Finder 6K.T1.0.000.0811 - 6K Series Industrial contactors

Finder 6K.T1.0.000.0811 – 6K Series Industrial contactors

Finder 6K.T1.0.000.0811 is an adjustable 8–11 A Class 10A thermal overload relay featuring manual and automatic reset, 1 NO and 1 NC auxiliary contacts, a maximum operating voltage of 690 V AC and direct mounting compatibility with Finder 6K.13 and 6K.14 contactors for industrial motor protection.

SKU: 6K.T1.0.000.0811Alt SKU: 6KT100000811MPN: 6K.T1.0.000.0811
Price
List Price £76.15 ex VAT
Your Price (ex VAT) Save 35%
£49.50 35% OFF
You save £26.65 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £49.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£49.50

Why Choose the Finder 6K.T1.0.000.0811 Thermal Overload Relay?

The Finder 6K.T1.0.000.0811 is a reliable and adjustable thermal overload relay for three-phase motor protection, designed to protect industrial electric motors against sustained overload conditions. As part of the Finder 6K Series motor protection range, this relay is specifically developed for use with Finder 6K.13 and 6K.14 industrial contactors, providing an integrated solution for motor starters and industrial automation systems.

Featuring an adjustable current setting range of 8–11 A, the relay allows motor protection to be matched to the connected motor's rated current. Its Class 10A thermal trip characteristic provides overload protection suitable for many standard industrial motor starting applications. Integrated manual and automatic reset options, a stop button and auxiliary signalling contacts simplify operation, fault indication and maintenance.

With a maximum rated operational voltage of 690 V AC, IP20 protection rating and direct mounting compatibility with Finder 6K.13 and 6K.14 contactors, the Finder 6K.T1.0.000.0811 is suitable for industrial motor starter assemblies, pumps, fans, conveyors and manufacturing machinery. Its compact construction enables efficient installation inside electrical control panels while providing dependable motor overload protection.

Key Advantages

  • Reliable thermal overload protection for industrial three-phase motors.
  • Adjustable 8–11 A current setting range allows protection to be matched to the motor's rated current.
  • Class 10A trip characteristic for standard motor starting and overload protection applications.
  • Direct mounting compatibility with Finder 6K.13 and 6K.14 contactors.
  • Manual and automatic reset options provide flexibility for different motor control requirements.
  • Integrated stop button for local operation of the motor control circuit.
  • One normally open (NO) and one normally closed (NC) auxiliary contact for signalling and control.
  • Silver nickel (AgNi) contact material supports dependable auxiliary contact operation.
  • 690 V AC maximum rated operational voltage for industrial electrical systems.
  • IP20 protection rating suitable for installation inside appropriately protected electrical enclosures.
  • Compact design with adjustable connection spacing for compatible Finder contactors.
  • Helps reduce the risk of motor damage caused by sustained electrical overloads.

Key Features

  • Finder 6K.T1 thermal overload relay series.
  • 8–11 A adjustable motor current setting.
  • Class 10A thermal overload trip classification.
  • Maximum rated operational voltage of 690 V AC.
  • Three-phase motor overload protection using a thermal trip mechanism.
  • Manual or automatic reset selection following an overload trip.
  • Integrated reset button for local fault resetting.
  • Integrated stop button for control circuit operation.
  • 1 NO + 1 NC auxiliary contact configuration.
  • Silver nickel (AgNi) auxiliary contact material.
  • Direct mounting onto Finder 6K.13 and 6K.14 contactors.
  • Adjustable connection pin spacing for compatible contactor configurations.
  • Screw-type cage clamp terminals for secure electrical connections.
  • IP20 protection rating.
  • Designed for motor overload protection applications in accordance with IEC/EN 60947-4-1.

Reliable Thermal Overload Protection for Industrial Motors

Thermal overload relays such as the Finder 6K.T1.0.000.0811 protect electric motors against sustained overcurrent conditions that can cause excessive heating and damage to motor windings. The relay monitors the current flowing through the motor circuit and uses a thermal trip mechanism to respond when the current exceeds the selected overload setting for a sufficient period.

The 8–11 A adjustable current range allows the relay to be configured according to the motor's rated full-load current. This flexibility makes it suitable for a range of industrial motors where the required overload setting falls within the relay's adjustment range. Correct adjustment is essential to ensure appropriate protection while avoiding unnecessary motor interruptions.

The Class 10A trip characteristic is designed for standard motor starting applications. Thermal overload protection uses an inverse-time response, meaning higher overload currents generally cause faster tripping. This helps protect motors against prolonged overloads while accommodating normal starting current for suitably selected applications.

When an overload condition occurs, the relay's normally closed auxiliary contact can interrupt the associated contactor control circuit, causing the contactor to disconnect the motor supply. The normally open auxiliary contact can be used to provide a trip indication to a control panel, alarm circuit or programmable logic controller.

The Finder 6K.T1 Series supports manual and automatic reset modes, allowing the motor control system to be configured according to operational and safety requirements. Manual reset requires deliberate intervention after an overload trip, while automatic reset permits the relay to reset after the thermal mechanism has recovered. Automatic reset should only be selected where unexpected motor restarting cannot create a hazard.

Designed for direct integration with Finder 6K.13 and 6K.14 industrial contactors, the relay includes adjustable connection spacing to accommodate compatible contactor configurations. This enables the creation of compact motor starter assemblies with coordinated switching and overload protection functions.

The Finder 6K.T1.0.000.0811 provides thermal overload protection rather than standalone short-circuit protection. It must therefore be installed with appropriately rated contactors and short-circuit protective devices, such as fuses or circuit breakers, selected according to the motor installation and applicable electrical standards.

Typical Applications

  • Three-phase industrial motor overload protection.
  • Direct-on-line (DOL) motor starter assemblies.
  • Industrial pumps and water treatment systems.
  • Ventilation fans and HVAC motor control equipment.
  • Conveyor systems and material handling machinery.
  • Industrial compressors and processing equipment.
  • Manufacturing and production line machinery.
  • Packaging and automated processing equipment.
  • Electrical control panels and motor control cabinets.
  • Motor starter assemblies using Finder 6K.13 and 6K.14 contactors.
  • PLC-monitored motor protection and fault indication circuits.
  • OEM industrial machinery and electrical panel manufacturing.

Technical Specifications

Tick the specs you need, then view products that match.

Terminal Type Spring clamp
Device Type Contactor
Coil Type AC, AC/DC, DC
Manufacturer Finder
Series 6K Series Thermal Overload Protection
Model 6K.T1.0.000.0811
Product type Thermal overload relay / motor protection relay
Relay type 6K.T1
Protection function Thermal motor overload protection
Adjustable current range 8–11 A
Minimum current setting 8 A
Maximum current setting 11 A
Trip class Class 10A
Maximum rated operational voltage (Ue) 690 V AC
Rated insulation voltage 690 V
Auxiliary contact configuration 1 normally open (NO) + 1 normally closed (NC)
Auxiliary contact material Silver nickel (AgNi)
Reset function Manual / automatic selectable
Reset button Integrated
Stop button Integrated
Remote electrical reset input Not provided
Protection rating IP20
Mounting type Direct mounting onto compatible contactors
Compatible contactor types Finder 6K.13 and 6K.14
Connection type Screw-type cage clamp terminals
Minimum rigid conductor cross-section 0.75 mm²
Maximum rigid conductor cross-section 6 mm²
Flexible conductor cross-section 1–4 mm²
Operating temperature −25 to +60 °C
Dimensions (W × H × D) 45 × 74 × 104.5 mm
Width 45 mm
Height 74 mm
Depth 104.5 mm
Product colour Grey / black
Applicable standard IEC/EN 60947-4-1
EAN 8012823456843

Frequently Asked Questions

What is the Finder 6K.T1.0.000.0811 used for?

The Finder 6K.T1.0.000.0811 is a thermal overload relay used to protect three-phase industrial motors against sustained electrical overload conditions. It is designed for use with compatible Finder 6K.13 and 6K.14 contactors in industrial motor starter assemblies.

What is the adjustable current range of the Finder 6K.T1.0.000.0811?

The relay features an adjustable current setting range of 8–11 A. The overload setting should be selected according to the connected motor's rated current and the applicable motor protection requirements.

Which Finder contactors are compatible with this thermal overload relay?

The Finder 6K.T1.0.000.0811 is designed for direct mounting onto Finder 6K.13 and 6K.14 industrial contactors. Its adjustable connection pin spacing supports integration with these compatible contactor types.

What does Class 10A mean on a thermal overload relay?

Class 10A is a thermal overload trip classification defined by IEC/EN 60947-4-1. It specifies a relatively fast overload response suitable for many standard motor starting applications, with tripping performance determined by the overload current and the relay's thermal condition.

What is the maximum operating voltage of the Finder 6K.T1.0.000.0811?

The relay has a maximum rated operational voltage of 690 V AC, making it suitable for appropriately designed industrial motor control systems operating within its specified electrical ratings.

Does the Finder 6K.T1.0.000.0811 support manual and automatic reset?

Yes. The relay supports selectable manual and automatic reset modes. Manual reset requires intervention following an overload trip, while automatic reset allows the relay to reset after cooling. Automatic reset must only be used where unintended motor restarting cannot create a safety risk.

How many auxiliary contacts does the Finder 6K.T1.0.000.0811 have?

The relay includes one normally open (NO) and one normally closed (NC) auxiliary contact. These contacts can be used for contactor control, overload trip signalling, alarm circuits and automation system feedback.

Does this thermal overload relay require a separate control coil?

No. The Finder 6K.T1.0.000.0811 is a thermal overload protection device and does not require a separate electromagnetic operating coil. It responds to motor current through its thermal mechanism and operates auxiliary contacts when an overload trip occurs.

Can the Finder 6K.T1.0.000.0811 protect against short circuits?

No. The relay provides thermal overload protection and is not a substitute for short-circuit protection. Appropriate fuses or circuit breakers must be installed to provide short-circuit protection in accordance with the electrical installation requirements.

What is the difference between the Finder 6K.T1.0.000.0811 and 6K.T1.0.000.1014?

Both devices belong to the Finder 6K.T1 thermal overload relay series and are designed for compatible Finder 6K.13 and 6K.14 contactors. The main difference is the adjustable current range: the 6K.T1.0.000.0811 covers 8–11 A, while the 6K.T1.0.000.1014 covers 10–14 A. The correct relay should be selected according to the motor's rated current.

Trusted by Industrial Automation Professionals Worldwide

Finder 6K Series thermal overload relays provide dependable motor protection for industrial automation, electrical control panels and machinery applications. With an adjustable 8–11 A current range, Class 10A thermal protection, manual and automatic reset options and direct compatibility with Finder 6K.13 and 6K.14 contactors, the Finder 6K.T1.0.000.0811 offers a practical solution for electrical engineers, panel builders and OEM machinery manufacturers requiring reliable industrial motor overload protection.