ABB CM-MPN.52S 1SVR750487R8300 is a multifunctional three-phase monitoring relay for 350–580 V AC systems with TRMS measurement, phase failure, phase sequence, overvoltage, undervoltage and phase unbalance monitoring, configurable changeover outputs and screw terminals.
£213.04
The ABB CM-MPN.52S, order code 1SVR750487R8300, is a multifunctional three-phase monitoring relay designed to supervise critical phase and voltage conditions in industrial three-phase electrical systems. As part of the ABB CM-MPN three-phase monitoring relay series, it monitors phase failure, phase sequence, overvoltage, undervoltage and phase unbalance to help protect motors, machinery and automation equipment.
The CM-MPN.52S operates directly from the monitored circuit with a 3 × 350–580 V AC line-to-line rated control supply and measuring voltage. It uses the TRMS measuring principle, while adjustable thresholds for overvoltage, undervoltage and phase unbalance allow the monitoring characteristics to be matched to the installation. Phase sequence monitoring can be switched off, and automatic phase sequence correction is configurable.
With two configurable changeover (SPDT) output contacts, a 200 ms start-up delay and an adjustable tripping delay of 0 or 0.1–30 s, the CM-MPN.52S provides flexible signalling and control. Its screw connection technology, 45 mm housing and DIN-rail mounting make it suitable for robust integration into industrial control panels.
Three-phase monitoring relays continuously supervise incoming electrical supplies and provide a switching response when monitored parameters move outside configured limits. The ABB CM-MPN.52S monitors voltage levels, phase presence, phase sequence and phase balance, helping protect three-phase motors, machinery and automation equipment against potentially damaging supply conditions.
The 350–580 V AC line-to-line range makes the CM-MPN.52S suitable for a broad range of industrial three-phase systems. Configurable output operation allows the relay contacts to provide a common signal or separate signals, while adjustable thresholds and timing functions enable the response to be matched to the requirements of the installation.
Tick the specs you need, then view products that match.
| Time Delay | Adjustable | |
|---|---|---|
| Monitoring Function | Three-phase supply | |
| Monitored Supply | Three-phase | |
| Signal / Input Range | 3 × 350–580 V AC | |
| Series | CM-MPN | |
| ABB order code | 1SVR750487R8300 | |
| Product group | 310921 – Measuring & Monitoring Relays | |
| Product type | Multifunctional three-phase monitoring relay | |
| Rated control supply voltage | 3 × 350–580 V AC line-to-line | |
| Measuring voltage | 3 × 350–580 V AC line-to-line | |
| Rated frequency | 50 / 60 Hz | |
| Supply source | Powered by measuring circuit | |
| Measuring principle | TRMS | |
| Phase failure monitoring | Yes | |
| Phase sequence monitoring | Yes, selectable | |
| Automatic phase sequence correction | Configurable | |
| Overvoltage monitoring | Yes | |
| Undervoltage monitoring | Yes | |
| Phase unbalance monitoring | Yes | |
| Start-up delay | 200 ms | |
| Tripping delay | 0 s or adjustable 0.1–30 s | |
| Tripping function | ON- or OFF-delay, selectable | |
| Output | 2 × 1 c/o or 1 × 2 c/o (SPDT) contacts, configurable | |
| Contact rating | 250 V / 4 A | |
| Connection technology | Screw terminals | |
| Housing protection | IP50 | |
| Operating temperature | -25 to +60 °C | |
| Storage temperature | -40 to +85 °C | |
| Mounting type | DIN rail | |
| Width | 45 mm | |
| Height | 85.6 mm | |
| Depth | 104.8 mm | |
| Net weight | approx. 0.23 kg |
The CM-MPN.52S monitors three-phase electrical supplies for phase failure, phase sequence, overvoltage, undervoltage and phase unbalance conditions.
The CM-MPN.52S operates with a three-phase line-to-line rated control supply and measuring voltage of 350–580 V AC.
Yes. Phase sequence monitoring is selectable, and the relay also provides configurable automatic phase sequence correction.
The relay provides a 200 ms start-up delay and a tripping delay that can be switched off for instantaneous operation or adjusted from 0.1–30 s, with selectable ON- or OFF-delay behaviour.
The CM-MPN.52S uses screw terminals and provides two configurable changeover contacts that can operate as 2 × 1 c/o or 1 × 2 c/o outputs.
ABB CM three-phase monitoring relays provide dependable supervision of voltage and phase conditions in industrial electrical systems, helping protect motors, machinery and automation equipment against abnormal three-phase supply conditions.