Finder 6M.BU.0.024.2200 - 6M Series Power analyzer

Finder 6M.BU.0.024.2200 – 6M Series Power analyzer

Finder 6M.BU.0.024.2200 is a 24 V AC/DC industrial Modbus TCP/IP to Modbus RS485 RTU gateway with an integrated web server, 10/100 Mb/s Ethernet connectivity, support for up to 200 serial devices and 10 simultaneous Ethernet clients, designed for industrial automation and energy monitoring networks.

SKU: 6M.BU.0.024.2200Alt SKU: 6MBU00242200MPN: 6M.BU.0.024.2200
Price
List Price £114.35 ex VAT
Your Price (ex VAT) Save 25%
£85.76 25% OFF
You save £28.59 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £85.76
Trade pricing is personalised to your account

Manufacturer Lead Time

£85.76

Why Choose the Finder 6M.BU.0.024.2200 Modbus TCP/IP to RS485 Gateway?

The Finder 6M.BU.0.024.2200 is an industrial Modbus TCP/IP to Modbus RS485 RTU gateway designed to connect serial Modbus devices to Ethernet-based automation and monitoring networks. Part of the Finder 6M Series, this compact communication module provides a practical interface between existing RS485 installations and modern industrial Ethernet systems.

Featuring an integrated 10/100 Mb/s Ethernet interface, an RS485 Modbus RTU master port and an onboard web server, the gateway simplifies communication between field devices and supervisory systems. It supports up to 200 Modbus RTU devices and up to 10 simultaneous Ethernet clients, making it suitable for energy monitoring, industrial automation and building management applications.

The Finder 6M.BU.0.024.2200 operates from a 24 V AC/DC power supply and provides 1,500 V electrical isolation between its power supply, RS485 and Ethernet interfaces. Its slim 17.7 mm width, 35 mm DIN rail mounting and six front-panel status LEDs make it particularly suitable for installation in industrial control cabinets where space, connectivity and straightforward diagnostics are important.

Key Advantages

  • Modbus TCP/IP to Modbus RS485 RTU conversion connects serial field devices to Ethernet networks.
  • Supports communication with up to 200 Modbus RTU devices on the serial network.
  • Allows up to 10 simultaneous Ethernet clients to access connected Modbus devices.
  • Integrated web server simplifies communication parameter configuration.
  • 10/100 Mb/s Ethernet interface provides compatibility with standard industrial Ethernet infrastructure.
  • RS485 communication speeds up to 115,200 bit/s support a wide range of Modbus RTU devices.
  • 24 V AC/DC supply compatibility offers flexibility when integrating into control panels.
  • 1,500 V galvanic isolation between power, RS485 and Ethernet interfaces helps separate connected electrical circuits.
  • Six LED status indicators provide convenient power, network and communication diagnostics.
  • 17.7 mm slimline design helps minimise DIN rail space requirements.
  • Suitable for upgrading existing RS485 installations without replacing compatible Modbus field equipment.

Key Features

  • Finder 6M Series industrial communication gateway.
  • Converts Modbus TCP/IP communications to Modbus RS485 RTU.
  • Modbus RTU master functionality for communication with serial slave devices.
  • Integrated web server for network and serial communication configuration.
  • 10/100 Mb/s Ethernet communication port.
  • RJ45 Ethernet connection.
  • RS485 serial communication interface.
  • 1,200–115,200 bit/s RS485 communication speed.
  • Up to 200 Modbus RTU slave devices.
  • Up to 10 simultaneous Ethernet clients.
  • 24 V AC/DC nominal supply voltage.
  • 19–28 V AC operating supply range.
  • 10–40 V DC operating supply range.
  • Less than 1.5 W power consumption.
  • 1,500 V isolation between the power supply, RS485 and Ethernet interfaces.
  • Six front-panel LED indicators: Power, Wait/Fail, RX, TX, Link and Activity.
  • Configurable communication settings, including support for DHCP.
  • 35 mm DIN rail mounting for industrial control cabinets.
  • IP20 protection rating.
  • −20 to +60 °C operating temperature range.
  • Compact housing with box-clamp terminal connections.

Connecting Modbus RS485 Devices to Ethernet Networks

The Finder 6M.BU.0.024.2200 acts as a communication bridge between Ethernet-based Modbus TCP/IP clients and Modbus RTU devices connected through an RS485 serial network. A compatible supervisory system, PLC, building management controller or monitoring application can communicate through the gateway to access data from connected serial devices without requiring those devices to have individual Ethernet interfaces.

The gateway's RS485 master interface supports communication with up to 200 Modbus RTU slave devices, while its Ethernet interface accommodates up to 10 simultaneous Modbus TCP/IP clients. This makes it particularly useful when integrating existing serial instrumentation, energy monitoring equipment and compatible Finder 6M Series power analysers into centralised monitoring and automation systems.

The onboard web server provides access to communication configuration settings, reducing the need for specialised configuration equipment. Six front-panel LEDs allow technicians to identify power status, Ethernet connectivity and RS485 transmit or receive activity, supporting commissioning and troubleshooting.

For reliable operation, the connected Modbus devices must use compatible serial communication settings and unique device addresses. The RS485 network should be wired, terminated and configured according to the relevant installation instructions, while the gateway should be installed inside a suitable electrical enclosure.

Typical Applications

  • Connecting Modbus RS485 RTU devices to industrial Ethernet networks.
  • Integration of Finder 6M Series power analysers into supervisory monitoring systems.
  • Industrial energy monitoring and power management networks.
  • Building management systems (BMS) and building automation.
  • PLC and SCADA communication with compatible serial Modbus equipment.
  • Electrical distribution board monitoring and data collection.
  • Industrial machinery monitoring and automation control panels.
  • Manufacturing facilities requiring centralised access to field device data.
  • Commercial building energy monitoring installations.
  • Retrofit projects upgrading existing RS485 installations to Ethernet connectivity.
  • OEM control panels and industrial communication networks.

Technical Specifications

Manufacturer Finder
Series 6M Series
Model 6M.BU.0.024.2200
Product type Industrial communication gateway
Gateway function Modbus TCP/IP to Modbus RS485 RTU
Ethernet protocol Modbus TCP/IP
Serial protocol Modbus RTU
RS485 operating mode Modbus RTU master
Ethernet interface 10/100 Mb/s
Ethernet connection RJ45
Serial interface RS485
RS485 communication speed 1,200–115,200 bit/s
Maximum Modbus RTU devices 200
Maximum simultaneous Ethernet clients 10
Integrated web server Yes
Nominal supply voltage 24 V AC/DC
AC supply operating range 19–28 V AC
DC supply operating range 10–40 V DC
Power consumption Less than 1.5 W
Electrical isolation 1,500 V between supply, RS485 and Ethernet interfaces
Status indicators 6 LEDs
LED functions Power, Wait/Fail, RX, TX, Link and Activity
Network configuration Integrated web interface and DIP-switch configuration
DHCP support Yes
Default IP address 192.168.178.29 in the default communication configuration
Default serial configuration 115,200 bit/s, 8 data bits, no parity, 1 stop bit
Operating temperature range −20 to +60 °C
Protection rating IP20
Mounting type 35 mm DIN rail
Terminal type Box-clamp terminals
Width 17.7 mm
Height 93.7 mm
Depth 63.2 mm
Dimensions (H × W × D) 93.7 × 17.7 × 63.2 mm
Applicable standards EN 61000-6-4, EN 61000-6-2 and EN 61010-1
EAN 8012823445779

Frequently Asked Questions

What is the Finder 6M.BU.0.024.2200 used for?

The Finder 6M.BU.0.024.2200 is an industrial communication gateway that connects Modbus RS485 RTU devices to Modbus TCP/IP Ethernet networks. It allows compatible monitoring systems, PLCs and supervisory applications to communicate with serial Modbus equipment.

Is the Finder 6M.BU.0.024.2200 a power analyser?

No. The Finder 6M.BU.0.024.2200 is a Modbus communication gateway, not a standalone power measurement instrument. It can be used alongside compatible Finder 6M Series power analysers and other Modbus RTU devices to make their communication data accessible over Ethernet.

How many Modbus devices can the Finder 6M.BU.0.024.2200 support?

The gateway supports communication with up to 200 Modbus RS485 RTU slave devices, subject to appropriate network design, device configuration and communication performance requirements.

How many Ethernet clients can connect to this gateway?

The Finder 6M.BU.0.024.2200 supports up to 10 simultaneous Modbus TCP/IP Ethernet clients, allowing multiple compatible systems to access connected Modbus RTU devices.

What power supply does the Finder 6M.BU.0.024.2200 require?

The gateway has a nominal supply voltage of 24 V AC/DC. Its specified operating ranges are 19–28 V AC and 10–40 V DC.

Does the Finder 6M.BU.0.024.2200 have an integrated web server?

Yes. The gateway includes an onboard web server that provides an interface for configuring Ethernet and serial communication parameters.

What Ethernet and RS485 communication speeds are supported?

The Ethernet interface supports 10/100 Mb/s networking, while the Modbus RS485 RTU interface supports communication speeds from 1,200 to 115,200 bit/s.

Does the gateway provide electrical isolation?

Yes. The Finder 6M.BU.0.024.2200 provides 1,500 V electrical isolation between its power supply, RS485 and Ethernet interfaces, helping separate the connected circuits.

Can the Finder 6M.BU.0.024.2200 be mounted on a DIN rail?

Yes. The gateway is designed for 35 mm DIN rail mounting. Its slim 17.7 mm width makes it suitable for installations where electrical cabinet space is limited.

What do the six status LEDs indicate?

The gateway includes Power, Wait/Fail, RX, TX, Link and Activity LEDs. These indicate supply status, communication conditions, RS485 data reception and transmission, Ethernet connection and network activity.

Can this gateway be used with PLC and SCADA systems?

Yes. Compatible PLC, SCADA and monitoring systems that operate as Modbus TCP/IP clients can communicate through the gateway with connected Modbus RTU devices. The system must be configured with the correct network, serial and Modbus addressing parameters.

Designed for Industrial Automation and Energy Monitoring Professionals Worldwide

The Finder 6M.BU.0.024.2200 provides a compact and practical solution for connecting Modbus RS485 equipment to Ethernet-based industrial networks. With support for up to 200 serial devices, 10 simultaneous Ethernet clients, an integrated web server and isolated communication interfaces, it is well suited to the connectivity requirements of electrical engineers, system integrators, control panel builders and industrial maintenance teams.