Finder 6K.T0.0.000.2704 is a Class 10A thermal overload relay with an adjustable 2.7–4 A current setting, 690 V maximum rated operational voltage, one normally open and one normally closed auxiliary contact and direct-mounting compatibility with Finder 6K.04 mini contactors for electric motor overload protection.

SKU: 6K.T0.0.000.2704Alt SKU: 6KT000002704MPN: 6K.T0.0.000.2704
Price
List Price £60.20 ex VAT
Your Price (ex VAT) Save 35%
£39.13 35% OFF
You save £21.07 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £39.13
Trade pricing is personalised to your account

Manufacturer Lead Time

£39.13

Why Choose the Finder 6K.T0.0.000.2704 Thermal Overload Relay?

The Finder 6K.T0.0.000.2704 is an adjustable thermal overload relay designed to protect electric motors against sustained overload conditions. Part of the Finder 6K industrial contactor and motor protection range, this device is specifically designed for direct attachment to compatible Finder 6K.04 mini contactors, providing a compact and practical motor starter protection solution.

With an adjustable current setting of 2.7–4 A, the Finder 6K.T0.0.000.2704 allows the thermal overload protection threshold to be matched to the rated current of a connected motor. Its Class 10A thermal tripping characteristic provides a defined response to overload conditions, helping reduce the risk of excessive motor heating and associated equipment damage.

The relay features one normally open (1 NO) and one normally closed (1 NC) auxiliary contact for overload signalling and control circuit integration. Additional features include a 690 V maximum rated operational voltage, IP20 protection rating, integrated stop button, automatic reset capability and screw-type main circuit connections.

Key Advantages

  • Adjustable 2.7–4 A overload setting for matching protection to motor rated current.
  • Class 10A thermal tripping characteristic for suitable motor protection applications.
  • Direct mounting compatibility with Finder 6K.04 mini contactors for compact motor starter construction.
  • 690 V maximum rated operational voltage for compatible electrical installations.
  • 1 NO + 1 NC auxiliary contacts for overload indication and control circuit switching.
  • Automatic reset capability for applications where automatic resetting is permitted.
  • Integrated stop button for local control functionality.
  • IP20 protection rating for installation within suitable electrical enclosures.
  • Screw-type main circuit terminals for secure electrical connections.
  • Silver-nickel (AgNi) auxiliary contacts for dependable electrical signalling.

Key Features

  • Finder 6K series thermal motor overload protection relay.
  • Designed for compatible Finder 6K.04 mini contactors.
  • Adjustable current setting from 2.7 to 4 A.
  • Class 10A thermal overload tripping characteristic.
  • Maximum rated operational voltage of 690 V.
  • One normally open auxiliary contact.
  • One normally closed auxiliary contact.
  • Silver-nickel auxiliary contact material.
  • Direct contactor mounting arrangement.
  • Screw-type main circuit connections.
  • Integrated stop button.
  • Automatic reset functionality.
  • IP20 degree of protection.
  • Suitable for coordinated motor starter and overload protection assemblies.
  • No separate operating coil or coil supply required.

Reliable Thermal Overload Protection for Industrial Motors

The Finder 6K.T0.0.000.2704 is designed to help protect electric motors from excessive heating caused by prolonged overload current. Thermal overload relays respond to sustained overcurrent conditions according to a defined time-current characteristic, enabling the motor control system to disconnect the motor before excessive thermal stress occurs.

The adjustable 2.7–4 A current range allows the relay to be set according to the connected motor's nameplate current and the manufacturer's selection instructions. This flexibility makes it suitable for appropriately rated small motor applications where accurate overload setting is important.

The Class 10A tripping characteristic defines the relay's overload response under specified test conditions. It is commonly associated with motor starter applications where a relatively fast thermal response is required. The actual trip time depends on the degree of overload and the applicable operating conditions.

The relay's normally closed auxiliary contact can be incorporated into the contactor control circuit so that an overload trip interrupts the contactor coil supply. The normally open auxiliary contact can provide an overload indication to a signalling device or monitoring system.

Designed for direct mounting onto Finder 6K.04 mini contactors, the relay supports compact motor starter assemblies with fewer separate components. Its automatic reset capability must only be used where the electrical control system prevents hazardous unexpected restarting.

Important: A thermal overload relay does not replace short-circuit protection. Suitable fuses or circuit breakers must be provided in accordance with the electrical installation and motor starter coordination requirements.

Typical Applications

  • Motor starter assemblies using Finder 6K.04 mini contactors.
  • Thermal overload protection for motors rated within the relay's adjustable current range.
  • Industrial electrical control panels.
  • Small industrial pump motor starters.
  • Ventilation and fan motor control systems.
  • Conveyor and material-handling equipment.
  • Industrial machinery and manufacturing equipment.
  • OEM motor control and automation assemblies.
  • Motor overload monitoring and fault indication circuits.
  • Maintenance and replacement of compatible Finder 6K motor protection devices.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Contactor
Coil Type AC, AC/DC, DC
Manufacturer Finder
Series 6K
Product type Thermal overload relay
Manufacturer part number 6K.T0.0.000.2704
Alternative manufacturer code 6KT000002704
Compatible contactor series Finder 6K.04
Adjustable current range 2.7–4 A
Minimum current setting 2.7 A
Maximum current setting 4 A
Maximum rated operational voltage (Ue) 690 V
Thermal trip class Class 10A
Normally open auxiliary contacts 1
Normally closed auxiliary contacts 1
Auxiliary contact configuration 1 NO + 1 NC
Auxiliary contact material Silver-nickel (AgNi)
Mounting method Direct attachment to compatible contactor
Main circuit connection Screw terminals
Stop button Yes
Automatic reset capability Yes
Remote electrical reset input No
Push-button reset function No
Protection rating IP20
Operating principle Thermal overload detection
EAN / GTIN-13 8012823456683

Frequently Asked Questions

What is the Finder 6K.T0.0.000.2704 used for?

The Finder 6K.T0.0.000.2704 is a thermal overload relay designed to protect appropriately rated electric motors against sustained overload conditions when used with compatible Finder 6K.04 mini contactors.

What is the adjustable current range of this overload relay?

The relay has an adjustable current setting of 2.7–4 A, allowing its thermal overload protection threshold to be matched to the connected motor's rated current.

Which Finder contactors are compatible with the 6K.T0.0.000.2704?

The Finder 6K.T0.0.000.2704 is designed for direct attachment to Finder 6K.04 mini contactors. Compatibility with other contactor sizes should be checked separately.

What does Class 10A mean on this thermal overload relay?

Class 10A identifies the thermal overload relay's tripping characteristic under defined test conditions. It is intended for compatible motor starting and overload protection applications.

Does the Finder 6K.T0.0.000.2704 have auxiliary contacts?

Yes. The relay includes one normally open and one normally closed auxiliary contact for overload indication, signalling and integration into motor control circuits.

Can this thermal overload relay reset automatically?

Yes. The Finder 6K.T0.0.000.2704 supports automatic reset. This capability should only be used where unexpected motor restarting cannot create a hazard.

Does the Finder 6K.T0.0.000.2704 provide short-circuit protection?

No. The relay provides thermal overload protection and must be used with appropriately selected short-circuit protective devices, such as fuses or circuit breakers.

What is the maximum rated operational voltage of this overload relay?

The Finder 6K.T0.0.000.2704 has a maximum rated operational voltage of 690 V, subject to the specified installation and operating conditions.

Designed for Professional Motor Protection Installations

The Finder 6K.T0.0.000.2704 provides adjustable thermal overload protection for compatible Finder 6K.04 motor starter assemblies. With its 2.7–4 A current setting, Class 10A tripping characteristic, integrated auxiliary contacts and direct-mounting design, it offers a practical motor protection solution for electrical engineers, industrial panel builders, automation specialists and maintenance professionals.