Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 6K.T1.0.000.0609 thermal overload relay with an adjustable 6–9 A current range, Class 10A trip characteristic, manual or automatic reset and 1 NO plus 1 NC auxiliary contacts, designed for motor protection with Finder 6K.13 and 6K.14 industrial contactors.
£49.50
The Finder 6K.T1.0.000.0609 is a reliable thermal overload protection relay designed to protect industrial electric motors against sustained overcurrent and excessive thermal loading. As part of the Finder 6K Series motor control and protection range, it is specifically developed for use with Finder 6K.13 and 6K.14 industrial contactors, providing an integrated motor protection solution for industrial machinery, electrical control panels and automation systems.
This thermal overload relay uses a thermal operating mechanism to respond to prolonged motor overload conditions. When the current exceeds the selected protection setting for the applicable trip period, the relay operates its auxiliary contacts, allowing the associated contactor control circuit to disconnect the motor. Its adjustable current setting, manual or automatic reset functionality and integrated stop button provide practical protection and control features for industrial motor starter assemblies.
Featuring an adjustable current setting range of 6–9 A, a Class 10A trip characteristic and a rated insulation voltage of 690 V, the Finder 6K.T1.0.000.0609 is suitable for protecting appropriately rated industrial motors. Its 1 normally open (NO) and 1 normally closed (NC) auxiliary contact arrangement, direct-mounting construction and IP20 protection rating support straightforward integration into industrial motor control systems.
Thermal overload relays such as the Finder 6K.T1.0.000.0609 protect electric motors by responding to sustained current levels that exceed the selected protection setting. The relay uses a thermal operating mechanism to detect overload conditions and changes the state of its auxiliary contacts when the applicable trip characteristic is reached. When correctly connected within a motor starter control circuit, this action can de-energise the associated contactor and disconnect the motor supply, helping reduce the risk of overheating and damage to motor windings.
The Finder 6K.T1 Series is designed for integration with Finder industrial contactors, creating coordinated motor switching and overload protection assemblies. The 6–9 A adjustable setting range allows the relay to be configured according to the motor's nameplate full-load current, while the Class 10A trip characteristic supports suitable motor starting and operating conditions. Manual reset allows an overload event to be investigated before operation resumes, while automatic reset is available where the control system and machinery safety requirements permit it. The relay provides thermal overload protection and must be combined with separately selected short-circuit protective equipment.
Tick the specs you need, then view products that match.
| Device Type | Contactor | |
|---|---|---|
| Coil Type | AC, AC/DC, DC | |
| Manufacturer | Finder | |
| Series | 6K Thermal Overload Protection | |
| Type | 6K.T1 | |
| Model | 6K.T1.0.000.0609 | |
| Manufacturer article number | 6KT100000609 | |
| Product type | Thermal overload relay / motor protection relay | |
| Adjustable current range | 6–9 A | |
| Minimum current setting | 6 A | |
| Maximum current setting | 9 A | |
| Trip class | Class 10A | |
| Rated insulation voltage | 690 V | |
| Maximum rated operational voltage | 690 V | |
| Auxiliary contacts | 1 NO + 1 NC | |
| Auxiliary contact material | Silver nickel (AgNi) | |
| Reset functionality | Manual and automatic | |
| Manual reset | Integrated reset button | |
| Stop function | Integrated stop button | |
| Operating principle | Thermal overload protection | |
| Mounting type | Direct mounting to compatible contactor | |
| Compatible contactor types | Finder 6K.13 and 6K.14 | |
| Main circuit connection | Screw terminals | |
| Terminal design | Cage-clamp terminals | |
| Protection rating | IP20 | |
| Dimensions (W × H × D) | 45 × 74 × 104.5 mm | |
| Weight | approx. 0.14 kg | |
| Applicable standard | IEC EN 60947-4-1 | |
| EAN | 8012823456829 |
The Finder 6K.T1.0.000.0609 is a thermal overload relay designed to protect industrial electric motors against sustained overcurrent and overheating. It is used with compatible Finder contactors in motor starter and industrial automation applications.
The relay has an adjustable current setting range of 6–9 A. The setting should be selected according to the connected motor's rated full-load current and the requirements of the motor protection system.
The Finder 6K.T1.0.000.0609 is designed for use with Finder 6K.13 and 6K.14 industrial contactors. Its direct-mounting arrangement allows the relay to be integrated into compatible contactor-based motor starter assemblies.
This relay features a Class 10A thermal trip characteristic, providing overload protection with a defined time-current response suitable for appropriately selected motor starting and operating conditions.
Yes. The relay supports manual and automatic reset operation and includes an integrated reset button and stop button. Manual reset allows an operator to restore operation after investigating an overload condition, while automatic reset should only be used where unexpected motor restarting cannot create a hazard.
Finder 6K Series thermal overload relays provide dependable adjustable motor protection for industrial electrical systems, combining practical reset functionality, auxiliary signalling contacts and direct compatibility with Finder industrial contactors to support reliable motor starter design and machinery protection.