Lovato BFK8000A230 three-pole power factor correction contactor with AC control circuit, built-in limiting resistors, 50 kvar rating at 400 V and 230 V AC 50/60 Hz coil for capacitor bank switching applications.
£223.34
The Lovato BFK8000A230 is a heavy-duty three-pole power factor correction contactor designed for capacitor bank switching in industrial electrical panels, reactive power compensation systems and automatic power factor correction assemblies. As part of the Lovato BFK80 series, it is purpose-built for AC-6b capacitor switching duty and includes limiting resistors to help reduce high inrush current when capacitor stages are energised.
This contactor is rated for a maximum IEC operational power of 50 kvar at 400 V, with additional capacitor switching ratings of 30 kvar at 230 V, 56 kvar at 440 to 480 V and 65 kvar at 690 V. It uses a 230 V AC 50/60 Hz coil, making it suitable for standard industrial AC control circuits used in capacitor bank and power factor correction panels.
With 3 normally open main poles, 115 A conventional free air thermal current, screw or 35 mm DIN rail mounting, IP20 front terminal protection and recognised international approvals, the BFK8000A230 is a dependable choice for larger capacitor switching stages where controlled inrush performance, high making capacity and long operating life are required.
Power factor correction contactors are designed to switch capacitor stages safely and repeatedly in automatic capacitor banks. When capacitors are energised, high transient inrush current can occur. The Lovato BFK8000A230 uses built-in limiting resistors to help reduce these current peaks, supporting longer contactor life and more stable capacitor bank operation.
The 50 kvar at 400 V rating makes this model suitable for larger capacitor bank stages where high making capacity, controlled inrush limitation and reliable AC control operation are required. Its 230 V AC 50/60 Hz coil, BFK80 frame, 800 A RMS making capacity and IP20 front protection make it straightforward to integrate into professional power factor correction panels.
Tick the specs you need, then view products that match.
| Coil Voltage Range | 200–250 V | |
|---|---|---|
| Device Type | Capacitor Switching Contactor | |
| Voltage | 230 V | |
| Phase | Three Phase | |
| Poles | 3-pole | |
| Coil / Supply Voltage | 230 V AC | |
| Auxiliary Contacts | None | |
| Coil Type | AC | |
| Current AC-1 | 115 A | |
| Series | BFK80 | |
| Product designation | Power contactor | |
| Product type | Contactor for power factor correction with AC control circuit | |
| Application | Capacitor bank and power factor correction switching | |
| Number of poles | 3 | |
| Main contact configuration | 3 NO | |
| Type of coil | AC coil 50/60 Hz | |
| Rated coil voltage | 230 V AC at 50/60 Hz | |
| Operational frequency | 25 to 400 Hz | |
| IEC operational power at 230 V | 30 kvar | |
| IEC operational power at 400 V | 50 kvar | |
| IEC operational power at 440 to 480 V | 56 kvar | |
| IEC operational power at 690 V | 65 kvar | |
| IEC conventional free air thermal current Ith | 115 A at ≤40 °C | |
| Rated insulation voltage Ui | 690 V | |
| Rated impulse withstand voltage Uimp | 8 kV | |
| Short-time allowable current | 640 A for 10 s | |
| Protection fuse | 125 A gG | |
| Making capacity | 800 A RMS | |
| Breaking capacity | 640 A at 440 V, 625 A at 500 V, 456 A at 690 V | |
| Average resistance per pole | 0.6 mΩ | |
| Power dissipation per pole at Ith | 7.9 W | |
| Terminal tightening torque | 4 to 5 Nm | |
| Coil terminal tightening torque | 0.8 to 1 Nm | |
| Maximum connectable wires per terminal | 2 | |
| Maximum conductor section | 2 AWG/kcmil | |
| Flexible conductor section without lug | 1.5 to 35 mm² | |
| Flexible conductor section with lug | 1.5 to 35 mm² | |
| Power terminal protection | IP20 front | |
| Operating position | Vertical plane, allowable ±30° | |
| Mounting type | Screw fixing / 35 mm DIN rail | |
| Weight | 1090 g | |
| Mechanical life | 15,000,000 cycles | |
| Electrical life | 400,000 cycles | |
| B10d rated load cycles | 400,000 | |
| B10d mechanical load cycles | 15,000,000 | |
| Maximum mechanical operating frequency | 3,600 cycles/h | |
| AC coil operating range at 50 Hz | 80 to 110% Us pick-up, 20 to 55% Us drop-out | |
| AC coil operating range at 60 Hz | 85 to 110% Us pick-up, 20 to 55% Us drop-out | |
| AC coil consumption at 50 Hz | 210 VA inrush, 15 VA holding | |
| AC coil consumption at 60 Hz | 195 VA inrush, 13 VA holding | |
| Dissipation at holding | 5 W at 50 Hz | |
| Average AC closing time | 12 to 28 ms | |
| Average AC opening time | 8 to 22 ms | |
| UL rated operational voltage | 600 V AC | |
| UL general use current | 115 A | |
| Operating temperature | -50 °C to +70 °C | |
| Storage temperature | -60 °C to +80 °C | |
| Maximum altitude | 3,000 m | |
| Pollution degree | 3 | |
| EMC compatibility | Yes | |
| ETIM classification | EC001079 - Capacitor contactor | |
| Package quantity | 5 | |
| Package dimensions | 313 x 188 x 155 mm | |
| Package volume | 1824 cm³ | |
| EAN | 8013975224724 | |
| Certifications | CCC, cULus | |
| Standards | IEC/EN/BS 60947-1, IEC/EN/BS 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1 | |
| HS Code | 85365080 |
The Lovato BFK8000A230 is used for switching capacitors in automatic power factor correction systems, reactive power compensation panels and industrial capacitor bank assemblies.
It is rated for 50 kvar at 400 V. It is also rated at 30 kvar at 230 V, 56 kvar at 440 to 480 V and 65 kvar at 690 V for AC-6b capacitor switching duty.
The BFK8000A230 uses a 230 V AC 50/60 Hz coil, making it suitable for standard AC control circuits in power factor correction panels.
Yes. The contactor includes limiting resistors to help reduce capacitor inrush current when capacitor stages are switched on.
The BFK8000A230 has an 800 A RMS making capacity, supporting reliable switching of capacitor stages with controlled inrush current.
It can be installed using screw fixing or mounted on a standard 35 mm DIN rail, making it suitable for capacitor bank panels and electrical control cabinets.
Lovato BFK capacitor switching contactors are trusted by panel builders, facilities engineers and energy management specialists for dependable power factor correction, controlled capacitor inrush switching and robust operation in industrial electrical systems.