Lovato BF26T4A02460 four-pole BF26 power contactor with 4 normally open contacts, 45 A AC-1 conventional thermal current, 26 A AC-3 operating current, 24 V AC 60 Hz coil and screw or 35 mm DIN rail mounting for industrial control panels and automation systems.
£82.36
The Lovato BF26T4A02460 is a compact and robust four-pole power contactor designed for industrial load switching, control panels, machinery and automation systems. Part of the Lovato Electric BF contactor range, it provides dependable switching performance with a 4 normally open contact configuration.
This BF26 contactor has an IEC conventional thermal current Ith of 45 A in AC-1 duty and an IEC AC-3 operating current of 26 A at up to 440 V, making it suitable for resistive loads, lightly inductive loads and selected motor switching applications. Its 24 V AC 60 Hz coil is designed for low-voltage AC control circuits used in machine control, HVAC panels, industrial distribution and OEM electrical assemblies.
The BF26T4A02460 is designed for straightforward installation using screw fixing or 35 mm DIN rail mounting. With recognised international approvals, IP20 terminal protection when correctly wired, long mechanical life and compatibility with Lovato BF series accessories, it is a practical choice for professional panel builders requiring a four-pole normally open contactor.
The Lovato BF26T4A02460 provides four normally open main poles that close together when the 24 V AC 60 Hz coil is energised. This configuration is suitable for switching multiple lines or circuits from one coil command, subject to the required protection, load category and installation design.
With its 45 A AC-1 rating, 26 A AC-3 operating current, IP20 terminal protection and compact BF26 frame, the BF26T4A02460 is well suited to machine control panels, HVAC systems, automation assemblies and OEM equipment where a reliable four-pole normally open contactor is specified.
Tick the specs you need, then view products that match.
| Terminal Type | Screw | |
|---|---|---|
| Coil Voltage Range | 24 V | |
| Current AC-1 | 45 A | |
| Device Type | Contactor | |
| Current | 26 A | |
| Power | 13 kW | |
| Voltage | 24 V | |
| Phase | Three Phase | |
| Poles | 4-pole | |
| Coil / Supply Voltage | 24 V AC | |
| Coil Type | AC | |
| Series | BF Series | |
| Product designation | Power contactor | |
| Product type designation | BF26 | |
| Number of poles | 4 | |
| Contact configuration | 4 normally open main contacts | |
| Coil type | AC coil, 60 Hz | |
| Rated coil voltage | 24 V AC | |
| Rated insulation voltage Ui | 690 V | |
| Rated impulse withstand voltage Uimp | 6 kV | |
| Operational frequency | 25 to 400 Hz | |
| IEC conventional free air thermal current Ith | 45 A at 40 °C or below | |
| IEC AC-1 operating current | 45 A at 40 °C or below, 36 A at 55 °C or below, 32 A at 70 °C or below | |
| IEC AC-3 operating current | 26 A at up to 440 V and 55 °C or below | |
| IEC AC-3 rated power at 400 V | 13 kW | |
| IEC AC-4 operating current at 400 V | 11.5 A | |
| Rated operational power AC-1 at 230 V | 17 kW | |
| Rated operational power AC-1 at 400 V | 30 kW | |
| Rated operational power AC-1 at 500 V | 37 kW | |
| Rated operational power AC-1 at 690 V | 51 kW | |
| IEC DC-1 current with 1 pole in series | 25 A at 24 V or below, 21 A at 48 V, 18 A at 75 V, 6 A at 110 V | |
| IEC DC-1 current with 2 poles in series | 28 A at 24 V or below, 28 A at 48 V, 25 A at 75 V, 22 A at 110 V, 2 A at 220 V | |
| IEC DC-1 current with 3 poles in series | 28 A at 24 V or below, 28 A at 48 V, 25 A at 75 V, 24 A at 110 V, 20 A at 220 V | |
| IEC DC-1 current with 4 poles in series | 28 A at 24 V or below, 28 A at 48 V, 25 A at 75 V, 24 A at 110 V, 26 A at 220 V | |
| IEC DC-3/DC-5 current with 1 pole in series | 18 A at 24 V or below, 15 A at 48 V, 13 A at 75 V, 2 A at 110 V | |
| IEC DC-3/DC-5 current with 2 poles in series | 20 A at 24 V or below, 20 A at 48 V, 18 A at 75 V, 13 A at 110 V, 3 A at 220 V | |
| IEC DC-3/DC-5 current with 3 poles in series | 25 A at 24 V or below, 25 A at 48 V, 20 A at 75 V, 18 A at 110 V, 19 A at 220 V | |
| IEC DC-3/DC-5 current with 4 poles in series | 30 A at 24 V or below, 30 A at 48 V, 25 A at 75 V, 20 A at 110 V, 15 A at 220 V | |
| Short-time allowable current for 10 s | 210 A | |
| Protection fuse gG | 50 A | |
| Protection fuse aM | 32 A | |
| Making capacity | 260 A RMS | |
| Breaking capacity at 440 V | 208 A | |
| Breaking capacity at 500 V | 184 A | |
| Breaking capacity at 690 V | 168 A | |
| Resistance per pole | 2 mΩ average | |
| Power dissipation per pole at Ith | 4 W | |
| Power dissipation per pole at AC-3 | 1.4 W | |
| Power terminal protection | IP20 when correctly wired | |
| Terminal style | Screw terminals | |
| Terminal tightening torque | 2.5 to 3 Nm | |
| Coil terminal tightening torque | 0.8 to 1 Nm | |
| Maximum number of wires simultaneously connectable | 2 | |
| Maximum conductor size | AWG 6 | |
| Flexible conductor section without lug | 2.5 to 16 mm² | |
| Flexible conductor section with lug | 1 to 10 mm² | |
| Flexible conductor section with insulated spade lug | 1 to 16 mm² | |
| Main circuit cable stripping length | 10 mm | |
| Command circuit cable stripping length | 8 mm | |
| Mounting type | Screw fixing or 35 mm DIN rail | |
| Operating position | Vertical plane, allowable plus or minus 30° | |
| Mechanical life | 20,000,000 cycles | |
| Electrical life | 1,600,000 cycles | |
| Safety related B10d at rated load | 1,600,000 cycles | |
| Safety related B10d mechanical load | 20,000,000 cycles | |
| AC coil pick-up range at 60 Hz | 80 to 110% Us | |
| AC coil drop-out range at 60 Hz | 20 to 55% Us | |
| Average coil consumption at 60 Hz | 75 VA inrush, 9 VA holding | |
| Holding dissipation | 2.5 W | |
| Maximum mechanical operating frequency | 3600 cycles per hour | |
| AC closing time, NO contact | 8 to 24 ms | |
| AC opening time, NO contact | 5 to 15 ms | |
| AC closing time, NC contact | 9 to 20 ms | |
| AC opening time, NC contact | 9 to 17 ms | |
| UL rated operational voltage | 600 V AC | |
| UL full-load current at 480 V | 21 A | |
| UL full-load current at 600 V | 22 A | |
| UL/CSA horsepower rating at 110/120 V single-phase | 2 HP | |
| UL/CSA horsepower rating at 230 V single-phase | 5 HP | |
| UL/CSA horsepower rating at 200/208 V three-phase | 7.5 HP | |
| UL/CSA horsepower rating at 220/240 V three-phase | 7.5 HP | |
| UL/CSA horsepower rating at 460/480 V three-phase | 15 HP | |
| UL/CSA horsepower rating at 575/600 V three-phase | 20 HP | |
| UL general use current | 45 A | |
| High fault short-circuit protection | 100 kA with 100 A Class J fuse at 600 V | |
| Standard fault short-circuit protection | 5 kA with 100 A fuse at 600 V | |
| Operating temperature | -50 to +70 °C | |
| Storage temperature | -60 to +80 °C | |
| Maximum altitude | 3000 m | |
| Pollution degree | 3 | |
| EMC compatibility | Yes | |
| ETIM classification | EC000066 - Power contactor, AC switching | |
| Weight | 508 g | |
| Package dimensions | 97 x 65 x 90 mm | |
| Package volume | 567.45 cm³ | |
| EAN | 8013975161746 | |
| Certifications | CCC, EAC, cULus, UL 60335-2-40 LZGH A2L, CSA C22.2 No. 60335-2-40:22 LZGH A2L, UL 60335-2-89 LZGH A2L and CSA C22.2 No. 60335-2-89:21 LZGH A2L | |
| Standards | IEC/EN/BS 60947-1, IEC/EN/BS 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1 and IEC/EN 60335-2-89 | |
| HS Code | 85365080 |
The Lovato BF26T4A02460 is used for industrial switching applications where a four-pole contactor with 4 normally open contacts and a 24 V AC 60 Hz control coil is required.
The BF26T4A02460 has 4 poles, arranged as 4 normally open main contacts.
It has an IEC conventional thermal current Ith AC-1 rating of 45 A and an IEC AC-3 operating current rating of 26 A at up to 440 V.
The BF26T4A02460 uses a 24 V AC coil designed for 60 Hz control circuits.
At 60 Hz, the coil consumes approximately 75 VA inrush and 9 VA holding.
The contactor can be mounted by screw fixing or on a standard 35 mm DIN rail inside an electrical control panel.
4NO means the contactor has four normally open contacts. These contacts are open when the coil is not energised and close when the coil is energised.
Lovato BF series contactors are widely used by electrical engineers, OEMs and panel builders for reliable switching, compact installation and professional integration into industrial control systems.