Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 6K.T0.0.000.0406 is an adjustable 4–6 A Class 10A thermal overload relay for Finder 6K.04 mini contactors, featuring one normally open and one normally closed auxiliary contact, direct mounting and IP20 protection for industrial motor starter applications.
£39.13
The Finder 6K.T0.0.000.0406 is an adjustable 4–6 A thermal overload relay designed to protect three-phase electric motors against sustained overload conditions. Part of the Finder Series 6K motor protection range, this device is specifically designed for use with Finder 6K.04 mini contactors, providing a practical motor protection solution for industrial automation, machinery and electrical control panels.
Featuring an adjustable current setting range of 4–6 A and a Class 10A tripping characteristic, the Finder 6K.T0.0.000.0406 helps prevent motor damage caused by excessive current over time. Its thermal overload protection mechanism responds to sustained overcurrent conditions, making it suitable for appropriately rated three-phase motors in pumps, fans, conveyors and industrial processing equipment.
The relay includes one normally open (1 NO) and one normally closed (1 NC) auxiliary contact for fault signalling and control circuit integration. With direct mounting to compatible Finder 6K.04 contactors, screw terminal connections, a stop button and an IP20 protection rating, it offers a convenient solution for building compact motor starter assemblies.
The Finder 6K.T0.0.000.0406 is designed to provide thermal overload protection for motors controlled by compatible Finder 6K.04 mini contactors. During normal operation, motor current passes through the relay's sensing elements. If the motor draws excessive current for a sufficient period, the thermal mechanism trips and changes the state of its auxiliary contacts, allowing the associated control circuit to disconnect the motor through the contactor.
The 4–6 A adjustable current range allows the relay to be set according to the motor's rated current, provided that the required setting falls within this range. Correct adjustment is essential for effective motor protection. The Class 10A tripping characteristic is intended for motor applications with starting and overload characteristics compatible with this trip class. Motor starting time and operating duty must be considered when selecting the relay.
The integrated 1 NO + 1 NC auxiliary contacts support motor control and fault signalling. The normally closed contact can be incorporated into a suitable contactor control circuit so that an overload trip interrupts the contactor coil supply, while the normally open contact can provide a fault indication to a control panel, indicator or PLC input.
The relay supports automatic reset, but automatic restarting must be assessed carefully. Where an unexpected motor restart could create a hazard, the control circuit should prevent automatic re-energisation until the appropriate reset and restart conditions have been satisfied. The relay does not replace short-circuit protection, electrical isolation or other protective devices required for a complete motor starter assembly.
Tick the specs you need, then view products that match.
| Device Type | Contactor | |
|---|---|---|
| Coil Type | AC, AC/DC, DC | |
| Series | 6K | |
| Manufacturer part number | 6K.T0.0.000.0406 | |
| Product type | Thermal motor overload relay | |
| Protection function | Thermal motor overload protection | |
| Adjustable current range | 4–6 A | |
| Trip class | Class 10A | |
| Compatible contactor | Finder Series 6K.04 mini contactors | |
| Mounting type | Direct contactor mounting | |
| Main circuit connection | Screw terminals | |
| Auxiliary contacts | 1 NO + 1 NC | |
| Normally open auxiliary contacts | 1 | |
| Normally closed auxiliary contacts | 1 | |
| Auxiliary contact material | Silver nickel (AgNi) | |
| Maximum rated operational voltage | 690 V | |
| Rated insulation voltage | 690 V | |
| Reset capability | Automatic reset supported | |
| Integrated control | Stop button | |
| Protection rating | IP20 | |
| Applicable motor starter standard | IEC/EN 60947-4-1 | |
| EAN / GTIN | 8012823456706 | |
| Manufacturer | Finder |
The Finder 6K.T0.0.000.0406 is a thermal overload relay used to protect electric motors against sustained overload conditions. It is designed for integration with compatible Finder 6K.04 mini contactors in industrial motor starter assemblies.
The relay has an adjustable current setting range of 4–6 A. The setting should be selected according to the motor's rated current and the applicable motor protection requirements.
The Finder 6K.T0.0.000.0406 is specifically designed for Finder Series 6K.04 mini contactors. It is not the corresponding overload relay model for Finder 6K.13 or 6K.14 contactors, which use the 6K.T1 range.
Class 10A describes the relay's overload tripping performance under defined test conditions. It is commonly used for motor applications requiring relatively rapid overload disconnection. The selected trip class must be compatible with the motor's starting characteristics and operating duty.
Yes. The relay includes one normally open (1 NO) and one normally closed (1 NC) auxiliary contact. These contacts can be used for motor starter control, overload trip indication and signalling to industrial automation equipment.
Yes. The Finder 6K.T0.0.000.0406 supports automatic reset. The control system must be designed to prevent hazardous unexpected restarting, and automatic reset should only be used where suitable for the machinery and applicable safety requirements.
The relay is designed for direct mounting to compatible Finder 6K.04 mini contactors. Its main current circuit uses screw terminal connections. Installation and wiring should follow the manufacturer's instructions and applicable electrical standards.
The Finder 6K.T0.0.000.0406 has a maximum rated operational voltage of 690 V. The complete motor starter assembly must also comply with the ratings of the associated contactor and protective equipment.
Both models provide an adjustable 4–6 A thermal overload protection range. The 6K.T0.0.000.0406 is designed for Finder 6K.04 mini contactors, whereas the 6K.T1.0.000.0406 is intended for Finder 6K.13 and 6K.14 contactors. They should not be treated as interchangeable without confirming mechanical and electrical compatibility.
No. The Finder 6K.T0.0.000.0406 is designed for thermal overload protection and does not independently provide short-circuit protection. An appropriately rated fuse or circuit breaker must be provided as part of the complete motor protection system.
Finder Series 6K thermal overload relays provide dependable motor protection for industrial automation and electrical control applications. The Finder 6K.T0.0.000.0406 combines an adjustable 4–6 A current range, Class 10A tripping characteristic, 1 NO + 1 NC auxiliary contacts and direct compatibility with Finder 6K.04 mini contactors, offering a practical solution for compact industrial motor starter assemblies.