CPTDINAV63LDBAX - Advanced Power Tranducer

CPTDINAV63LDBAX – Advanced Power Tranducer

Carlo Gavazzi CPTDINAV63LDBAX advanced DIN rail power transducer for 120 / 208 V L-L, 1 / 5 A AC two-phase and three-phase unbalanced load monitoring with 18-60 V AC/DC auxiliary supply.

SKU: CPTDINAV63LDBAXMPN: CPTDINAV63LDBAX
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Carlo Gavazzi CPTDINAV63LDBAX Advanced Power Transducer?

The Carlo Gavazzi CPTDINAV63LDBAX is a compact and reliable DIN rail advanced power transducer designed for monitoring electrical parameters in industrial power systems, energy management installations and automation panels. As part of the Carlo Gavazzi CPT-DIN advanced power transducer range, it provides accurate measurement and communication of key electrical values in two-phase and three-phase unbalanced load applications.

This power transducer is designed for panel builders, system integrators and facilities engineers who require dependable electrical monitoring in a space-saving DIN rail format. It supports measurement of voltage, current, power, power factor, frequency and energy values, helping operators understand system performance and improve electrical efficiency.

With a 120 / 208 V L-L voltage input, 1 / 5 A AC current input and a low-voltage 18–60 V AC/DC auxiliary supply, the CPTDINAV63LDBAX is well suited to industrial panels, switchboards and distributed monitoring systems where compact power measurement and communication are required.

Key Advantages

  • Compact advanced power transducer for DIN rail mounting.
  • Designed for two-phase and three-phase unbalanced load monitoring.
  • 120 / 208 V L-L voltage input for low-voltage monitoring applications.
  • 1 / 5 A AC current input suitable for CT-connected systems.
  • 18–60 V AC/DC auxiliary supply for control panel integration.
  • Supports power and energy monitoring in industrial automation systems.

Key Features

  • Carlo Gavazzi CPT-DIN advanced power transducer.
  • DIN rail mounted enclosure for panel installation.
  • Two-phase and three-phase unbalanced load measurement.
  • 120 / 208 V L-L voltage measurement range.
  • 1 / 5 A AC current input.
  • 18–60 V AC/DC power supply.
  • Measures electrical variables including voltage, current, power, frequency, energy and power factor.
  • Suitable for energy management, supervision and industrial monitoring systems.

Advanced Power Monitoring for Industrial Panels

Power transducers such as the Carlo Gavazzi CPTDINAV63LDBAX convert electrical measurements into usable monitoring information for automation, metering and energy supervision systems. By measuring power consumption and system behaviour, they help engineers identify load conditions, improve efficiency and support reliable electrical distribution.

The CPT-DIN advanced series is suited to installations where compact DIN rail equipment is preferred and where reliable monitoring of unbalanced electrical loads is required. Its low-voltage auxiliary supply and panel-friendly design make it a practical choice for industrial control cabinets, machine panels and building services systems.

Typical Applications

  • Industrial electrical panels and switchboards.
  • Energy monitoring and power management systems.
  • Two-phase and three-phase unbalanced load monitoring.
  • Automation cabinets and control systems.
  • Machine power consumption monitoring.
  • Facilities management and building services monitoring.

Technical Specifications

Tick the specs you need, then view products that match.

Measurement Connection Type CT connection
Current Input Rating (A) 5 A
Device Type Power transducer
Measurement Functions Current, Energy, Frequency, Power, Power factor, Voltage
Phase Three Phase
Signal / Input Range AC V / A (TRMS)
Coil / Supply Voltage 18–60 V AC/DC
Manufacturer Carlo Gavazzi
Series CPT-DIN Advanced
Model CPTDINAV63LDBAX
Product type Advanced power transducer
Mounting type DIN rail mounting
Measured system 2-phase / 3-phase unbalanced load
Voltage input 120 / 208 V L-L
Current input 1 / 5 A AC
Auxiliary supply 18–60 V AC/DC
Measurement functions Voltage, current, frequency, power, energy and power factor
Application Power monitoring and energy management
Installation type Control panel / switchboard mounting
Protection rating IP20
Configuration Advanced compact transducer format
Typical connection CT-connected electrical monitoring system

Frequently Asked Questions

What is the Carlo Gavazzi CPTDINAV63LDBAX used for?

The CPTDINAV63LDBAX is used to monitor electrical values such as voltage, current, power, frequency, energy and power factor in two-phase and three-phase unbalanced load systems.

What voltage input does this power transducer support?

This model is designed for a 120 / 208 V L-L voltage input.

What current input is used with the CPTDINAV63LDBAX?

The transducer supports 1 / 5 A AC current input, making it suitable for CT-connected power monitoring applications.

What auxiliary supply does the CPTDINAV63LDBAX require?

The CPTDINAV63LDBAX operates from an 18–60 V AC/DC auxiliary supply.

Is this model suitable for DIN rail installation?

Yes, the CPTDINAV63LDBAX is designed for DIN rail mounting inside control panels, automation cabinets and electrical switchboards.

Trusted by Industrial Automation Engineers Worldwide

Carlo Gavazzi CPT-DIN power transducers are widely used by panel builders, automation engineers and energy management specialists for compact power monitoring, electrical measurement and integration into industrial control systems.