Finder 6K.04.9.048.4709 - 6K Series Industrial contactors

Finder 6K.04.9.048.4709 – 6K Series Industrial contactors

Finder 6K.04.9.048.4709 is a Series 6K mini industrial contactor featuring a 48 V DC operating coil, three normally open main contacts, one normally closed auxiliary mirror contact, a 9 A AC-3 operational current rating and a 4 kW motor rating at 400 V AC.

SKU: 6K.04.9.048.4709Alt SKU: 6K0490484709MPN: 6K.04.9.048.4709
Price
List Price £35.42 ex VAT
Your Price (ex VAT) Save 35%
£23.02 35% OFF
You save £12.40 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £23.02
Trade pricing is personalised to your account

Manufacturer Lead Time

£23.02

Why Choose the Finder 6K.04.9.048.4709 Industrial Contactor?

The Finder 6K.04.9.048.4709 is a compact mini industrial contactor from the Finder Series 6K, designed for dependable electrical switching in industrial automation, motor control and machinery applications. Featuring a 48 V DC nominal operating coil, it provides electromagnetic switching for compatible DC control systems.

This contactor features three normally open main contacts and one normally closed auxiliary mirror contact (3 NO + 1 NC). Its main contacts are rated at 9 A AC-3 at 400 V AC, with a corresponding 4 kW three-phase motor rating. The normally closed auxiliary contact provides a monitoring function and is rated at 2 A AC-15 at 400 V AC.

The Finder 6K.04.9.048.4709 combines silver tin oxide (AgSnO2) contacts, screw-terminal connections and 35 mm DIN rail mounting in a compact design. Its mirror-contact arrangement makes it particularly useful for control systems requiring feedback about the state of the main power contacts.

Key Advantages

  • 48 V DC operating coil for compatible industrial DC control circuits.
  • Three normally open main contacts for three-phase electrical load switching.
  • One normally closed auxiliary mirror contact for contact-state monitoring.
  • 9 A AC-3 rated operational current at 400 V AC.
  • 4 kW motor switching capability at 400 V AC under AC-3 conditions.
  • 20 A AC-1 current rating for suitable resistive loads.
  • Silver tin oxide contact material for robust electrical switching performance.
  • 35 mm DIN rail mounting for convenient control panel installation.
  • Screw-terminal connections for secure electrical wiring.
  • Compact mini contactor construction helps optimise enclosure space.
  • Mirror contact configuration in accordance with EN 60947-4-1.

Key Features

  • Finder Series 6K mini industrial contactor.
  • 48 V DC nominal control voltage.
  • 3 NO + 1 NC contact configuration.
  • Three normally open main power contacts.
  • One normally closed auxiliary mirror contact.
  • 9 A AC-3 operational current at 400 V AC.
  • 4 kW AC-3 motor rating at 400 V AC.
  • 20 A AC-1 operational current for suitable resistive loads.
  • 2 A AC-15 auxiliary contact rating at 400 V AC.
  • Silver tin oxide (AgSnO2) contact material.
  • Electromagnetic, non-latching operating mechanism.
  • DIN rail mounting in accordance with EN 60715.
  • Screw-terminal connections with box-clamp construction.
  • Compatible with selected Finder Series 6K auxiliary contact accessories.

Reliable 48 V DC Motor Control with Auxiliary Mirror Contact Monitoring

The Finder 6K.04.9.048.4709 operates through an electromagnetic coil controlled by a 48 V DC supply. When the coil is energised, the three normally open main contacts close to supply the connected electrical load, while the normally closed auxiliary mirror contact opens. When the coil is de-energised, the main contacts return to their normally open positions and the auxiliary contact returns to its normally closed state, provided the mechanism is operating correctly.

The 3 NO + 1 NC configuration is particularly useful in three-phase motor control circuits requiring auxiliary contact-state feedback. The mirror contact is mechanically arranged so that it cannot be closed simultaneously with a normally open main contact under the conditions defined by EN 60947-4-1. Its 9 A AC-3 rating, compact DIN rail-mounted design and AgSnO2 contact system support integration into industrial control panels. Suitable overload protection, short-circuit coordination and control-system design remain essential.

Typical Applications

  • Three-phase motor starting and stopping circuits.
  • Industrial automation and machinery control systems.
  • Electrical control panels using 48 V DC control supplies.
  • Motor control panels requiring auxiliary contact-state feedback.
  • Industrial pump control equipment.
  • Conveyor and material-handling machinery.
  • Industrial ventilation and fan control systems.
  • Power generation and back-up generator control panels.
  • Electrical distribution and control assemblies.
  • OEM machinery requiring compact industrial contactors.
  • Maintenance and replacement of compatible Finder Series 6K contactors.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Contactor
Coil Type DC
Coil Voltage Range 42–48 V
Manufacturer Finder
Manufacturer part number 6K.04.9.048.4709
Product series Series 6K
Product type Mini industrial contactor
Product category Industrial Contactors
Nominal control voltage 48 V DC
Control supply type Direct current
Number of contact poles 4, including auxiliary contact
Main contact configuration 3 normally open (3 NO)
Auxiliary contact configuration 1 normally closed (1 NC)
Auxiliary contact type Mirror contact
Rated operational current (AC-3, 400 V AC) 9 A
Rated motor power (AC-3, 400 V AC) 4 kW
Rated operational current (AC-1) 20 A
Auxiliary contact rating (AC-15, 400 V AC) 2 A
Contact material Silver tin oxide (AgSnO2)
Mounting arrangement DIN rail mounting
Compatible mounting rail 35 mm DIN rail, EN 60715
Electrical connection Screw terminals with box clamps
Minimum conductor cross-section 0.5 mm²
Maximum conductor cross-section 2.5 mm²
Terminal tightening torque 0.8 Nm
Conductor stripping length 8 mm
Rated conditional short-circuit current 3 kA with specified protective coordination
Specified back-up fuse 40 A gL/gG type
Applicable contactor standard IEC/EN 60947-4-1
Mirror contact standard EN 60947-4-1
EAN 8012823457932

Frequently Asked Questions

What is the Finder 6K.04.9.048.4709 used for?

The Finder 6K.04.9.048.4709 is a mini industrial contactor designed for electrical load switching, particularly three-phase motor control, in industrial automation and machinery applications. Its auxiliary mirror contact also supports contact-state monitoring.

What coil voltage does the Finder 6K.04.9.048.4709 require?

The contactor uses a 48 V DC nominal operating coil. The control supply must remain within the manufacturer's specified operating voltage limits.

What contact configuration does the Finder 6K.04.9.048.4709 have?

The contactor has three normally open main contacts and one normally closed auxiliary mirror contact (3 NO + 1 NC).

What is the AC-3 current rating of the Finder 6K.04.9.048.4709?

The contactor has a 9 A rated operational current at 400 V AC under AC-3 conditions. This rating applies to the specified motor-switching utilisation category.

What motor power can the Finder 6K.04.9.048.4709 control?

The contactor has a 4 kW motor rating at 400 V AC under AC-3 conditions. Motor suitability must be assessed against the actual load current, starting characteristics and operating duty.

What is the purpose of the normally closed mirror contact?

The normally closed auxiliary mirror contact provides contact-state feedback and is designed according to EN 60947-4-1. It is mechanically arranged so that it cannot be closed simultaneously with a normally open main contact under the standard's defined conditions.

What is the auxiliary contact rating of the Finder 6K.04.9.048.4709?

The normally closed auxiliary contact is rated at 2 A under AC-15 conditions at 400 V AC. It is intended for compatible auxiliary control duties rather than the main motor load.

How is the Finder 6K.04.9.048.4709 mounted?

The contactor is designed for mounting on a 35 mm DIN rail in accordance with EN 60715 and uses screw-terminal connections with box clamps.

What conductor sizes are supported by the Finder 6K.04.9.048.4709?

The Finder Series 6K.04 terminal specification supports conductors from 0.5 to 2.5 mm². The specified tightening torque is 0.8 Nm, with an 8 mm conductor stripping length.

Can the Finder 6K.04.9.048.4709 operate from a 48 V AC supply?

No. The 6K.04.9.048.4709 is a 48 V DC coil variant. A 48 V AC supply should not be substituted unless expressly authorised by Finder.

What is the difference between the Finder 6K.04.9.048.4709 and 6K.04.9.048.4312?

Both models use 48 V DC coils, but their contact arrangements and current ratings differ. The 6K.04.9.048.4709 has three normally open main contacts, one normally closed auxiliary mirror contact and a 9 A AC-3 rating. The 6K.04.9.048.4312 has four normally open contacts and a 12 A AC-3 rating. They should not be treated as direct replacements without checking the electrical requirements.

Trusted by Industrial Automation Engineers and Motor Control Panel Builders

Finder Series 6K industrial contactors provide compact electrical switching solutions for industrial automation engineers, machinery manufacturers and electrical panel builders. The Finder 6K.04.9.048.4709 combines a 48 V DC operating coil, three normally open main contacts, one normally closed auxiliary mirror contact and a 9 A AC-3 operational current rating for integration into compatible industrial motor control systems.