1SVR730720R1400 ABB CM-MSS.11S Thermistor Motor Protection Relay 24–240 V AC/DC

1SVR730720R1400 ABB CM-MSS.11S Thermistor Motor Protection Relay 24–240 V AC/DC

ABB CM-MSS.11S 1SVR730720R1400 is a 24–240 V AC/DC thermistor motor protection relay with one PTC sensor circuit, 1 N/O + 1 N/C output contacts, dynamic interrupted-wire detection, non-volatile fault storage and automatic reset.

SKU: 1SVR730720R1400Alt SKU: CM-MSS.11SMPN: 1SVR730720R1400
Price
List Price £120.63 ex VAT
Your Price (ex VAT) Save 35%
£78.41 35% OFF
You save £42.22 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £78.41
Trade pricing is personalised to your account

Manufacturer Lead Time

£78.41

Why Choose the ABB CM-MSS.11S Thermistor Motor Protection Relay?

The ABB CM-MSS.11S 1SVR730720R1400 is a compact thermistor motor protection relay designed to monitor PTC temperature sensors embedded in electric motor windings. As part of the ABB CM-MSS range, it helps protect motors against excessive winding temperature caused by conditions such as overload, heavy starting duty or insufficient cooling.

The CM-MSS.11S provides one PTC sensor circuit with dynamic interrupted-wire detection, helping supervise both motor temperature and the integrity of the connected sensor circuit. It also incorporates non-volatile fault storage and automatically resets after the fault condition has been removed.

A wide 24–240 V AC/DC control supply simplifies integration across industrial control systems. The relay provides one normally open and one normally closed output contact, rated at up to 250 V / 4 A, and features ATEX approval, screw-terminal connection technology and a slim DIN-rail housing.

Key Advantages

  • Dedicated PTC thermistor motor protection for temperature supervision.
  • Wide 24–240 V AC/DC control supply for flexible integration.
  • One PTC sensor circuit for motor winding temperature monitoring.
  • Dynamic interrupted-wire detection supervises sensor circuit continuity.
  • Non-volatile fault storage retains fault information.
  • Automatic reset after the monitored fault has been removed.
  • 1 N/O + 1 N/C output contacts support control and signalling functions.
  • ATEX approved for applicable motor protection applications.
  • Screw-terminal version for straightforward industrial panel wiring.

Key Features

  • ABB CM-MSS.11S thermistor motor protection relay.
  • 1 PTC sensor circuit.
  • 24–240 V AC/DC rated control supply voltage.
  • 1 normally open + 1 normally closed output contact.
  • Output contacts rated at up to 250 V / 4 A.
  • Dynamic interrupted-wire monitoring.
  • Non-volatile fault storage.
  • Automatic reset.
  • Closed-circuit operating principle.
  • ATEX approved.
  • Screw connection technology with double-chamber cage terminals.
  • DIN-rail mounting for industrial control cabinets.

Reliable PTC Thermistor Motor Protection

PTC thermistors embedded in motor windings respond directly to winding temperature, with their resistance increasing sharply when the specified response temperature is reached. The ABB CM-MSS.11S continuously monitors the connected PTC sensor circuit and changes its output state when an excessive temperature condition occurs, allowing the associated motor-control circuit to initiate a protective response.

The relay's dynamic interrupted-wire detection additionally supervises the sensor circuit for wiring interruption. Combined with non-volatile fault storage, automatic reset and a wide 24–240 V AC/DC supply range, this provides a practical motor temperature monitoring solution for industrial machinery and automated equipment.

Typical Applications

  • PTC-equipped electric motor thermal protection.
  • Motor winding temperature monitoring.
  • Pumps, fans and ventilation equipment.
  • Compressors and refrigeration machinery.
  • Conveyors and material handling equipment.
  • Industrial production and process machinery.
  • Motor control centres and electrical control panels.
  • OEM machinery and industrial automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Reset Type Automatic
Monitoring Function Temperature / thermistor
Series CM-MSS
ABB order code 1SVR730720R1400
Product type Thermistor motor protection relay
Sensor type PTC thermistor
Number of sensor circuits 1
Rated control supply voltage 24–240 V AC/DC
Output 1 N/O + 1 N/C contact
Contact rating 250 V / 4 A
Reset function Automatic reset
Interrupted-wire monitoring Dynamic
Fault storage Non-volatile
Operating principle Closed-circuit principle
ATEX approval Yes
Terminal type Screw terminals
Operating temperature -25 to +60 °C
Storage temperature -40 to +85 °C
UL/CSA maximum output circuit operating voltage 300 V AC
UL/CSA contact rating B300
Net weight approx. 0.127 kg

Frequently Asked Questions

What is the ABB CM-MSS.11S 1SVR730720R1400 used for?

It is a thermistor motor protection relay used to monitor PTC temperature sensors and help protect electric motors against excessive winding temperature.

What control supply does the CM-MSS.11S require?

The CM-MSS.11S operates from a wide 24–240 V AC/DC rated control supply.

What outputs does the ABB CM-MSS.11S provide?

The relay provides one normally open and one normally closed contact, with contacts rated at up to 250 V / 4 A.

Does the CM-MSS.11S monitor the PTC sensor wiring?

Yes. The CM-MSS.11S provides dynamic interrupted-wire detection to supervise the integrity of its single PTC sensor circuit.

How does the CM-MSS.11S reset after a fault?

The CM-MSS.11S provides automatic reset after the fault condition has been removed and also incorporates non-volatile fault storage.

Trusted ABB Motor Protection Technology

ABB CM-MSS thermistor motor protection relays provide dependable PTC temperature and sensor-circuit supervision for industrial motors, helping machine builders, panel builders and operators protect critical equipment against excessive thermal stress.