Finder 6K.14.9.012.4818 is an 18 A AC-3 industrial contactor featuring a 12 V DC coil, three normally open main power contacts, one normally open auxiliary contact, a 32 A AC-1 rating at 690 V AC and a 7.5 kW motor power rating at 400 V AC for industrial motor control and electromagnetic power switching.
£63.18
The Finder 6K.14.9.012.4818 is a compact industrial electromagnetic contactor designed for dependable three-phase motor control, electrical load switching and industrial automation. Featuring a 12 V DC operating coil, three normally open main power contacts and one normally open auxiliary contact (3 NO + 1 NO), this contactor combines industrial power switching with an integrated control and signalling function.
Part of the Finder Series 6K.14 industrial contactor range, the 6K.14.9.012.4818 provides an 18 A AC-3 operational current rating at 400 V AC, a 7.5 kW AC-3 motor power rating at 400 V AC and a 32 A AC-1 operational current rating at 690 V AC. Its low-voltage DC coil makes it suitable for machinery and control panels equipped with a compatible 12 V DC control supply.
The contactor incorporates silver tin oxide (AgSnO₂) contacts, box-clamp screw terminals, 35 mm DIN rail mounting and an IP20 protection rating. With its integrated normally open auxiliary contact and compatibility with selected Finder auxiliary modules and thermal overload relays, it provides a practical solution for electrical panel builders, OEM machinery manufacturers and industrial maintenance engineers.
The Finder 6K.14.9.012.4818 operates through an electromagnetic mechanism controlled by its 12 V DC coil. When the appropriate control voltage is applied, the three normally open main power contacts close to energise the connected electrical load. At the same time, the normally open auxiliary contact closes, providing a separate switching function for a suitably rated control or signalling circuit. Removing the coil supply allows the contacts to return to their normally open positions.
The integrated normally open auxiliary contact is particularly useful in industrial automation systems requiring contactor status indication, control signalling or appropriately designed holding circuits. Its 2 A AC-15 rating at 400 V AC is separate from the main contacts' motor switching rating. The auxiliary contact must therefore be used within its own electrical limits and should not be treated as an additional motor power contact.
The contactor's 18 A AC-3 rating and 7.5 kW motor power rating at 400 V AC make it suitable for specified squirrel-cage motor switching duties. Its AgSnO₂ contact material, low-power DC coil and DIN rail construction support integration into industrial electrical control panels. For a complete motor starter, suitable overload protection, short-circuit protection and conductor sizing must be selected, with protective coordination verified against the manufacturer's installation requirements.
Tick the specs you need, then view products that match.
| Terminal Type | Screw | |
|---|---|---|
| Device Type | Contactor | |
| Coil Type | DC | |
| Coil Voltage Range | 12 V | |
| Manufacturer | Finder | |
| Manufacturer Part Number | 6K.14.9.012.4818 | |
| Product Series | Finder Series 6K | |
| Contactor Type | 6K.14 | |
| Product Type | Industrial electromagnetic contactor | |
| Contact Configuration | 3 NO + 1 NO | |
| Main Contact Arrangement | 3 normally open | |
| Auxiliary Contact Arrangement | 1 normally open | |
| Number of Main Power Poles | 3 | |
| Number of Integrated Auxiliary Contacts | 1 | |
| Nominal Coil Voltage | 12 V DC | |
| Coil Supply Type | Direct current (DC) | |
| DC Coil Operating Range | 0.8–1.1 × nominal voltage | |
| Rated DC Coil Power | 2 W | |
| Rated Operational Current, AC-3 | 18 A at 400 V AC | |
| Rated Motor Power, AC-3 at 400 V AC | 7.5 kW | |
| Rated Motor Power, AC-3 at 690 V AC | 10 kW | |
| Rated Operational Current, AC-1 | 32 A at 690 V AC | |
| Auxiliary Contact Rating, AC-15 | 2 A at 400 V AC | |
| DC-1 Breaking Capacity at 24 V DC | 32 A | |
| DC-1 Breaking Capacity at 110 V DC | 6 A | |
| DC-1 Breaking Capacity at 220 V DC | 0.8 A | |
| DC-3 Breaking Capacity at 24 V DC | 32 A | |
| DC-3 Breaking Capacity at 110 V DC | 1.2 A | |
| DC-3 Breaking Capacity at 220 V DC | 0.2 A | |
| Contact Material | Silver tin oxide (AgSnO₂) | |
| Mechanical Life | 10 million operating cycles | |
| Typical Operate Time | 10 ms | |
| Typical Release Time | 8 ms | |
| Mounting Method | DIN rail or suitable panel mounting | |
| Compatible DIN Rail | 35 mm, EN 60715 | |
| Terminal Type | Box-clamp screw terminals | |
| Protection Rating | IP20 | |
| Operating Temperature Range | −40 to +70 °C | |
| Extended Temperature Operation | Up to +90 °C with a restricted coil operating range of 0.9–1.0 × nominal voltage | |
| Compatible Auxiliary Contact Accessories | Finder 06K.11 and 06K.12 modules | |
| Compatible Thermal Overload Relay Series | Finder 6K.T1 | |
| Applicable Standard | IEC/EN 60947-4-1 | |
| Product Category | Industrial motor control and electromagnetic power switching |
The Finder 6K.14.9.012.4818 is an industrial contactor designed for three-phase motor control, electrical load switching and industrial automation. It features three normally open main power contacts and one normally open auxiliary contact.
The contactor features a 12 V DC nominal operating coil. Its DC coil operating range is 0.8–1.1 times nominal voltage under the manufacturer's specified standard operating conditions.
The 3 NO + 1 NO configuration consists of three normally open main power contacts and one normally open auxiliary contact. The auxiliary contact provides a separate control and signalling function and has a different electrical rating from the main contacts.
The Finder 6K.14.9.012.4818 has an 18 A AC-3 operational current rating at 400 V AC. AC-3 applies to specified squirrel-cage motor starting and stopping duties.
The contactor has a 7.5 kW AC-3 motor power rating at 400 V AC and a 10 kW AC-3 rating at 690 V AC. Actual motor suitability must also be checked against its rated current, starting characteristics and protection requirements.
The Finder 6K.14.9.012.4818 has a 32 A AC-1 operational current rating at 690 V AC for non-inductive or slightly inductive loads. This rating must not be substituted for the contactor's AC-3 motor switching rating.
The normally open auxiliary contact can be used for suitably rated contactor status indication, control signalling and electrical interlocking. It has a 2 A AC-15 rating at 400 V AC and is not intended to function as an additional main motor power contact.
Both contactors belong to the Finder Series 6K.14 range and use 12 V DC coils with an 18 A AC-3 rating. The 4818 version has three normally open main contacts and one normally open auxiliary contact, while the 4718 version has three normally open main contacts and one normally closed mirror auxiliary contact.
The 4810 version has a 10 A AC-3 rating and a 4 kW motor power rating, while the 4818 version has an 18 A AC-3 rating and a 7.5 kW motor power rating, both at 400 V AC. Both versions use a 3 NO + 1 NO contact arrangement.
Yes. The Finder Series 6K.14 supports compatible auxiliary contact accessories, including Finder 06K.11 and 06K.12 modules. These provide additional control and signalling functions when installed according to the manufacturer's instructions.
The Finder Series 6K.14 supports suitable Finder 6K.T1 thermal overload protection relays. The relay adjustment range must be selected according to the motor's rated current and the installation's protection requirements.
The Finder Series 6K.14 is specified for an ambient operating temperature range of −40 to +70 °C. Operation up to +90 °C is possible under the manufacturer's specified conditions with a restricted coil operating range of 0.9–1.0 times nominal voltage.
Finder Series 6K industrial contactors provide compact electromagnetic switching solutions for industrial motors, machinery and electrical control systems. Their defined AC-1 and AC-3 ratings, AgSnO₂ contact construction, low-power DC coil options and compatibility with auxiliary contact modules and thermal overload protection equipment make them a practical choice for engineers, panel builders and OEM manufacturers developing dependable industrial motor control installations.