1SBL351024R8100 ABB UA50-30-00RA 3 Pole Contactor 24V 50/60Hz Capacitor Switching Contactor

1SBL351024R8100 ABB UA50-30-00RA 3 Pole Contactor 24V 50/60Hz Capacitor Switching Contactor

ABB 1SBL351024R8100 UA50-30-00RA-81 is a 3-pole capacitor switching contactor rated at 40 kvar at 400 V AC-6b, featuring a 24 V AC 50/60 Hz coil and integrated damping resistors for limiting capacitor energisation current peaks.

SKU: 1SBL351024R8100Alt SKU: UA50-30-00RA 24V 50Hz / 24V 60HzMPN: 1SBL351024R8100
Price
List Price £411.17 ex VAT
Your Price (ex VAT) Save 35%
£267.26 35% OFF
You save £143.91 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £267.26
Trade pricing is personalised to your account

Manufacturer Lead Time

£267.26

Why Choose the ABB 1SBL351024R8100 UA50 Capacitor Switching Contactor?

The ABB 1SBL351024R8100, model UA50-30-00RA-81, is a specialised 3-pole capacitor switching contactor designed for reliable switching of capacitor banks in industrial power factor correction systems. As part of the ABB UA..RA contactor series, it is specifically engineered for installations where capacitor energisation can produce extremely high peak currents.

Unlike a conventional contactor, the UA50-30-00RA-81 is supplied with a special front-mounted block that inserts three damping resistors into the circuit during capacitor energisation. These resistors pre-charge the capacitors and limit the initial and secondary current peaks before the main contacts close, helping protect the contactor, capacitors and associated electrical equipment from excessive inrush current.

With a rated capacitor switching power of 40 kvar at 400 V AC under AC-6b, the UA50-30-00RA-81 is designed for demanding automatic power factor correction applications. Its AC-operated laminated magnet circuit uses a 24 V AC coil at 50/60 Hz, while the main circuit supports operational voltages up to 690 V AC.

Key Advantages

  • Specialised 3-pole contactor for capacitor bank switching.
  • 40 kvar rated operational power at 400 V AC under AC-6b utilisation.
  • Suitable for installations where capacitor switching peak current can greatly exceed the nominal RMS current.
  • Integrated three-resistor damping system limits capacitor energisation current peaks.
  • 24 V AC 50/60 Hz electromagnetic control coil for low-voltage control circuits.
  • Designed for capacitor switching without the need for additional external limiting inductances.

Key Features

  • ABB UA50-30-00RA capacitor switching contactor.
  • 3 normally open main power contacts.
  • 40 kvar capacitor switching rating at 400 V AC under IEC AC-6b.
  • 50 kvar operational power rating at 480 V under UL/CSA conditions.
  • 24 V AC control voltage at 50/60 Hz.
  • Special front-mounted block with three damping resistors.
  • Capacitor pre-charging helps limit the second current peak as the main contacts close.
  • 690 V AC maximum main circuit operational voltage.
  • AC-operated laminated magnet circuit.
  • Screw terminal connections and block-type construction.

Reliable Capacitor Switching for Power Factor Correction

Capacitor banks can draw extremely high transient currents when energised, particularly where one capacitor bank is switched onto a supply containing capacitors that are already energised. These current peaks can cause premature wear or welding of conventional contactor contacts and place significant electrical stress on the capacitors and associated switchgear.

The UA50-30-00RA-81 addresses this challenge by inserting three damping resistors into the circuit before the main contacts close. This arrangement limits the initial current peak and pre-charges the capacitor to reduce the subsequent current peak, providing controlled and dependable switching for automatic power factor correction systems.

Typical Applications

  • Automatic power factor correction panels.
  • Industrial capacitor bank switching.
  • Reactive power compensation systems.
  • Electrical distribution switchboards.
  • Industrial plants with inductive motor loads.
  • Commercial and industrial power quality systems.

Technical Specifications

Tick the specs you need, then view products that match.

Terminal Type Screw
Poles 3-pole
Coil Voltage Range 24 V
Device Type Capacitor Switching Contactor
Auxiliary Contacts None
Coil Type AC
Manufacturer ABB
Series UA..RA
Model UA50-30-00RA-81
Product ID 1SBL351024R8100
EAN / GTIN 3471522303813
Product type Capacitor switching contactor
Main contacts 3 NO
Auxiliary contacts fitted 0 NO + 0 NC
Rated operational power (AC-6b, 400 V) 40 kvar
UL / CSA rated operational power (480 V) 50 kvar
Main circuit operational voltage up to 690 V AC
Control voltage at 50 Hz 24 V AC
Control voltage at 60 Hz 24 V AC
Control circuit AC operated
Magnet circuit Laminated
Inrush current limiting 3 integrated damping resistors
Terminal type Screw terminals
Electrical durability below 500 V 250,000 operating cycles
Electrical durability from 500–690 V 100,000 operating cycles
Ambient operating temperature -40 to +70 °C
Storage temperature -60 to +80 °C
Dimensions (H × W × D) approx. 150 × 70 × 140.4 mm
Weight approx. 1.35 kg

Frequently Asked Questions

What is the ABB 1SBL351024R8100 used for?

The ABB 1SBL351024R8100 is a specialised capacitor switching contactor used for controlling capacitor banks in automatic power factor correction and reactive power compensation systems.

What capacitor bank size can the UA50-30-00RA-81 switch?

The contactor has an IEC rated operational power of 40 kvar at 400 V AC under AC-6b utilisation conditions.

What control voltage does the ABB UA50-30-00RA-81 require?

The UA50-30-00RA-81 uses an AC-operated electromagnetic coil rated at 24 V AC at 50/60 Hz.

How does the UA50-30-00RA-81 limit capacitor inrush current?

The contactor incorporates a special front-mounted block containing three damping resistors. These resistors are inserted during energisation to pre-charge the capacitor and limit high current peaks before the main contacts close.

Does the UA50-30-00RA-81 require additional limiting inductances?

No. The UA..RA contactor is supplied complete with its damping resistors and is designed to be used without additional external limiting inductances for the specified capacitor switching applications.

Designed for Reliable Industrial Power Factor Correction

ABB UA..RA capacitor switching contactors provide controlled switching of capacitor banks by combining robust three-pole contactor construction with integrated damping resistors that limit damaging energisation current peaks in industrial power factor correction systems.