Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Lovato BFK1810A57560 is a three-pole power factor correction contactor with limiting resistors, rated at 15 kvar at 400 V AC-6b and fitted with a 575 V AC 60 Hz coil for capacitor bank switching.
£57.30
The Lovato BFK1810A57560 is a specialised three-pole power factor correction contactor designed for reliable switching of capacitor banks in industrial and commercial electrical installations. As part of the Lovato BFK18 contactor series, it is specifically engineered for capacitor switching duties and incorporates limiting resistors to reduce the high inrush currents associated with energising capacitors.
The BFK1810A57560 provides a maximum IEC operational power rating of 15 kvar at 400 V and features a dedicated 575 V AC 60 Hz coil. Its three normally open main contacts provide three-phase capacitor switching, while the dedicated BFK construction makes it suitable for automatic power factor correction equipment.
With a conventional free-air thermal current of 32 A, rated insulation voltage of 690 V and rated impulse withstand voltage of 6 kV, the BFK1810A57560 is engineered for demanding low-voltage installations. Its screw-connected main circuit provides secure termination for integration into power factor correction panels and electrical control cabinets.
Power factor correction contactors such as the Lovato BFK1810A57560 are specifically engineered for switching capacitor stages in reactive power compensation systems. Capacitors can generate substantial transient inrush currents when energised, so the BFK design incorporates limiting resistors that help reduce these current peaks and the resulting electrical stress during switching.
The BFK1810A57560 provides 15 kvar at 400 V AC-6b and combines dedicated capacitor switching characteristics with a 575 V AC 60 Hz coil. Its three-pole configuration and robust electrical ratings make it suitable for automatic power factor correction equipment in industrial and commercial installations.
Tick the specs you need, then view products that match.
| Coil Voltage Range | 575–600 V | |
|---|---|---|
| Device Type | Capacitor Switching Contactor | |
| Poles | 3-pole | |
| Coil / Supply Voltage | 575 V AC | |
| Coil Type | AC | |
| Current AC-1 | 32 A | |
| HS Code | 85365080 | |
| Manufacturer | Lovato Electric | |
| Series | BFK18 | |
| Model | BFK1810A57560 | |
| Product type | Contactor for power factor correction with AC control circuit | |
| Number of poles | 3 | |
| Main contact configuration | 3NO | |
| Coil type | AC coil, 60 Hz | |
| Rated coil voltage | 575 V AC | |
| Rated operational power AC-6b at 230 V | 9 kvar | |
| Rated operational power AC-6b at 400 V | 15 kvar | |
| Rated operational power AC-6b at 500 V | 17 kvar | |
| Rated operational power AC-6b at 690 V | 20 kvar | |
| IEC conventional free-air thermal current Ith | 32 A | |
| Rated insulation voltage Ui | 690 V | |
| Rated impulse withstand voltage Uimp | 6 kV | |
| Operational frequency | 25–400 Hz | |
| Short-time allowable current for 10 s | 200 A | |
| Recommended gG protection fuse | 40 A | |
| Resistance per pole | 2.5 mΩ | |
| Main terminal tightening torque | 1.5–1.8 Nm | |
| Coil terminal tightening torque | 0.8–1 Nm | |
| Power terminal protection | IP20 when wired | |
| Main circuit connection | Screw connection | |
| Weight | 0.42 kg | |
| EAN | 8013975163368 |
The BFK1810A57560 is a three-pole contactor designed specifically for switching capacitor banks in power factor correction and reactive power compensation systems.
The BFK1810A57560 has an IEC AC-6b rated operational power of 15 kvar at 400 V.
The BFK1810A57560 uses a dedicated 575 V AC 60 Hz coil for operation from compatible 60 Hz AC control circuits.
Yes. The BFK1810A57560 incorporates limiting resistors designed to reduce the high inrush current associated with capacitor switching.
The contactor is rated at 9 kvar at 230 V, 15 kvar at 400 V, 17 kvar at 500 V and 20 kvar at 690 V under IEC AC-6b duty.
Lovato Electric BFK contactors are purpose-designed for capacitor switching in power factor correction systems, combining inrush-current limiting resistors with dependable electrical performance for industrial and commercial installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.