Finder 6K.T0.0.000.0811 - 6K Series Industrial contactors

Finder 6K.T0.0.000.0811 – 6K Series Industrial contactors

Finder 6K.T0.0.000.0811 is a Class 10A thermal motor overload relay with an adjustable 8–11 A current setting range, one normally open and one normally closed auxiliary contact, and direct-mount compatibility with Finder 6K.04 mini contactors.

SKU: 6K.T0.0.000.0811Alt SKU: 6KT000000811MPN: 6K.T0.0.000.0811
Price
List Price £68.45 ex VAT
Your Price (ex VAT) Save 35%
£44.49 35% OFF
You save £23.96 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £44.49
Trade pricing is personalised to your account

Manufacturer Lead Time

£44.49

Why Choose the Finder 6K.T0.0.000.0811 Thermal Overload Relay?

The Finder 6K.T0.0.000.0811 is an adjustable 8–11 A thermal overload relay designed to protect electrical motors against sustained overload conditions when used with compatible Finder Series 6K.04 mini contactors. Part of the Finder Series 6K motor control range, this protection device helps reduce the risk of motor overheating caused by excessive operating current.

Featuring a Class 10A thermal tripping characteristic, the Finder 6K.T0.0.000.0811 provides overload protection for appropriately rated industrial motors. Its adjustable current setting allows the protection threshold to be matched to the connected motor's rated current within the specified 8–11 A range.

The relay incorporates one normally open and one normally closed auxiliary contact for overload signalling and contactor control. With direct mounting compatibility for Finder 6K.04 contactors, a maximum rated operational voltage of 690 V and IP20 protection, it is suitable for integration into appropriately designed industrial motor starter assemblies.

Key Advantages

  • Adjustable 8–11 A current setting range for motor overload protection.
  • Class 10A thermal overload tripping for suitable motor starting and operating conditions.
  • Designed for Finder 6K.04 mini contactors for compatible motor starter assemblies.
  • Direct attachment to compatible contactors for straightforward integration.
  • 1 NO + 1 NC auxiliary contacts for overload indication and control circuit interruption.
  • 690 V maximum rated operational voltage.
  • IP20 degree of protection for installation within suitable electrical enclosures.
  • Screw terminal connections for electrical wiring.
  • Integrated stop button for control and testing functions.
  • Automatic reset capability for suitable control arrangements.
  • Helps protect motors against sustained overload conditions when correctly selected and installed.

Key Features

  • Finder Series 6K thermal motor overload relay.
  • 8–11 A adjustable current setting.
  • Class 10A overload tripping classification.
  • Compatible with Finder 6K.04 mini contactors.
  • Direct-mount installation arrangement.
  • One normally open auxiliary contact for signalling.
  • One normally closed auxiliary contact for control circuit interruption.
  • Maximum rated operational voltage of 690 V.
  • AgNi auxiliary contact material.
  • IP20 protection rating.
  • Screw-type main circuit connections.
  • Integrated stop button.
  • Automatic reset capability.
  • Thermal overload protection for appropriately rated industrial motors.

Reliable Thermal Overload Protection for Industrial Motor Starters

The Finder 6K.T0.0.000.0811 provides thermal overload protection for motors controlled through compatible Finder 6K.04 mini contactors. Its adjustable 8–11 A current range enables the protection setting to be matched to the motor's rated operating current, helping reduce the risk of damage caused by prolonged overload conditions.

When the overload relay trips, its auxiliary contacts change state. The normally closed auxiliary contact can be connected into the contactor control circuit to interrupt the coil supply, while the normally open auxiliary contact can provide an overload indication or fault signal to compatible monitoring equipment.

The relay's Class 10A tripping characteristic should be considered alongside the motor's starting time, full-load current and operating duty. Thermal overload protection does not replace short-circuit protection; suitable fuses or circuit breakers must also be included in the complete motor starter installation. Reset arrangements should be selected to prevent unintended motor restarting.

Typical Applications

  • Industrial motor starter assemblies using Finder 6K.04 mini contactors.
  • Three-phase motor overload protection.
  • Industrial pumps and pumping systems.
  • Conveyor and material handling equipment.
  • Fans and ventilation motor control.
  • Compressors and motor-driven industrial machinery.
  • Automated manufacturing and production equipment.
  • Industrial electrical control panels.
  • Motor overload signalling and fault monitoring circuits.
  • OEM machinery and electrical panel manufacturing.
  • Maintenance and replacement of compatible motor protection devices.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Contactor
Coil Type AC, AC/DC, DC
Manufacturer Finder
Series 6K
Model 6K.T0.0.000.0811
Manufacturer article number 6KT000000811
Product type Thermal motor overload relay
Adjustable current setting range 8–11 A
Tripping class Class 10A
Maximum rated operational voltage 690 V
Compatible contactor family Finder 6K.04
Mounting method Direct attachment to compatible contactor
Normally open auxiliary contacts 1 NO
Normally closed auxiliary contacts 1 NC
Auxiliary contact material AgNi
Main circuit connection Screw terminals
Degree of protection IP20
Stop function Integrated stop button
Automatic reset capability Yes
EAN 8012823456744

Frequently Asked Questions

What is the Finder 6K.T0.0.000.0811 used for?

The Finder 6K.T0.0.000.0811 is a thermal overload relay used to help protect appropriately rated electrical motors against sustained overload conditions. It is designed for direct attachment to compatible Finder 6K.04 mini contactors.

What is the adjustable current range of the Finder 6K.T0.0.000.0811?

The overload relay has an adjustable current setting range of 8–11 A. The setting should be selected according to the connected motor's rated current and the manufacturer's installation guidance.

Which Finder contactors are compatible with this overload relay?

The Finder 6K.T0.0.000.0811 is designed for Finder Series 6K.04 mini contactors and uses a direct-attachment mounting arrangement. Compatibility with other contactor models should not be assumed.

What does Class 10A mean on this thermal overload relay?

Class 10A identifies the thermal overload relay's tripping classification. It is used when selecting overload protection for motors with appropriate starting characteristics and operating requirements.

Does the Finder 6K.T0.0.000.0811 include auxiliary contacts?

Yes. The relay includes one normally open (1 NO) and one normally closed (1 NC) auxiliary contact. These contacts can be used for overload indication and interruption of the associated contactor control circuit when the relay trips.

Trusted by Industrial Automation Professionals Worldwide

Finder Series 6K thermal overload relays provide practical motor protection solutions for machine builders, electrical panel manufacturers, maintenance engineers and industrial automation professionals. Combining an adjustable 8–11 A current range, Class 10A tripping characteristics and compatibility with Finder 6K.04 mini contactors, the Finder 6K.T0.0.000.0811 supports dependable overload protection in professionally designed industrial motor starter systems.