BFK2600A110 - 3P CONTACTOR 20KVAR 110V 50/60HZ

BFK2600A110 – 3P CONTACTOR 20KVAR 110V 50/60HZ

Lovato BFK2600A110 three-pole power factor correction contactor with AC control circuit, built-in limiting resistors, 20 kvar rating at 400 V and 110 V AC 50/60 Hz coil for capacitor bank switching applications.

SKU: BFK2600A110MPN: BFK2600A110
Price
List Price £147.25 ex VAT
Your Price (ex VAT) Save 40%
£88.35 40% OFF
You save £58.90 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £88.35
Trade pricing is personalised to your account

Manufacturer Lead Time

£88.35

Why Choose the Lovato BFK2600A110 Power Factor Correction Contactor?

The Lovato BFK2600A110 is a compact and reliable three-pole power factor correction contactor designed for controlled capacitor bank switching in industrial electrical panels, reactive power compensation systems and automatic power factor correction assemblies. As part of the Lovato BFK26 series, it is purpose-built for AC-6b capacitor switching duties and includes limiting resistors to help reduce high inrush current when capacitor stages are energised.

This contactor is rated for a maximum IEC operational power of 20 kvar at 400 V, with additional capacitor switching ratings of 11 kvar at 230 V, 22 kvar at 440 to 480 V and 25 kvar at 690 V. It uses a 110 V AC 50/60 Hz coil, making it suitable for industrial control circuits used in automatic capacitor bank panels.

With 3 normally open main poles, 45 A conventional free air thermal current, screw or 35 mm DIN rail mounting, IP20 terminal protection when correctly wired and recognised international approvals, the BFK2600A110 is a dependable choice for medium capacitor switching stages where compact size, controlled inrush performance and long service life are required.

Key Advantages

  • Purpose-built capacitor switching contactor for power factor correction systems.
  • 20 kvar at 400 V maximum IEC operational power rating.
  • Integrated limiting resistors help reduce capacitor inrush current.
  • 110 V AC 50/60 Hz coil for industrial AC control circuits.
  • 3-pole design with normally open main contacts.
  • 45 A conventional free air thermal current for capacitor switching assemblies.
  • 1.6 million electrical cycles and 20 million mechanical cycles.
  • Suitable for screw fixing or 35 mm DIN rail mounting.
  • Certified to major IEC, EN, BS, UL and CSA contactor standards.

Key Features

  • Lovato BFK26 series capacitor switching contactor.
  • AC control circuit with built-in limiting resistors.
  • Rated operational power: 20 kvar at 400 V AC-6b.
  • Number of poles: 3.
  • Main contact configuration: 3 normally open contacts.
  • Built-in auxiliary contacts: 0.
  • Rated coil voltage: 110 V AC at 50/60 Hz.
  • Conventional free air thermal current Ith: 45 A.
  • Rated insulation voltage Ui: 690 V.
  • Rated impulse withstand voltage Uimp: 6 kV.
  • Making capacity: 260 A RMS.
  • Power terminal protection: IP20 when correctly wired.
  • Fixing: screw mounting or 35 mm DIN rail.

Reliable Capacitor Switching for Power Factor Correction Panels

Power factor correction contactors are designed to switch capacitor stages safely and repeatedly in automatic capacitor banks. When capacitors are energised, high transient inrush current can occur. The Lovato BFK2600A110 uses built-in limiting resistors to help reduce these current peaks, supporting longer contactor life and more stable capacitor bank operation.

The 20 kvar at 400 V rating makes this model suitable for medium capacitor bank stages where compact installation, reliable AC control operation and repeatable switching performance are required. Its 110 V AC 50/60 Hz coil, BFK26 frame, high electrical endurance and IP20 front protection make it straightforward to integrate into professional power factor correction panels.

Typical Applications

  • Automatic power factor correction capacitor banks.
  • Reactive power compensation panels.
  • Industrial electrical distribution systems.
  • Capacitor switching stages up to 20 kvar at 400 V.
  • Commercial and industrial energy management systems.
  • Low-voltage switchgear and control panels.
  • OEM power factor correction equipment.
  • Installations requiring a 110 V AC control coil.

Technical Specifications

Tick the specs you need, then view products that match.

Coil Voltage Range 100–130 V
Device Type Capacitor Switching Contactor
Voltage 110 V
Phase Three Phase
Poles 3-pole
Coil / Supply Voltage 110 V AC
Auxiliary Contacts None
Coil Type AC
Current AC-1 45 A
Series BFK26
Product designation Power contactor
Product type Contactor for power factor correction with AC control circuit
Application Capacitor bank and power factor correction switching
Number of poles 3
Main contact configuration 3 NO
Type of coil AC coil 50/60 Hz
Rated coil voltage 110 V AC at 50/60 Hz
Operational frequency 25 to 400 Hz
IEC operational power at 230 V 11 kvar
IEC operational power at 400 V 20 kvar
IEC operational power at 440 to 480 V 22 kvar
IEC operational power at 690 V 25 kvar
IEC conventional free air thermal current Ith 45 A at ≤40 °C
Rated insulation voltage Ui 690 V
Rated impulse withstand voltage Uimp 6 kV
Short-time allowable current 210 A for 10 s
Protection fuse 40 A gG
Making capacity 260 A RMS
Breaking capacity 208 A at 440 V, 184 A at 500 V, 168 A at 690 V
Average resistance per pole 2 mΩ
Power dissipation per pole at Ith 4 W
Terminal tightening torque 2.5 to 3 Nm
Coil terminal tightening torque 0.8 to 1 Nm
Maximum connectable wires per terminal 2
Maximum conductor section 6 AWG/kcmil
Flexible conductor section without lug 2.5 to 16 mm²
Flexible conductor section with lug 1 to 10 mm²
Flexible conductor section with insulated spade lug 1 to 10 mm²
Power terminal protection IP20 when properly wired
Operating position Vertical plane, allowable ±30°
Mounting type Screw fixing / 35 mm DIN rail
Weight 480 g
Mechanical life 20,000,000 cycles
Electrical life 1,600,000 cycles
B10d rated load cycles 400,000
B10d mechanical load cycles 20,000,000
Maximum mechanical operating frequency 3,600 cycles/h
AC coil operating range at 50 Hz 80 to 110% Us pick-up, 20 to 55% Us drop-out
AC coil operating range at 60 Hz 85 to 110% Us pick-up, 20 to 55% Us drop-out
AC coil consumption at 50 Hz 75 VA inrush, 9 VA holding
AC coil consumption at 60 Hz 70 VA inrush, 7 VA holding
Holding dissipation 2.5 W at 50 Hz
Average closing time 8 to 24 ms
Average opening time 5 to 15 ms
UL general use current 45 A
Operating temperature -50 °C to +70 °C
Storage temperature -60 °C to +80 °C
Maximum altitude 3,000 m
Pollution degree 3
EMC compatibility Yes
ETIM classification EC001079 - Capacitor contactor
Package quantity 10
Package dimensions 265 x 265 x 135 mm
Package volume 948.038 cm³
EAN 8013975163399
Certifications CCC, EAC, cULus
Standards IEC/EN/BS 60947-1, IEC/EN/BS 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
HS Code 85365080

Frequently Asked Questions

What is the Lovato BFK2600A110 used for?

The Lovato BFK2600A110 is used for switching capacitors in automatic power factor correction systems, reactive power compensation panels and industrial capacitor bank assemblies.

What is the kvar rating of the BFK2600A110?

It is rated for 20 kvar at 400 V. It is also rated at 11 kvar at 230 V, 22 kvar at 440 to 480 V and 25 kvar at 690 V for AC-6b capacitor switching duty.

What coil voltage does this contactor use?

The BFK2600A110 uses a 110 V AC 50/60 Hz coil, making it suitable for compatible AC control circuits in power factor correction panels.

Does the BFK2600A110 include limiting resistors?

Yes. The contactor includes limiting resistors to help reduce capacitor inrush current when capacitor stages are switched on.

Does this contactor include auxiliary contacts?

No. This BFK2600A110 variant has 0 built-in auxiliary contacts. External auxiliary contact blocks may be selected separately where signalling or interlocking is required.

How is the Lovato BFK2600A110 mounted?

It can be installed using screw fixing or mounted on a standard 35 mm DIN rail, making it suitable for capacitor bank panels and electrical control cabinets.