CPTDINAV51HV3AX - Advanced Power Transducer

CPTDINAV51HV3AX – Advanced Power Transducer

Carlo Gavazzi CPTDINAV51HV3AX DIN rail energy transducer for three-phase electrical monitoring, with 230 to 347 V L-N, 400 to 600 V L-L, 5(6) A CT input and 3 x 0-10 V DC analogue outputs.

SKU: CPTDINAV51HV3AXMPN: CPTDINAV51HV3AX
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Carlo Gavazzi CPTDINAV51HV3AX Energy Transducer?

The Carlo Gavazzi CPTDINAV51HV3AX is a compact and advanced DIN rail energy transducer designed for accurate monitoring of three-phase electrical systems. As part of the Carlo Gavazzi CPTDIN Advanced range, it measures key electrical parameters and provides 3 analogue 0–10 V DC outputs for connection to PLCs, controllers and monitoring systems.

This transducer is ideal for industrial control panels, distribution boards and energy management applications where reliable electrical measurement is required without a local display. It supports standard 5 A current transformer inputs and is suitable for low voltage installations requiring continuous measurement of power, energy and operating conditions.

With voltage measurement ranges from 230 to 347 V L-N and 400 to 600 V L-L, support for 50/60 Hz operation and a wide 90 to 260 V AC/DC auxiliary supply, the CPTDINAV51HV3AX provides a practical multi-output analogue solution for industrial power monitoring applications.

Key Advantages

  • Compact DIN rail energy transducer for industrial monitoring.
  • Designed for three-phase electrical systems.
  • 5 A current transformer input for standard CT-based measurement.
  • 3 analogue outputs 0–10 V DC for control and monitoring equipment.
  • Suitable for monitoring both energy consumption and generation.
  • Ideal for PLC, process control and energy management integration.

Key Features

  • Carlo Gavazzi CPTDIN Advanced energy transducer.
  • DIN rail mounting for control cabinet installation.
  • Three-phase monitoring for industrial low voltage systems.
  • 230 to 347 V L-N and 400 to 600 V L-L voltage range.
  • 5(6) A current transformer input.
  • 3 x 0–10 V DC analogue outputs.
  • Measures voltage, current, frequency, power, energy and power factor.
  • Designed for industrial automation and energy monitoring applications.

Reliable Power Monitoring with Multiple Analogue Outputs

Energy transducers such as the Carlo Gavazzi CPTDINAV51HV3AX convert measured electrical parameters into standard analogue signals that can be used by automation and energy monitoring systems. This allows engineers to monitor load, demand, energy usage and operating conditions through PLCs, controllers or data acquisition equipment.

The CPTDINAV51HV3AX is designed for DIN rail installation and can be integrated into low voltage electrical panels for machine monitoring, distribution board measurement and energy management. Its CT-based current input and 3 x 0–10 V DC analogue outputs make it suitable for industrial systems requiring multiple simultaneous output signals.

Typical Applications

  • Industrial electrical control panels.
  • Three-phase machine monitoring.
  • Low voltage distribution boards.
  • Energy management systems.
  • PLC and process control integration.
  • Industrial power and operating hour monitoring.

Technical Specifications

Tick the specs you need, then view products that match.

Measurement Connection Type CT connection
MID Approval No
Device Type Power transducer
Current Input Rating (A) 5 A (CT)
Manufacturer Carlo Gavazzi
Series CPTDIN Advanced
Model CPTDINAV51HV3AX
Product type Energy transducer / power transducer
Mounting type DIN rail mounting
Rated voltage range 230 to 347 V L-N / 400 to 600 V L-L
Voltage inputs Three-phase network configurations
Current input 5(6) A via current transformers
Frequency 50 / 60 Hz
Analogue outputs 3 x 0–10 V DC
Energy metering Consumption and generation
Measured variables V, A, Hz, W, VA, var, PF, kWh, kvarh and operating hours
Auxiliary supply 90 to 260 V AC/DC
Display None
Protection rating IP20
Approvals CE / cURus / CSA

Frequently Asked Questions

What is the Carlo Gavazzi CPTDINAV51HV3AX used for?

The CPTDINAV51HV3AX is used to measure electrical variables in three-phase systems and provide 3 x 0–10 V DC analogue outputs for remote monitoring and control.

What output signals does it provide?

The transducer provides 3 analogue outputs rated at 0–10 V DC for connection to compatible PLCs, controllers and monitoring equipment.

What current input does this transducer require?

It is designed for use with standard 5(6) A current transformers.

Does the CPTDINAV51HV3AX have a display?

No. This model is supplied without a local display and is intended for remote monitoring through its analogue outputs.

Can it monitor both imported and generated energy?

Yes. The CPTDINAV51HV3AX supports energy metering for both consumption and generation.

Trusted by Energy Monitoring Professionals Worldwide

Carlo Gavazzi energy transducers are widely used by automation engineers, panel builders and energy management specialists for reliable electrical monitoring, compact DIN rail installation and dependable analogue signal output.