Finder 6K.14.9.048.4718 - 6K Series Industrial contactors

Finder 6K.14.9.048.4718 – 6K Series Industrial contactors

Finder 6K.14.9.048.4718 is an industrial electromagnetic contactor with three normally closed main contacts, one normally open and one normally closed auxiliary contact, a 48 V DC control coil and an 18 A AC-3 operational rating at 400 V AC for industrial electrical switching and automation applications.

SKU: 6K.14.9.048.4718Alt SKU: 6K1490484718MPN: 6K.14.9.048.4718
Price
List Price £97.20 ex VAT
Your Price (ex VAT) Save 35%
£63.18 35% OFF
You save £34.02 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £63.18
Trade pricing is personalised to your account

Manufacturer Lead Time

£63.18

Why Choose the Finder 6K.14.9.048.4718 Industrial Contactor?

The Finder 6K.14.9.048.4718 is a reliable industrial electromagnetic contactor designed for controlled electrical switching in motor control, industrial automation and electrical distribution applications. As part of the Finder 6K industrial contactor series, it provides dependable switching functionality for machinery control panels, motor control centres and industrial electrical installations.

Featuring three normally closed (3 NC) main contacts and integrated one normally open (1 NO) and one normally closed (1 NC) auxiliary contact, this contactor combines main power circuit switching with additional control and signalling capabilities. Its 48 V DC electromagnetic operating coil enables remote operation through compatible DC control circuits, automation controllers and industrial control equipment.

With a rated operational current of 18 A in AC-3 applications at 400 V AC and a rated operational power of 7.5 kW at 400 V AC, the Finder 6K.14.9.048.4718 is suitable for appropriately designed industrial switching installations. Its modular construction and busbar-compatible main terminal connections support integration into industrial electrical panels and power distribution assemblies.

Key Advantages

  • Reliable industrial electromagnetic contactor for electrical power switching and automation.
  • 18 A AC-3 operational current at 400 V AC.
  • 7.5 kW rated operational power at 400 V AC under specified AC-3 conditions.
  • 48 V DC electromagnetic operating coil for compatible industrial control circuits.
  • Three normally closed main contacts for applications requiring normally closed switching.
  • Integrated 1 NO + 1 NC auxiliary contacts for signalling, monitoring and electrical interlocking.
  • 18 A AC-4 operational current for specified demanding motor switching duties.
  • Modular construction for integration into industrial electrical assemblies.
  • Busbar main terminal connection for suitable power distribution arrangements.
  • Suitable for industrial automation, machinery control and electrical switching systems.

Key Features

  • Finder 6K industrial contactor series.
  • Three normally closed main power contacts.
  • 1 NO + 1 NC auxiliary contact arrangement.
  • 48 V DC rated control voltage.
  • 18 A rated operational current (AC-3) at 400 V AC.
  • 18 A rated operational current (AC-4) at 400 V AC.
  • 7.5 kW rated operational power (AC-3) at 400 V AC.
  • 7.5 kW rated operational power (AC-4) at 400 V AC.
  • Electromagnetic operating mechanism for remotely controlled switching.
  • Normally closed main contacts for specialised electrical switching arrangements.
  • Integrated auxiliary contacts for control feedback, signalling and interlocking.
  • Busbar connection arrangement for main power terminals.
  • Modular construction for industrial electrical panel integration.
  • Suitable for use with appropriately rated industrial control and protection equipment.

Reliable Electrical Switching for Industrial Control Systems

Industrial electromagnetic contactors such as the Finder 6K.14.9.048.4718 provide electrically controlled switching of connected power circuits. When the operating coil is energised, the electromagnetic mechanism changes the state of the main contacts. With its normally closed main contact arrangement, the contacts are closed when the coil is de-energised and open when the contactor is actuated.

The Finder 6K series is designed for electrical installations requiring dependable switching and integration with industrial control systems. The three normally closed main contacts provide a switching arrangement suitable for specific control applications, while the integrated auxiliary contacts enable additional signalling, monitoring and electrical interlocking functions.

The AC-3 utilisation category relates to normal starting and stopping of squirrel-cage motors, while AC-4 covers more demanding switching duties such as plugging and inching. Correct selection should account for the normally closed contact arrangement, connected load characteristics, switching frequency, control voltage and applicable electrical protection requirements.

Typical Applications

  • Industrial electrical control panels and distribution assemblies.
  • Automation circuits requiring normally closed power contacts.
  • Industrial machinery and manufacturing equipment.
  • Electrical load switching and control installations.
  • Motor control circuits requiring compatible normally closed switching arrangements.
  • Industrial pump and process control systems.
  • Electrical interlocking and auxiliary signalling circuits.
  • PLC-controlled machinery and automation systems.
  • Control installations using 48 V DC operating circuits.
  • OEM machinery and industrial electrical equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Terminal Type Bar / bolt
Device Type Contactor
Coil Type DC
Coil Voltage Range 42–48 V
Manufacturer Finder
Series 6K Industrial Contactors
Model 6K.14.9.048.4718
Product type Industrial electromagnetic contactor
Number of main contacts 3
Main contact configuration 3 NC (normally closed)
Auxiliary contact configuration 1 NO + 1 NC
Rated control voltage 48 V DC
Control voltage type DC
Rated operational current (AC-3, 400 V AC) 18 A
Rated operational current (AC-4, 400 V AC) 18 A
Rated operational power (AC-3, 400 V AC) 7.5 kW
Rated operational power (AC-4, 400 V AC) 7.5 kW
Main terminal connection Busbar connection
Construction Modular
Operating principle Electromagnetic switching
Utilisation categories AC-3 / AC-4
Typical installation Industrial electrical control panels and distribution assemblies
EAN 8012823457437

Frequently Asked Questions

What is the Finder 6K.14.9.048.4718 used for?

The Finder 6K.14.9.048.4718 is an industrial electromagnetic contactor designed for controlled switching of electrical loads in industrial automation, machinery control and electrical distribution applications.

What control voltage does the Finder 6K.14.9.048.4718 require?

This contactor uses a 48 V DC electromagnetic operating coil, allowing it to be actuated through a compatible DC control circuit.

What is the rated operational current of this contactor?

The Finder 6K.14.9.048.4718 has a rated operational current of 18 A in AC-3 applications at 400 V AC and a rated 18 A AC-4 operational current at the same voltage.

How many main and auxiliary contacts does this contactor have?

The contactor features three normally closed (3 NC) main contacts together with one normally open (1 NO) and one normally closed (1 NC) auxiliary contact.

What operational power is associated with this contactor?

The Finder 6K.14.9.048.4718 has a rated operational power of 7.5 kW at 400 V AC for the specified AC-3 and AC-4 utilisation categories. Suitability for a particular application depends on the switching arrangement and operating conditions.

How do the normally closed main contacts operate?

The normally closed main contacts are closed when the operating coil is de-energised. When the coil is energised, the electromagnetic mechanism opens these contacts, interrupting the connected circuits.

What type of main terminal connection does this contactor use?

The Finder 6K.14.9.048.4718 features a busbar connection arrangement for its main power terminals, supporting integration into suitable industrial electrical assemblies.

Where is the Finder 6K.14.9.048.4718 typically installed?

The contactor is typically installed within industrial electrical control panels, automation cabinets and distribution assemblies as part of a properly designed electrical switching system.

Trusted by Industrial Automation Professionals Worldwide

Finder 6K industrial contactors provide dependable electromagnetic switching solutions for machinery control, electrical distribution and industrial automation applications. With normally closed main contacts, integrated auxiliary signalling and 48 V DC control capability, the Finder 6K.14.9.048.4718 offers a practical solution for electrical engineers, panel builders, automation specialists and industrial maintenance professionals.