Finder 7E.86.8.400.0312 is a MID-certified multifunction three-phase energy meter for 3 x 230/400 V AC systems, featuring a 1 A reference current, 6 A maximum measurement current, current transformer compatibility, integrated M-Bus communication, dual-tariff and bidirectional energy measurement, programmable S0 pulse output and eight-digit backlit LCD.
£231.29
The Finder 7E.86.8.400.0312 is a multifunction three-phase digital energy meter designed for accurate electricity consumption monitoring in industrial, commercial and building management applications. Part of the Finder 7E Series, this MID-certified energy meter combines bidirectional energy measurement, dual-tariff monitoring, an integrated M-Bus communication interface and a programmable S0 pulse output.
Designed for 3 × 230/400 V AC, 50/60 Hz electrical systems, the Finder 7E.86.8.400.0312 supports three-phase installations with either three or four wires. It has a 1 A reference current and a 6 A maximum measurement current, making it suitable for use with appropriately selected current transformers (CTs).
With compatible current transformers, the meter can be configured to monitor electrical systems with substantially higher primary currents, supporting measurement applications up to 50,000 A within the manufacturer's specified configuration limits. Its programmable CT settings allow measurements to reflect the primary circuit rather than simply the current passing through the meter's measurement terminals.
An eight-digit backlit LCD display provides access to energy consumption and instantaneous electrical measurements, while the integrated M-Bus interface enables connection to compatible remote monitoring and building management systems. The meter also provides dual-tariff energy recording, bidirectional measurement and phase-related diagnostic information.
The Finder 7E.86.8.400.0312 is a practical solution for electrical engineers, energy managers, facilities teams and control panel manufacturers requiring reliable three-phase energy monitoring with wired communications and current transformer compatibility.
The Finder 7E.86.8.400.0312 measures electrical energy consumption by monitoring the voltage and current associated with a three-phase electrical installation.
The meter calculates electrical energy from the measured electrical quantities over time, allowing users to monitor consumption and analyse the performance of connected equipment.
Unlike a high-current direct-connected meter, the Finder 7E.86.8.400.0312 is particularly suited to current transformer-based measurement. Current transformers reduce the primary circuit current to a suitable secondary current that the meter can measure.
By configuring the correct CT parameters, the meter can display measurements corresponding to the actual primary circuit. This makes it suitable for monitoring larger electrical installations without routing the full load current directly through the meter.
The device supports both three-wire and four-wire three-phase systems, providing installation flexibility for different electrical distribution arrangements.
A major advantage of the Finder 7E.86.8.400.0312 is its ability to work with suitable current transformers (CTs).
The meter has a 1 A reference current and a 6 A maximum measurement current. In CT-based installations, the primary current is converted to a lower secondary current within the meter's supported measurement range.
The manufacturer's specifications identify measurement capability up to 50,000 A when appropriately configured with suitable current transformers.
Correct CT selection is essential. The transformer ratio, secondary current, accuracy, burden and installation arrangement must be compatible with the meter and the required measurement performance.
Current transformer secondary circuits must be installed and maintained using appropriate safety procedures. A CT secondary must not be left open-circuit while its primary conductor is energised unless the transformer and installation are specifically designed for that condition.
The Finder 7E.86.8.400.0312 incorporates a wired M-Bus communication interface, enabling it to exchange metering information with compatible data collection and building management equipment.
M-Bus is commonly used in utility metering and building energy monitoring systems, making this model suitable for installations where energy data needs to be collected from multiple meters.
Through a compatible M-Bus master or gateway, energy readings can be integrated into monitoring software, building management systems or wider energy reporting platforms.
The meter's M-Bus communication parameters and available data can be configured using the manufacturer's supported tools and documentation.
Important: M-Bus is not the same as Modbus RS485. Systems requiring Modbus communication should use a suitable Modbus-compatible meter or gateway.
The Finder 7E.86.8.400.0312 supports dual-tariff energy measurement, allowing consumption to be recorded separately for tariff periods T1 and T2.
This functionality can be useful where electricity usage needs to be analysed across different tariff periods, operating schedules or energy management arrangements.
The meter also supports bidirectional energy measurement, allowing it to distinguish between energy imported from the supply and energy exported in the opposite direction.
This makes it suitable for compatible installations involving distributed generation, energy recovery or other systems where electrical power may flow in more than one direction.
Its multifunction display can present total and partial energy readings, including active, apparent and reactive energy measurements, for the overall system or individual phases.
In addition to M-Bus communications, the Finder 7E.86.8.400.0312 provides a programmable S0 pulse output.
An S0 output generates electrical pulses associated with measured energy, allowing compatible pulse counters, monitoring modules and data acquisition equipment to record consumption.
This provides an additional method of integrating the meter into existing monitoring systems where a pulse input is available.
The pulse output settings and electrical interface requirements should be checked against Finder's documentation and the connected monitoring equipment.
The Finder 7E.86.8.400.0312 features an eight-digit backlit LCD display, providing convenient access to electrical measurements without requiring a separate monitoring device.
Users can scroll through measurements including voltage, current, active power, apparent power, reactive power, power factor and frequency.
The meter also indicates power-flow direction and provides diagnostic information for conditions such as phase loss or incorrect phase sequence.
These functions make it useful not only for recording energy consumption but also for understanding the operating characteristics of a three-phase electrical installation.
The Finder 7E.86.8.400.0312 is designed for 35 mm DIN rail mounting in accordance with EN 60715, allowing installation inside suitable electrical distribution boards, industrial control cabinets and metering enclosures.
The meter occupies four modular spaces and uses screw terminal electrical connections.
Installation should be carried out by a competent electrical professional, with particular attention to the correct three-phase wiring configuration, voltage connections, CT polarity, CT ratio settings and communications wiring.
For installations requiring MID-compliant measurement, the meter must be selected, configured and installed in accordance with the applicable regulations and the manufacturer's instructions.
The device is a measurement instrument, not a protective circuit breaker or an electrical isolator. Suitable circuit protection and isolation must be provided separately.
Tick the specs you need, then view products that match.
| Mounting Type | DIN rail | |
|---|---|---|
| Monitored Supply | Three-phase | |
| Monitoring Function | Three-phase supply | |
| Manufacturer | Finder | |
| Series | 7E Series | |
| Type | 7E.86 | |
| Model | 7E.86.8.400.0312 | |
| Product type | Multifunction three-phase digital energy meter | |
| Measurement technology | Electronic energy measurement | |
| Electrical system | Three-phase AC | |
| Wiring configuration | Three- or four-wire systems | |
| Nominal system voltage | 3 × 230/400 V AC | |
| Phase-to-neutral voltage range | 184–276 V AC | |
| Operating frequency | 50/60 Hz | |
| Reference current | 1 A | |
| Maximum measurement current | 6 A | |
| Listed operating measurement current | 0.05–6 A | |
| Current transformer compatibility | Yes | |
| CT secondary configuration | Programmable | |
| Maximum primary current measurement capability | Up to 50,000 A with suitable CTs | |
| Measurement direction | Bidirectional | |
| Tariff configuration | Dual tariff, T1 and T2 | |
| Tariff control | External | |
| Communication interface | Integrated M-Bus | |
| Pulse output | Single programmable S0 output | |
| Display | Backlit LCD | |
| Display digits | 8 | |
| Energy counting range | Up to 999,999.99 kWh | |
| Active energy measurement | kWh | |
| Apparent energy measurement | kVAh | |
| Reactive energy measurement | kvarh | |
| Instantaneous measurements | V, A, PF, kW, kVA, kvar and Hz | |
| Additional indication | Power-flow direction, phase loss and phase sequence faults | |
| Active energy accuracy | Class B, EN 50470-3 | |
| Reactive energy accuracy | Class 2, EN 62053-23 | |
| Certification | MID | |
| Power consumption | Approximately 0.5 W | |
| Operating temperature | −25 to +55 °C | |
| Protection rating | IP50 | |
| Protection category | II | |
| Mounting | 35 mm DIN rail | |
| DIN rail standard | EN 60715 | |
| Housing width | 4 modular spaces | |
| Electrical connections | Screw terminals | |
| EAN | 8012823412665 |
The Finder 7E.86.8.400.0312 is a multifunction three-phase energy meter used to monitor electrical consumption, power and other electrical parameters in industrial and commercial installations. It supports current transformer measurement, M-Bus communications and dual-tariff recording.
Yes. The Finder 7E.86.8.400.0312 is a MID-certified energy meter, with active energy measurement accuracy Class B according to EN 50470-3.
The meter is designed for 3 × 230/400 V AC, 50/60 Hz three-phase electrical systems and supports suitable three- or four-wire configurations.
The meter has a 1 A reference current and a 6 A maximum measurement current. With suitable current transformers and correct configuration, it can monitor primary currents up to 50,000 A.
Yes. The meter supports current transformer-based measurement and programmable CT settings. Suitable transformers must be selected and installed according to the manufacturer's specifications.
Yes. The meter has an integrated wired M-Bus interface for connection to compatible remote energy monitoring, data collection and building management systems.
No. M-Bus and Modbus are different communication protocols. The Finder 7E.86.8.400.0312 uses M-Bus, so a compatible M-Bus master or gateway is required for communication.
Yes. The meter supports two tariff registers, T1 and T2, allowing electrical energy consumption to be recorded separately for different tariff periods.
Yes. The meter supports bidirectional energy measurement, allowing monitoring of both imported and exported electrical energy in compatible installations.
The eight-digit backlit LCD can display energy readings and instantaneous electrical measurements including voltage, current, power factor, active power, apparent power, reactive power, frequency and power-flow direction.
Yes. The meter includes a single programmable S0 pulse output for connection to compatible energy monitoring and pulse-counting equipment.
Yes. It is designed for 35 mm DIN rail mounting according to EN 60715 and occupies four modular spaces.
The Finder 7E.78.8.400.0312 is a direct-connected three-phase meter rated up to 80 A. The Finder 7E.86.8.400.0312 has a 6 A maximum measurement current and supports current transformer measurement for higher-current installations. Both provide M-Bus communication, dual-tariff measurement and MID certification.
The Finder 7E.86.8.400.0312 combines MID-certified three-phase energy measurement, current transformer compatibility, integrated M-Bus communication and dual-tariff monitoring in a compact DIN rail-mounted device. Its multifunction LCD display, bidirectional measurement and programmable S0 output make it a practical solution for electrical engineers, energy managers, building services professionals and industrial control panel manufacturers.
We use cookies