22.44.0.120.4717 Finder contactor 4 pole 40A AC/DC 110/125V NO

22.44.0.120.4717 Finder contactor 4 pole 40A AC/DC 110/125V NO

Finder 22.44.0.120.4717 Series 22 four-pole modular installation contactor with a 40 A rated contact current, 110–120 V AC / 110 V DC control coil, 3 NO + 1 NC mirror-contact configuration, integrated varistor protection and DIN rail mounting for industrial power switching and monitored electrical control.

SKU: 22.44.0.120.4717Alt SKU: 224401204717MPN: 22.44.0.120.4717
Price
List Price £85.16 ex VAT
Your Price (ex VAT) Save 30%
£59.61 30% OFF
You save £25.55 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £59.61
Trade pricing is personalised to your account

Manufacturer Lead Time

£59.61

Why Choose the Finder 22.44.0.120.4717 Modular Installation Contactor?

The Finder 22.44.0.120.4717 is a high-performance 40 A four-pole modular installation contactor designed for reliable switching of electrical loads in commercial buildings, industrial installations and automated control systems. Part of the Finder Series 22 modular contactor range, this electromechanical device features a 110–120 V AC / 110 V DC control coil and a 3 normally open (NO) + 1 normally closed (NC) contact arrangement with a dedicated mirror-contact function.

Engineered for continuous-duty applications, the Finder 22.44.0.120.4717 combines substantial switching capacity with a compact DIN rail-mounted design. Its 40 A rated contact current, 176 A maximum peak current and AgSnO₂ contact material make it suitable for demanding electrical switching applications, including compatible lighting, heating and motor loads.

The contactor incorporates a low-noise AC/DC coil with integrated varistor protection, reinforced insulation between the coil and contacts, and a mechanical contact-position indicator. Its 3 NO + 1 NC mirror-contact configuration provides useful feedback for appropriately designed control and safety-monitoring circuits, while standard 35 mm DIN rail mounting simplifies installation in electrical distribution boards and industrial control panels.

Key Advantages

  • 40 A modular installation contactor for reliable electrical power switching.
  • 110–120 V AC / 110 V DC control coil for compatible AC and DC control supplies.
  • Four-pole configuration with 3 NO + 1 NC contacts for three-phase switching and contact-state feedback.
  • Mirror-contact design supports monitoring of the main power contacts.
  • 176 A maximum peak current for suitable high-inrush switching applications.
  • AgSnO₂ contacts provide durable switching performance.
  • Low-noise coil operation makes the contactor suitable for building services installations.
  • Integrated varistor protection helps limit switching transients from the operating coil.
  • Reinforced insulation separates the control circuit from the switched contacts.
  • Mechanical contact-position indicator assists with inspection and troubleshooting.
  • Continuous-duty design supports applications requiring prolonged energisation.
  • DIN rail mounting and screw terminals simplify installation and maintenance.

Key Features

  • Finder Series 22 modular installation contactor.
  • 40 A rated contact current.
  • 176 A maximum peak contact current.
  • 110–120 V AC, 50/60 Hz, or 110 V DC control supply.
  • Four-pole contact arrangement: 3 NO + 1 NC.
  • Mirror-contact version identified by the 4717 contact configuration.
  • 400 V AC rated contact voltage.
  • 480 V AC maximum switching voltage.
  • 26,000 VA rated AC-1 / AC-7a load capacity under specified conditions.
  • 22 A AC-3 / AC-7b rated current at 400 V AC.
  • 11 kW three-phase motor rating at 400–440 V AC.
  • 6 VA / 6 W nominal coil consumption.
  • Double-break contact construction with a contact gap of at least 3 mm.
  • AgSnO₂ silver tin oxide contacts.
  • Integrated coil varistor for transient suppression.
  • Mechanical contact-position indication.
  • 20 ms operate time and 45 ms release time.
  • IP20 protection rating.
  • 35 mm DIN rail mounting in accordance with EN 60715.

Mirror-Contact Monitoring and Reliable Three-Phase Switching

The Finder 22.44.0.120.4717 incorporates a 3 NO + 1 NC mirror-contact arrangement that provides three normally open power contacts and a normally closed monitoring contact. When the control coil is energised, the three normally open contacts close to supply the connected loads, while the normally closed contact opens. When the coil is de-energised, the contacts return to their normal positions.

The mirror-contact function is particularly valuable in applications requiring feedback about the state of the main contactor contacts. It provides a mechanically defined relationship between the normally open power contacts and the normally closed monitoring contact, supporting fault detection when used with an appropriately designed external monitoring or safety-control system. The contactor itself is not a standalone safety controller.

The 110–120 V AC / 110 V DC low-noise coil incorporates varistor protection to help reduce electrical transients during switching. Combined with reinforced insulation, double-break contacts and continuous-duty construction, these features support reliable operation in industrial automation, electrical distribution and building services applications.

Typical Applications

  • Industrial electrical distribution boards.
  • Commercial building electrical installations.
  • Three-phase power switching and control.
  • Motor control applications within specified utilisation ratings.
  • Building management and automation systems.
  • Electrical heating and ventilation control.
  • Commercial and industrial lighting systems.
  • Industrial machinery control panels.
  • Safety-related circuits requiring monitored contactor feedback.
  • Electrical load switching using 110–120 V AC control circuits.
  • Compatible automation systems using 110 V DC control supplies.
  • Power switching installations requiring three normally open contacts and one monitoring contact.

Technical Specifications

Tick the specs you need, then view products that match.

Terminal Type Screw
Poles 4-pole
Device Type Modular contactor
Coil Type AC, AC/DC, DC
Coil Voltage Range 100–130 V
Manufacturer Finder
Series 22 Series Modular Contactors
Type 22.44
Model 22.44.0.120.4717
Product type Modular installation contactor
Technology Electromechanical
Operating principle Monostable / non-latching
Number of poles 4
Contact configuration 3 NO + 1 NC
Normally open contacts 3
Normally closed contacts 1
Contact monitoring Mirror-contact configuration
Rated contact current 40 A
Maximum peak current 176 A
Rated contact voltage 400 V AC
Maximum switching voltage 480 V AC
Rated load AC-1 / AC-7a 26,000 VA under specified conditions
Rated current AC-3 / AC-7b at 400 V AC 22 A
Three-phase motor rating at 400–440 V AC 11 kW
Rated current AC-5a at 250 V AC 20 A
Nominal AC coil voltage 110–120 V AC
Nominal DC coil voltage 110 V DC
AC coil frequency 50/60 Hz
Nominal coil consumption 6 VA / 6 W
Coil operating range 85–110% of nominal voltage
Coil holding voltage 85% of nominal voltage
Specified drop-out voltage 20% of nominal voltage
Coil protection Integrated varistor
Coil operation Low-noise AC/DC design
Contact material Silver tin oxide (AgSnO₂)
Contact construction Double-break bridge contacts
Contact gap At least 3 mm
Operate time 20 ms
Release time 45 ms
Mechanical life 3,000,000 operations
Electrical life at rated AC-7a load 100,000 operations
Impulse withstand voltage between coil and contacts 6 kV
Insulation Reinforced insulation between coil and contacts
Maximum incandescent / halogen lamp load at 230 V AC 4000 W
Protection rating IP20
Mounting type 35 mm DIN rail (EN 60715)
Terminal type Screw terminals / box-clamp connections
Status indication Mechanical contact-position indicator
Operating duty Continuous duty for coil and contacts
Applicable standards EN 61095 and EN 60947-4-1
Mounting environment Electrical distribution boards and control cabinets

Frequently Asked Questions

What is the Finder 22.44.0.120.4717 used for?

The Finder 22.44.0.120.4717 is a four-pole modular installation contactor used for remote switching of electrical loads. It is suitable for industrial control panels, three-phase electrical systems, building automation and applications requiring contactor-state monitoring.

What is the current rating of the Finder 22.44.0.120.4717?

The contactor has a 40 A rated contact current and a 176 A maximum peak current. The permissible continuous and switching loads depend on the operating voltage, utilisation category, ambient conditions and connected equipment.

What control voltage does the Finder 22.44.0.120.4717 require?

The contactor is designed for a 110–120 V AC supply at 50/60 Hz or a compatible 110 V DC supply. The coil features low-noise operation and integrated varistor protection.

What contact configuration does the Finder 22.44.0.120.4717 have?

The contactor has four poles arranged as 3 normally open and 1 normally closed contacts (3 NO + 1 NC). The normally closed contact is part of the mirror-contact arrangement used for contactor-state monitoring.

What is the mirror-contact function on this Finder contactor?

The mirror-contact function provides a mechanically defined relationship between the main normally open power contacts and the normally closed monitoring contact. This supports contactor-state feedback and fault monitoring in appropriately designed external control systems.

Can the Finder 22.44.0.120.4717 switch three-phase loads?

Yes. Its three normally open power contacts can switch compatible three-phase loads. The contactor has a specified 11 kW three-phase motor rating at 400–440 V AC, subject to the applicable utilisation category and installation conditions.

Can the Finder 22.44.0.120.4717 be used with a 120 V AC control supply?

Yes. The contactor's nominal AC control voltage range includes 120 V AC at 50/60 Hz. It should be supplied within the manufacturer's specified coil operating limits.

Does the Finder 22.44.0.120.4717 have coil surge protection?

Yes. The contactor includes an integrated varistor protection circuit that helps suppress voltage transients generated when the coil is switched, supporting integration with compatible electrical control equipment.

Can this Finder contactor be installed on a DIN rail?

Yes. The Finder 22.44.0.120.4717 is designed for mounting onto a standard 35 mm DIN rail conforming to EN 60715. It uses screw terminal connections and is intended for installation inside a suitable electrical enclosure.

What is the difference between the Finder 22.44.0.120.4717 and 22.44.0.024.4717?

Both models belong to the Finder Series 22 and use a 40 A, 3 NO + 1 NC mirror-contact configuration. The principal difference is the control voltage: the 22.44.0.120.4717 uses a 110–120 V AC / 110 V DC coil, while the 22.44.0.024.4717 uses a 24 V AC/DC coil.

What is the protection rating of the Finder 22.44.0.120.4717?

The contactor has an IP20 protection rating and is intended for installation inside suitable electrical distribution boards or control cabinets that provide the environmental protection required for the application.

Trusted by Electrical Installers and Industrial Automation Professionals

Finder Series 22 modular contactors provide reliable power switching for commercial, industrial and building automation installations. The Finder 22.44.0.120.4717 combines a 40 A rated contact current, 110–120 V AC / 110 V DC low-noise control coil, 3 NO + 1 NC mirror-contact arrangement, integrated varistor protection and robust DIN rail construction for dependable electrical switching and monitored control applications.