CPTDINAV61HA3AX - Advanced Power Transducer

CPTDINAV61HA3AX – Advanced Power Transducer

Carlo Gavazzi CPTDINAV61HA3AX advanced power transducer with 57–120 V L-N and 100–208 V L-L voltage inputs, 5 A current transformer inputs and three 20 mA DC analogue outputs for industrial energy monitoring and automation systems.

SKU: CPTDINAV61HA3AXMPN: CPTDINAV61HA3AX
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Carlo Gavazzi CPTDINAV61HA3AX Advanced Power Transducer?

The Carlo Gavazzi CPTDINAV61HA3AX is a compact and versatile three-phase advanced power transducer designed for accurate electrical measurement and conversion in industrial energy monitoring, automation and control systems. As part of the Carlo Gavazzi CPTDIN series, it combines current and voltage measurement with analogue signal outputs for straightforward integration with PLCs, controllers, data acquisition equipment and building management systems.

The CPTDINAV61HA3AX measures electrical parameters in single-phase and three-phase systems and converts measured values into standard analogue signals for external monitoring and control equipment. Its 5 A current transformer inputs make it suitable for use with standard external CTs, while its three 20 mA DC analogue outputs allow multiple measured variables to be transmitted simultaneously.

Designed for systems with 57–120 V L-N and 100–208 V L-L voltage inputs, the CPTDINAV61HA3AX supports a nominal current input of 5 A, with a maximum of 6 A. A wide 90–260 V AC/DC auxiliary supply, 50/60 Hz operation and DIN rail mounting make the unit well suited to industrial switchboards, control cabinets and energy management installations.

Key Advantages

  • Advanced three-phase power transducer for industrial energy monitoring.
  • 57–120 V L-N and 100–208 V L-L voltage measurement range.
  • 5 A nominal current transformer inputs for standard CT-based measurement systems.
  • Three 20 mA DC analogue outputs for connection to monitoring and control equipment.
  • Wide 90–260 V AC/DC auxiliary power supply simplifies integration into industrial installations.
  • Supports measurement of both energy consumption and generation.
  • Compact DIN rail mounting saves valuable control-panel space.

Key Features

  • Carlo Gavazzi CPTDIN advanced transducer series.
  • Three-phase electrical energy transducer.
  • 57–120 V L-N input voltage range.
  • 100–208 V L-L input voltage range.
  • 5 A nominal and 6 A maximum current input.
  • Three analogue 20 mA DC outputs.
  • 90–260 V AC/DC auxiliary supply.
  • 50/60 Hz operating frequency.
  • Measurement of energy consumption and generation.
  • IP20 protection rating.
  • Compact enclosure for DIN rail mounting.

Accurate Power Monitoring for Industrial Automation

Power transducers such as the Carlo Gavazzi CPTDINAV61HA3AX convert electrical measurements into standardised analogue signals that can be used by PLCs, monitoring systems and other automation equipment. This enables important electrical parameters to be incorporated into centralised control, energy management and process monitoring systems without requiring operators to rely solely on local instrumentation.

The CPTDIN series is designed for compact installation in electrical panels and switchboards. With current transformer inputs, multiple analogue outputs and a wide-range auxiliary supply, the CPTDINAV61HA3AX provides a flexible interface between electrical distribution systems and industrial control equipment while supporting both energy consumption and generation monitoring.

Typical Applications

  • Industrial energy monitoring and management systems.
  • Electrical switchboards and distribution panels.
  • PLC and industrial automation systems.
  • Building management and energy management systems.
  • Machine and production-line power monitoring.
  • Generator and energy generation monitoring.
  • Process control and data acquisition systems.
  • OEM control panels and industrial machinery.

Technical Specifications

Tick the specs you need, then view products that match.

Coil / Supply Voltage 90–260 V AC/DC
Device Type Power transducer
Phase Single Phase
Analogue Output Signal 3 × 0/4–20 mA
Manufacturer Carlo Gavazzi
Series CPTDIN
Model CPTDINAV61HA3AX
Product type Advanced power transducer
Electrical system Single-phase / three-phase
Voltage input L-N 57–120 V AC
Voltage input L-L 100–208 V AC
Nominal current input 5 A
Maximum current input 6 A
Current input type 5 A current transformers
Frequency 50 / 60 Hz
Analogue outputs 3 × 20 mA DC
Auxiliary supply 90–260 V AC/DC
Energy metering Consumption and generation
Protection rating IP20
Mounting type DIN rail mounting
Dimensions (H × W × D) approx. 83.5 × 45 × 98.5 mm
EAN 8030956032383

Frequently Asked Questions

What is the Carlo Gavazzi CPTDINAV61HA3AX used for?

The CPTDINAV61HA3AX is an advanced power transducer used to measure electrical parameters and provide analogue output signals for industrial energy monitoring, automation and control systems.

What voltage range does the CPTDINAV61HA3AX support?

The transducer supports voltage inputs of 57–120 V L-N and 100–208 V L-L.

What current input does the CPTDINAV61HA3AX use?

The CPTDINAV61HA3AX is designed for 5 A current transformer inputs and supports a maximum input current of 6 A.

What outputs are provided by the CPTDINAV61HA3AX?

The CPTDINAV61HA3AX provides three 20 mA DC analogue outputs for transmitting measured electrical parameters to compatible monitoring and control equipment.

How is the CPTDINAV61HA3AX installed?

The transducer is designed for DIN rail mounting inside electrical control panels, switchboards and industrial automation cabinets.

Trusted Industrial Energy Measurement

Carlo Gavazzi CPTDIN power transducers provide industrial automation engineers, panel builders and energy management specialists with compact and flexible electrical measurement solutions for integrating power and energy data into modern monitoring and control systems.