1SBK134137R1300 ABB DRAF09-13N 100-250V50/60HZ Contactor Starter Enclosed Direct-On-Line Starter 3 Pole 1NO Auxiliary Contact

1SBK134137R1300 ABB DRAF09-13N 100-250V50/60HZ Contactor Starter Enclosed Direct-On-Line Starter 3 Pole 1NO Auxiliary Contact

ABB DRAF09-13N 1SBK134137R1300 is an IP66 enclosed direct-on-line starter rated at 9 A at 400 V for three-phase motors, with a 100–250 V AC 50/60 Hz control supply and support for motors up to 4 kW at 380–400 V.

SKU: 1SBK134137R1300Alt SKU: DRAF09-13N 100-250V50/60HZMPN: 1SBK134137R1300
Price
List Price £86.39 ex VAT
Your Price (ex VAT) Save 35%
£56.15 35% OFF
You save £30.24 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £56.15
Trade pricing is personalised to your account

Manufacturer Lead Time

£56.15

Why Choose the ABB DRAF09-13N Enclosed Direct-On-Line Starter?

The ABB DRAF09-13N, order code 1SBK134137R1300, is an enclosed direct-on-line (DOL) motor starter designed for switching and controlling three-phase AC motors. Combining an ABB AF contactor with a robust enclosure, the DRAF09-13N provides a practical motor-control solution for machinery, pumps, fans and other industrial equipment.

The DRAF09-13N is rated for a maximum operational current of 9 A at 400 V and supports three-phase motors rated up to 2.2 kW at 220–240 V, 4 kW at 380–400 V and 5.5 kW at 500–690 V. Its AF contactor uses electronic coil technology with a wide 100–250 V AC 50/60 Hz control voltage range.

Designed as an enclosed starter, the DRAF09-13N provides IP66 protection for demanding installation environments. A compatible ABB TF42 thermal overload relay can be selected separately to provide motor overload protection, allowing the starter to be configured to suit the connected motor's rated current.

Key Advantages

  • Enclosed direct-on-line starter for three-phase AC motors.
  • 9 A maximum operational current at 400 V.
  • Supports motors up to 4 kW at 380–400 V.
  • Wide 100–250 V AC 50/60 Hz control voltage range.
  • IP66 enclosure protection for demanding industrial installations.
  • Compatible with ABB TF42 thermal overload relays, selected separately to suit the motor.

Key Features

  • ABB DRAF enclosed direct-on-line starter range.
  • 9 A maximum operational current at 400 V.
  • 2.2 kW motor rating at 220–240 V.
  • 4 kW motor rating at 380–400 V.
  • 5.5 kW motor rating at 500–690 V.
  • 100–250 V AC 50/60 Hz control voltage.
  • ABB AF contactor technology for reliable motor switching.
  • Enclosed design with IP66 ingress protection.

Reliable Direct-On-Line Motor Control

Direct-on-line starters such as the ABB DRAF09-13N switch the full supply voltage directly to a three-phase motor when starting. This straightforward motor-control method is widely used where the electrical supply and driven equipment can accommodate the motor's direct starting current and torque.

The DRAF09-13N combines ABB AF contactor technology with a protective enclosure to simplify the implementation of an enclosed motor starter. When paired with a correctly selected TF42 thermal overload relay, it provides a compact solution for motor switching and overload protection in industrial machinery and process equipment.

Typical Applications

  • Industrial pumps and pumping systems.
  • Fans and ventilation equipment.
  • Conveyors and material handling machinery.
  • Compressors and process equipment.
  • Industrial machinery and production equipment.
  • OEM motor-control installations.

Technical Specifications

Tick the specs you need, then view products that match.

Poles 3-pole
Coil Voltage Range 100–130 V, 200–250 V
Coil / Supply Voltage 110 V AC, 115 V AC, 120 V AC, 208 V AC, 220 V AC, 230 V AC, 240 V AC
Device Type Accessory
Coil Type AC
Manufacturer ABB
Series DRAF
Model DRAF09-13N
Order code 1SBK134137R1300
Product type Enclosed direct-on-line motor starter
Motor phases 3-phase
Maximum operational current at 400 V 9 A
Motor power at 220–240 V 2.2 kW
Motor power at 380–400 V 4 kW
Motor power at 500 V 5.5 kW
Motor power at 690 V 5.5 kW
Control voltage 100–250 V AC, 50/60 Hz
Control supply wiring Phase / neutral
Protection rating IP66
Compatible overload relay ABB TF42 series, ordered separately
Dimensions (H × W × D) 230 × 126.5 × 131.5 mm
Weight 0.820 kg

Frequently Asked Questions

What is the ABB DRAF09-13N used for?

The DRAF09-13N is an enclosed direct-on-line starter designed for switching and controlling three-phase AC motors in industrial equipment.

What motor power can the ABB DRAF09-13N control?

The DRAF09-13N supports motors rated up to 2.2 kW at 220–240 V, 4 kW at 380–400 V and 5.5 kW at 500–690 V.

What control voltage does the DRAF09-13N require?

The DRAF09-13N uses a 100–250 V AC 50/60 Hz control supply with phase-to-neutral control wiring.

What is the protection rating of the ABB DRAF09-13N?

The DRAF09-13N has an IP66 protection rating, providing a high level of protection against dust and water ingress.

Does the ABB DRAF09-13N include a thermal overload relay?

No. A compatible ABB TF42 thermal overload relay is ordered separately and should be selected according to the rated current of the connected motor.

Trusted ABB Motor Control Technology

ABB DRAF enclosed direct-on-line starters combine proven AF contactor technology, wide-range electronic coil control and robust enclosure protection to provide dependable motor switching for industrial machinery and equipment.