industrial motor overload protection.