Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 6K.T0.0.000.0609 is a Class 10A thermal motor overload relay with an adjustable 6–9 A current setting range, 1 NO and 1 NC auxiliary contacts, and direct-mount compatibility with Finder 6K.04 mini contactors.
£44.49
The Finder 6K.T0.0.000.0609 is an adjustable thermal overload relay designed to provide motor overload protection when used with compatible Finder Series 6K.04 mini contactors. Featuring a 6–9 A adjustable current setting range, this motor protection device helps safeguard electrical motors against sustained overcurrent conditions that could otherwise cause excessive heating and damage.
Part of the Finder Series 6K industrial motor control range, the 6K.T0.0.000.0609 is designed for direct mounting to compatible 6K.04 contactors. It incorporates Class 10A thermal overload tripping characteristics, together with one normally open and one normally closed auxiliary contact for overload signalling and control circuit interruption.
With a maximum rated operational voltage of 690 V, IP20 protection and screw-type electrical connections, this overload relay is suitable for incorporation into appropriately designed industrial motor starter assemblies. Its adjustable setting allows the protection threshold to be matched to the motor's rated current within the specified range.
The Finder 6K.T0.0.000.0609 provides thermal overload protection for motors controlled through compatible Finder 6K.04 contactors. Its adjustable 6–9 A setting enables the relay to be configured according to the motor's rated current, helping reduce the risk of overheating caused by prolonged overload conditions.
When an overload condition causes the relay to trip, its auxiliary contacts change state. The normally closed auxiliary contact can be incorporated into the contactor control circuit to interrupt the coil supply, while the normally open auxiliary contact can be used to provide an overload indication or signal to compatible monitoring equipment.
The relay's Class 10A tripping characteristic is intended for applications requiring relatively rapid overload protection. Correct selection should take account of the motor's starting characteristics, full-load current and operating duty. A thermal overload relay does not replace short-circuit protection; suitable fuses or circuit breakers must also be provided as part of the complete motor starter installation.
Tick the specs you need, then view products that match.
| Device Type | Contactor | |
|---|---|---|
| Coil Type | AC, AC/DC, DC | |
| Manufacturer | Finder | |
| Series | 6K | |
| Model | 6K.T0.0.000.0609 | |
| Manufacturer article number | 6KT000000609 | |
| Product type | Thermal motor overload relay | |
| Adjustable current setting range | 6–9 A | |
| Tripping class | Class 10A | |
| Maximum rated operational voltage | 690 V | |
| Compatible contactor family | Finder 6K.04 | |
| Mounting method | Direct attachment to compatible contactor | |
| Normally open auxiliary contacts | 1 NO | |
| Normally closed auxiliary contacts | 1 NC | |
| Auxiliary contact material | AgNi | |
| Main circuit connection | Screw terminals | |
| Degree of protection | IP20 | |
| Stop function | Integrated stop button | |
| Automatic reset capability | Yes | |
| EAN | 8012823456720 |
The Finder 6K.T0.0.000.0609 is a thermal overload relay used to help protect appropriately rated electrical motors against sustained overload conditions. It is designed for use with compatible Finder 6K.04 mini contactors.
The Finder 6K.T0.0.000.0609 has an adjustable current setting range of 6–9 A. The setting should be selected according to the connected motor's rated current and the manufacturer's installation guidance.
This overload relay is designed for Finder Series 6K.04 mini contactors and uses a direct-attachment mounting arrangement. It should not be assumed to fit other Finder contactor families without checking compatibility.
Class 10A identifies the relay's thermal overload tripping classification. It is used when selecting protection for motors with suitable starting characteristics and overload protection requirements.
Yes. The relay includes one normally open (1 NO) and one normally closed (1 NC) auxiliary contact. These can be used for overload indication and interruption of the associated contactor control circuit when the relay trips.
Finder Series 6K thermal overload relays provide practical motor protection solutions for machine builders, electrical panel manufacturers, maintenance engineers and automation professionals. Combining an adjustable 6–9 A current range, Class 10A tripping characteristics and compatibility with Finder 6K.04 mini contactors, the Finder 6K.T0.0.000.0609 supports reliable overload protection in professionally designed industrial motor starter systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.