Finder 6K.04.8.024.4709 - 6K Series Industrial contactors

Finder 6K.04.8.024.4709 – 6K Series Industrial contactors

Finder 6K.04.8.024.4709 is a compact 9 A AC-3 mini industrial contactor featuring a 24 V AC coil, three normally open main contacts, one normally closed mirror auxiliary contact, a 4 kW motor rating and 35 mm DIN rail mounting for industrial motor control and electrical switching.

SKU: 6K.04.8.024.4709Alt SKU: 6K0480244709MPN: 6K.04.8.024.4709
Price
List Price £29.05 ex VAT
Your Price (ex VAT) Save 35%
£18.88 35% OFF
You save £10.17 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £18.88
Trade pricing is personalised to your account

Manufacturer Lead Time

£18.88

Why Choose the Finder 6K.04.8.024.4709 Mini Industrial Contactor?

The Finder 6K.04.8.024.4709 is a compact, high-performance 9 A industrial motor contactor from the Finder Series 6K range, designed for dependable motor switching, machinery control and industrial electrical automation. Featuring a 24 V AC operating coil, three normally open main contacts and one normally closed auxiliary contact (3 NO + 1 NC), it combines three-phase power switching with integrated contact-state monitoring.

Designed for 35 mm DIN rail mounting, this mini industrial contactor provides a 9 A AC-3 operational current rating at 400 V AC, a 4 kW motor power rating and a 20 A AC-1 resistive current rating. Its normally closed auxiliary contact is configured as a mirror contact in accordance with IEC/EN 60947-4-1, making it particularly useful for electrical interlocking and contactor status feedback in industrial control circuits.

The Finder 6K.04.8.024.4709 uses silver tin oxide (AgSnO₂) contacts and a compact 45 mm-wide housing with screw terminal connections. Its combination of reliable electromagnetic operation, integrated auxiliary contact functionality and clearly defined AC-1 and AC-3 switching ratings makes it suitable for control panel builders, OEM machine manufacturers and industrial maintenance engineers.

Key Advantages

  • 9 A AC-3 motor switching capability: Designed for industrial motor starting and stopping applications.
  • 24 V AC operating coil: Integrates with compatible low-voltage AC control circuits.
  • Three normally open main contacts: Provide simultaneous three-phase electrical load switching.
  • Integrated normally closed auxiliary contact: Supports contactor status monitoring and electrical interlocking.
  • Mirror contact configuration: The NC auxiliary contact provides a defined relationship to the main power contacts in accordance with IEC/EN 60947-4-1.
  • 4 kW AC-3 motor power rating: Suitable for appropriately rated three-phase motors.
  • 20 A AC-1 resistive load rating: Supports non-inductive and slightly inductive switching applications.
  • Compact 45 mm width: Helps conserve space in industrial electrical control panels.
  • 35 mm DIN rail installation: Enables straightforward mounting and maintenance.
  • AgSnO₂ contact construction: Provides resistance to electrical wear and contact welding under specified operating conditions.

Key Features

  • Finder Series 6K.04 mini industrial contactor.
  • 24 V AC nominal coil voltage.
  • Three normally open main power contacts (3 NO).
  • One normally closed auxiliary contact (1 NC).
  • Four-pole contact arrangement comprising three main contacts and one auxiliary contact.
  • 9 A AC-3 operational current at 400 V AC.
  • 4 kW AC-3 motor power rating.
  • 20 A AC-1 current rating.
  • 2 A AC-15 auxiliary contact rating at 400 V AC.
  • Mirror contact arrangement compliant with IEC/EN 60947-4-1.
  • Silver tin oxide (AgSnO₂) contact material.
  • 35 mm DIN rail mounting in accordance with EN 60715.
  • IP20 protection rating.
  • Screw terminal electrical connections.
  • 45 mm compact housing width.
  • Operating temperature range of −40 to +70 °C.

Reliable Three-Phase Motor Switching with Integrated Mirror Contact Feedback

The Finder 6K.04.8.024.4709 uses an electromagnetic operating mechanism controlled by its 24 V AC coil. When the coil is energised, the three normally open main contacts close to supply the connected electrical load, while the normally closed auxiliary contact opens. When the coil supply is removed, the main contacts return to their open positions and the auxiliary contact returns to its normally closed state.

A key advantage of the 4709 contact configuration is its integrated normally closed mirror auxiliary contact. Designed in accordance with IEC/EN 60947-4-1, a mirror contact is mechanically associated with the main contacts so that it cannot be closed at the same time as a normally open main contact remains closed. This characteristic supports contactor monitoring and diagnostic functions, although any safety-related application must be assessed as part of the complete control system.

The contactor provides a 9 A AC-3 rating for specified motor switching duties and a separate 20 A AC-1 rating for non-inductive or slightly inductive loads. Its AgSnO₂ contact material, compact housing and DIN rail mounting support reliable installation in industrial electrical panels. Appropriate motor overload protection, short-circuit protective devices and correctly rated conductors must be selected for the complete installation.

Typical Applications

  • Three-phase motor starting and stopping circuits.
  • Industrial pumps and water treatment equipment.
  • Industrial conveyor and material handling systems.
  • Manufacturing machinery and automated production lines.
  • Electrical control panels requiring contactor status feedback.
  • Industrial motor interlocking and monitoring circuits.
  • Heating, ventilation and air conditioning (HVAC) equipment.
  • Industrial fans, compressors and ventilation systems.
  • OEM machinery using 24 V AC control circuits.
  • Power distribution and industrial electrical switching assemblies.

Technical Specifications

Tick the specs you need, then view products that match.

Terminal Type Screw
Device Type Contactor
Coil Type AC
Coil Voltage Range 24 V
Manufacturer Finder
Manufacturer Part Number 6K.04.8.024.4709
Product Series Finder 6K
Contactor Type 6K.04
Product Type Mini industrial contactor
Contact Configuration 3 NO + 1 NC
Number of Main Contacts 3 normally open
Number of Auxiliary Contacts 1 normally closed
Auxiliary Contact Type Mirror contact
Nominal Coil Voltage 24 V AC
Coil Supply Type Alternating current (AC)
Rated Operational Current, AC-3 9 A at 400 V AC
Rated Motor Power, AC-3 4 kW at 400/440 V AC
Rated Motor Power, AC-3 at 690 V AC 4 kW
Rated Operational Current, AC-1 20 A at 690 V AC
Auxiliary Contact Rating, AC-15 2 A at 400 V AC
Contact Material Silver tin oxide (AgSnO₂)
Mounting Method DIN rail
Compatible DIN Rail 35 mm, EN 60715
Terminal Type Screw terminals with box-clamp connections
Conductor Cross-Section 0.5–2.5 mm²
Protection Rating IP20
Short-Circuit Rating 3 kA under specified protective conditions
Operating Temperature −40 to +70 °C
Product Width 45 mm
Product Height 57.5 mm
Product Depth 45 mm
Overall Dimensions 45 × 57.5 × 45 mm
Approximate Gross Weight 155 g
EAN 8012823449784
Applicable Standard IEC/EN 60947-4-1
Mirror Contact Standard EN 60947-4-1
Environmental Compliance RoHS

Frequently Asked Questions

What is the Finder 6K.04.8.024.4709 used for?

The Finder 6K.04.8.024.4709 is a mini industrial contactor used for three-phase motor switching, industrial machinery control and electrical load management. It features three normally open main contacts and one normally closed auxiliary mirror contact.

What is the coil voltage of the Finder 6K.04.8.024.4709?

The contactor uses a 24 V AC nominal operating coil. It requires an appropriately rated alternating-current control supply and should not be connected directly to a 24 V DC supply.

What does the 3 NO + 1 NC contact configuration mean?

The contactor contains three normally open main power contacts and one normally closed auxiliary contact. The three main contacts close when the coil is energised, while the auxiliary contact opens. This arrangement provides three-phase power switching and a separate contact for control or monitoring functions.

What is the motor switching current rating?

The Finder 6K.04.8.024.4709 has a 9 A AC-3 operational current rating at 400 V AC. The AC-3 rating applies to specified squirrel-cage motor switching duties.

What motor power can the Finder 6K.04.8.024.4709 control?

The contactor is rated for 4 kW AC-3 motor switching at the manufacturer's specified operating voltage. Motor selection must also consider the motor's rated current, starting characteristics, switching duty and required overload protection.

What is a mirror contact on an industrial contactor?

A mirror contact is a normally closed auxiliary contact mechanically linked to the main contacts so that it cannot remain closed when a normally open main contact is closed. This configuration, defined by IEC/EN 60947-4-1, supports contactor status monitoring and diagnostic circuits.

What is the rating of the normally closed auxiliary contact?

The normally closed auxiliary contact has a specified 2 A AC-15 rating at 400 V AC. It is intended for appropriate control circuit duties rather than use as an additional 9 A motor power contact.

How is the Finder 6K.04.8.024.4709 mounted?

The contactor mounts onto a standard 35 mm DIN rail in accordance with EN 60715. Its compact 45 mm-wide housing supports installation in industrial control panels and electrical cabinets.

What is the difference between Finder 6K.04.8.024.4709 and 6K.04.8.024.4312?

The 6K.04.8.024.4709 has a 9 A AC-3 rating, a 4 kW motor rating and a 3 NO + 1 NC contact arrangement with an auxiliary mirror contact. The 6K.04.8.024.4312 belongs to the 12 A AC-3, 5.5 kW version and has four normally open contacts. They are not direct substitutes without checking the electrical ratings and contact arrangement.

What is the operating temperature range?

The Finder 6K.04.8.024.4709 is specified for an ambient operating temperature range of −40 to +70 °C, subject to the manufacturer's applicable installation and electrical loading conditions.

Can this contactor be used in a safety-related motor control circuit?

The normally closed mirror contact can support monitoring in suitably designed safety-related control systems. However, the contactor alone does not establish a safety performance level. The complete system must be designed and validated using the relevant safety standards, protective devices and diagnostic arrangements.

Trusted by Industrial Automation and Electrical Equipment Manufacturers

Finder Series 6K industrial contactors provide compact and dependable switching solutions for motor control, industrial machinery and electrical distribution equipment. Their AgSnO₂ contacts, DIN rail mounting, defined AC-3 motor ratings and available mirror auxiliary contact configurations make them a practical choice for engineers, panel builders and OEM manufacturers developing reliable industrial electrical control systems.