Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Lovato DMK00R1 single-phase True RMS digital voltmeter with a 15 to 660 V AC operating range, minimum and maximum voltage memory and programmable relay output for control and protection functions.
£132.33
The Lovato DMK00R1 is a compact single-phase digital voltmeter designed for accurate AC voltage monitoring, control and protection within industrial switchboards, machinery panels and electrical distribution systems. It combines clear digital indication with programmable relay functionality, allowing the instrument to monitor voltage conditions and operate external control or alarm circuits.
The meter measures voltage using the True RMS method, helping maintain dependable accuracy when electrical waveforms are distorted by variable speed drives, switched-mode power supplies or other non-linear loads. Its broad direct operating range of 15 to 660 V AC makes it suitable for many low-voltage applications, while programmable voltage transformer scaling supports indirect measurement on higher-voltage systems.
Unlike the standard DMK00, the DMK00R1 includes a programmable relay output for control and protection functions. This enables the meter to signal abnormal voltage conditions or control connected equipment according to configured thresholds. Its 96 × 48 mm flush-mounted housing, removable terminals and IP54 front protection make it well suited to professional panel-building applications.
Digital panel voltmeters provide continuous indication of the electrical supply, helping operators identify abnormal voltage levels, supply instability and developing installation faults. The DMK00R1 also stores minimum and maximum readings, allowing maintenance personnel to review voltage variations that may occur between inspections.
Its programmable relay output extends the instrument beyond basic indication. The relay can be configured to operate external alarms, contactors or control circuits when monitored voltage reaches defined conditions, making the DMK00R1 suitable for undervoltage, overvoltage and general voltage supervision applications.
Tick the specs you need, then view products that match.
| Measurement Functions | Voltage | |
|---|---|---|
| Phase | Single Phase | |
| Cut-Out Size (mm) | 92 × 45 mm | |
| Signal / Input Range | Frequency | |
| Coil / Supply Voltage | 220–240 V AC | |
| Device Type | Ammeter / voltmeter | |
| Manufacturer | Lovato Electric | |
| Series | DMK | |
| Model | DMK00R1 | |
| Product type | Single-phase digital voltmeter | |
| Measurement | AC voltage | |
| Displayed values | Present, maximum and minimum voltage | |
| Measurement method | True RMS | |
| Operating measurement range | 15 to 660 V AC | |
| Rated measuring voltage | 600 V AC | |
| Voltage accuracy | ±0.25% full scale ±1 digit | |
| Voltage input frequency | 45 to 66 Hz | |
| Auxiliary supply voltage | 220 to 240 V AC | |
| Auxiliary supply frequency | 50 / 60 Hz | |
| Maximum power consumption | 3.6 VA | |
| Maximum power dissipation | 1.8 W | |
| Relay output | 1 programmable output | |
| Relay function | Control, alarm and protection | |
| Installation type | Flush mounting | |
| Front dimensions | 96 × 48 mm | |
| Panel cut-out | approximately 92 × 45 mm | |
| Housing material | Thermoplastic | |
| Terminal type | Removable | |
| Conductor cross-section | 0.2 to 2.5 mm² | |
| Maximum terminal tightening torque | 0.8 N·m | |
| Rated insulation voltage | 600 V | |
| Protection rating | IP54 | |
| Operating temperature | -20 to +60 °C | |
| Storage temperature | -30 to +80 °C | |
| Weight | approximately 324 g | |
| Package dimensions | 123 × 58 × 98 mm | |
| EAN | 8013975154670 | |
| Conformity | IEC/EN 61010-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL508 and CSA C22.2 No. 14 | |
| HS Code | 90303100 |
The DMK00R1 measures single-phase AC voltage and displays the present, minimum and maximum measured values.
The instrument has a direct operating measurement range of approximately 15 to 660 V AC.
The programmable relay output can operate an external alarm, contactor or control circuit in response to configured voltage conditions.
Yes. It uses True RMS measurement to provide dependable readings, including when the monitored voltage waveform is distorted.
Yes. The instrument records and displays both the minimum and maximum voltage values measured during operation.
The DMK00R1 is designed for flush mounting in an electrical panel and has a 96 × 48 mm front format.
Lovato Electric digital metering instruments are used by panel builders, electrical engineers and maintenance teams to provide dependable electrical monitoring, alarm signalling and protection across industrial and commercial installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.