BF26T2D048 - 4P CONTACTOR 2NO+2NC 45A AC1 48VDC

BF26T2D048 – 4P CONTACTOR 2NO+2NC 45A AC1 48VDC

Lovato BF26T2D048 four-pole BF26 contactor with 2 normally open and 2 normally closed contacts, 45 A AC-1 conventional thermal current, 26 A AC-3 operating current, 48 V DC coil and screw or 35 mm DIN rail mounting for industrial control panels and automation systems.

SKU: BF26T2D048MPN: BF26T2D048
Price
List Price £236.98 ex VAT
Your Price (ex VAT) Save 40%
£142.19 40% OFF
You save £94.79 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £142.19
Trade pricing is personalised to your account

Manufacturer Lead Time

£142.19

Why Choose the Lovato BF26T2D048 Four-Pole Contactor?

The Lovato BF26T2D048 is a compact and robust four-pole contactor designed for industrial load switching, control panels, machinery and automation systems. Part of the Lovato Electric BF contactor range, it provides dependable switching performance with a 2 normally open and 2 normally closed contact configuration.

This BF26 contactor has an IEC conventional thermal current Ith of 45 A in AC-1 duty and an IEC AC-3 operating current of 26 A at up to 440 V, making it suitable for resistive loads, lightly inductive loads and selected motor switching applications. Its 48 V DC coil is suitable for DC control circuits, automation panels, battery-backed systems and OEM electrical assemblies.

The BF26T2D048 is designed for straightforward installation using screw fixing or 35 mm DIN rail mounting. With recognised international approvals, IP20 terminal protection when correctly wired, long mechanical life and compatibility with Lovato BF series accessories, it is a practical choice for professional panel builders requiring a four-pole contactor with mixed NO and NC contacts.

Key Advantages

  • Compact four-pole contactor for industrial power and control switching.
  • 2 normally open and 2 normally closed main contacts for mixed switching requirements.
  • 45 A AC-1 conventional thermal current for suitable resistive and lightly inductive loads.
  • 26 A AC-3 operating current at up to 440 V for suitable motor switching duties.
  • 48 V DC coil for DC control circuits and automation panels.
  • 15 HP UL/CSA rating at 460/480 V for applicable three-phase load applications.
  • Screw or 35 mm DIN rail mounting for flexible panel installation.
  • Compatible with Lovato BF series auxiliary contacts, surge suppressors, interlocks and connection accessories.

Key Features

  • Lovato Electric BF26 four-pole contactor.
  • Contact configuration: 2 normally open and 2 normally closed poles.
  • IEC AC-1 thermal current: 45 A.
  • IEC AC-3 operating current: 26 A at up to 440 V.
  • Rated coil voltage: 48 V DC.
  • Coil type: DC coil.
  • DC coil consumption: 5.4 W inrush and holding.
  • Rated insulation voltage: 690 V IEC/EN.
  • Rated impulse withstand voltage: 6 kV.
  • UL/CSA horsepower rating: 15 HP at 460/480 V three-phase.
  • DIN rail or screw mounting for control panel use.

Mixed NO and NC Switching with a 48 V DC Coil

The Lovato BF26T2D048 combines two normally open contacts and two normally closed contacts in one compact contactor. This mixed configuration allows circuits to be switched in opposite states from the same coil operation, supporting control, changeover-style logic and load switching tasks within industrial electrical panels.

With its 48 V DC coil, 45 A AC-1 rating and 26 A AC-3 operating current, the BF26T2D048 is well suited to DC control systems, battery-backed panels, machine control assemblies, HVAC systems and OEM equipment where a compact four-pole contactor with mixed contacts is specified.

Typical Applications

  • Industrial control panels requiring two normally open and two normally closed switching poles.
  • AC-1 resistive and lightly inductive load switching circuits.
  • 48 V DC control circuits and battery-backed panels.
  • Motor control circuits requiring BF26 contactor performance.
  • HVAC, refrigeration and plant control equipment.
  • Machine control and OEM electrical assemblies.
  • Distribution, isolation and control circuit integration.

Technical Specifications

Tick the specs you need, then view products that match.

Terminal Type Screw
Coil Voltage Range 42–48 V
Current AC-1 45 A
Device Type Contactor
Current 26 A
Power 30 kW
Voltage 48 V
Phase Three Phase
Poles 4-pole
Coil / Supply Voltage 48 V DC
Coil Type DC
Series BF Series
Product designation Power contactor
Product type designation BF26
Number of poles 4
Contact configuration 2 normally open and 2 normally closed main contacts
Coil type DC coil
Rated coil voltage 48 V DC
DC operating voltage pick-up range 80 to 125% Us
DC operating voltage drop-out range 10 to 40% Us
Average coil consumption at 20 °C 5.4 W inrush, 5.4 W holding
Rated insulation voltage Ui 690 V
Rated impulse withstand voltage Uimp 6 kV
Operational frequency 25 to 400 Hz
IEC conventional free air thermal current Ith 45 A at 40 °C or below
IEC AC-1 operating current 45 A at 40 °C or below, 36 A at 55 °C or below, 32 A at 70 °C or below
IEC AC-3 operating current 26 A at up to 440 V and 55 °C or below
IEC AC-4 operating current at 400 V 11.5 A
Rated operational power AC-1 at 230 V 17 kW
Rated operational power AC-1 at 400 V 30 kW
Rated operational power AC-1 at 500 V 37 kW
Rated operational power AC-1 at 690 V 51 kW
Short-time allowable current for 10 s 210 A
Protection fuse gG 50 A
Protection fuse aM 32 A
Making capacity 260 A RMS
Breaking capacity at 440 V 208 A
Breaking capacity at 500 V 184 A
Breaking capacity at 690 V 168 A
Resistance per pole 2 mΩ average
Power dissipation per pole at Ith 4 W
Power dissipation per pole at AC-3 1.4 W
Power terminal protection IP20 when correctly wired
Terminal style Screw terminals
Terminal tightening torque 2.5 to 3 Nm
Coil terminal tightening torque 0.8 to 1 Nm
Maximum number of wires simultaneously connectable 2
Flexible conductor section without lug 2.5 to 16 mm²
Flexible conductor section with lug 1 to 10 mm²
Main circuit cable stripping length 10 mm
Command circuit cable stripping length 8 mm
Mounting type Screw fixing or 35 mm DIN rail
Operating position Vertical plane, allowable plus or minus 30°
Mechanical life 20,000,000 cycles
Electrical life 1,600,000 cycles
Maximum mechanical operating frequency 3600 cycles per hour
DC closing time, NO contact 54 to 66 ms
DC opening time, NO contact 14 to 17 ms
DC closing time, NC contact 23 to 28 ms
DC opening time, NC contact 46 to 56 ms
UL rated operational voltage 600 V AC
UL full-load current at 480 V 21 A
UL full-load current at 600 V 22 A
UL/CSA horsepower rating at 110/120 V single-phase 2 HP
UL/CSA horsepower rating at 230 V single-phase 5 HP
UL/CSA horsepower rating at 200/208 V three-phase 7.5 HP
UL/CSA horsepower rating at 220/240 V three-phase 7.5 HP
UL/CSA horsepower rating at 460/480 V three-phase 15 HP
UL/CSA horsepower rating at 575/600 V three-phase 20 HP
Operating temperature -50 to +70 °C
Storage temperature -60 to +80 °C
Maximum altitude 3000 m
Pollution degree 3
EMC compatibility Yes
Approximate width 76 mm
Approximate height 100 mm
Approximate depth 115 mm
Weight 670 g
Package dimensions 100 x 76 x 115 mm
Package volume 874 cm³
EAN 8013975167113
Certifications CCC, EAC, cULus, UL 60335-2-40 LZGH A2L, CSA C22.2 No. 60335-2-40:22 LZGH A2L, UL 60335-2-89 LZGH A2L and CSA C22.2 No. 60335-2-89:21 LZGH A2L
Standards IEC/EN/BS 60947-1, IEC/EN/BS 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1 and IEC/EN 60335-2-89
HS Code 85365080

Frequently Asked Questions

What is the Lovato BF26T2D048 used for?

The Lovato BF26T2D048 is used for industrial switching applications where a four-pole contactor with 2 normally open and 2 normally closed contacts and a 48 V DC control coil is required.

How many poles does the BF26T2D048 have?

The BF26T2D048 has 4 poles, arranged as 2 normally open and 2 normally closed main contacts.

What current rating does the BF26T2D048 have?

It has an IEC conventional thermal current Ith AC-1 rating of 45 A and an IEC AC-3 operating current rating of 26 A at up to 440 V.

What coil voltage does this contactor use?

The BF26T2D048 uses a 48 V DC coil, making it suitable for DC control circuits, automation panels and battery-backed systems.

How much power does the DC coil consume?

The 48 V DC coil consumes approximately 5.4 W for both inrush and holding operation.

How is the Lovato BF26T2D048 mounted?

The contactor can be mounted by screw fixing or on a standard 35 mm DIN rail inside an electrical control panel.

What does 2NO and 2NC mean on this contactor?

2NO and 2NC means the contactor has two normally open contacts and two normally closed contacts. The normally open contacts close when the coil is energised, while the normally closed contacts open when the coil is energised.

Trusted by Panel Builders and Automation Engineers

Lovato BF series contactors are widely used by electrical engineers, OEMs and panel builders for reliable switching, compact installation and professional integration into industrial control systems.