Finder 7E.85.8.400.0312 - 7E Series Energy Meters

Finder 7E.85.8.400.0312 – 7E Series Energy Meters

Finder 7E.85.8.400.0312 is a MID Class C multifunction three-phase bi-directional energy meter featuring 1 A reference and 6 A maximum CT inputs, programmable current transformer ratios up to 10000 A, dual-tariff measurement, M-Bus communication, two S0 pulse outputs and a backlit LCD display for industrial and commercial energy monitoring.

SKU: 7E.85.8.400.0312Alt SKU: 7E8584000312MPN: 7E.85.8.400.0312
Price
List Price £262.36 ex VAT
Your Price (ex VAT) Save 25%
£196.77 25% OFF
You save £65.59 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £196.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£196.77

Why Choose the Finder 7E.85.8.400.0312 Three-Phase Energy Meter?

The Finder 7E.85.8.400.0312 is an advanced three-phase multifunction, bi-directional energy meter designed for accurate electricity monitoring, industrial energy management and building automation. Part of the Finder 7E Series, this MID-certified digital electricity meter combines high-precision energy measurement, dual-tariff recording, an integrated M-Bus communication interface and two S0 pulse outputs in a compact DIN rail-mounted enclosure.

Designed for use with external current transformers (CTs), the Finder 7E.85.8.400.0312 supports a 1 A reference current and 6 A maximum measuring input, allowing the monitoring of substantially higher installation currents through appropriately selected and configured CTs. Its programmable transformer ratio supports installations with primary currents up to 10,000 A, making it suitable for industrial distribution boards, commercial electrical installations and energy-intensive manufacturing facilities.

The meter supports three-phase three-wire and three-phase four-wire electrical systems, with a nominal supply of 3 × 230/400 V AC. Its illuminated LCD display provides access to active and reactive energy, voltage, current, power, power factor, frequency and harmonic distortion information. With accuracy class 0.5S / MID Class C, import and export energy recording, M-Bus remote communication and two-tariff operation, this Finder energy meter offers a comprehensive solution for professional electricity monitoring and consumption analysis.

Key Advantages

  • MID-certified energy measurement for applications requiring a compliant electricity meter, subject to applicable metering regulations.
  • Class 0.5S / MID Class C accuracy provides precise active energy measurement.
  • Bi-directional metering separately records imported and exported electrical energy.
  • Dual-tariff functionality supports electricity consumption monitoring across two tariff periods.
  • Integrated M-Bus communication enables remote meter reading and connection to compatible building management systems.
  • Two S0 pulse outputs support integration with pulse counters, monitoring equipment and automation systems.
  • Current transformer operation allows measurement of high-current installations without routing the main load current through the meter.
  • Programmable CT ratio supports applications with primary currents up to 10,000 A using suitable transformers.
  • Three-phase three-wire and four-wire compatibility provides installation flexibility.
  • Backlit LCD display provides convenient local access to electrical measurements.
  • Multifunction electrical monitoring includes voltage, current, active power, reactive power, apparent power, frequency and power factor.
  • Total harmonic distortion measurement helps identify voltage and current waveform distortion.
  • Maximum demand monitoring supports electrical load analysis and energy management.
  • Compact four-module DIN rail housing saves space in electrical distribution boards.
  • IP51 protection rating provides protection suitable for specified indoor installation conditions.
  • Wide operating temperature range supports demanding industrial and commercial environments.

Key Features

  • Finder 7E Series multifunction energy meter.
  • Type 7E.85 three-phase digital electricity meter.
  • Bi-directional active and reactive energy measurement.
  • MID Class C certification.
  • Class 0.5S active energy accuracy according to the applicable measurement standard.
  • 1 A reference current / 6 A maximum current.
  • External current transformer connection.
  • Programmable CT primary current up to 10,000 A.
  • Nominal voltage of 3 × 230/400 V AC.
  • 100–277 V AC line-to-neutral operating range.
  • 100–480 V AC line-to-line operating range.
  • 50/60 Hz operating frequency.
  • Three-phase three-wire and four-wire configurations.
  • Two selectable electricity tariffs.
  • Integrated M-Bus interface compliant with EN 13757-3.
  • Two S0 pulse outputs, including a programmable output.
  • Backlit eight-digit LCD energy display.
  • Front-panel programming and navigation buttons.
  • Voltage, current and power measurements for comprehensive electrical monitoring.
  • Power factor, frequency and harmonic distortion measurements.
  • Maximum demand measurement.
  • 35 mm DIN rail mounting according to EN 60715.
  • Four-module housing width of approximately 72 mm.
  • IP51 protection rating.
  • Operating ambient temperature range of −40 to +70 °C.
  • Sealable terminal covers for metering installation security.

Advanced Three-Phase Energy Monitoring, M-Bus Communication and Dual-Tariff Measurement

The Finder 7E.85.8.400.0312 is designed to provide detailed electrical consumption information in industrial and commercial installations. Unlike a basic kilowatt-hour counter, this multifunction energy meter measures a broad range of electrical parameters, allowing engineers and energy managers to understand how electricity is being consumed, distributed and returned to the supply network.

Its bi-directional measurement capability allows the meter to record both imported and exported electrical energy. This is especially valuable in installations incorporating on-site electricity generation, such as photovoltaic systems, where electrical energy may flow in either direction. Separate import and export measurements support more detailed energy analysis and reporting.

The meter operates with external current transformers, rather than carrying the main installation current directly through its measuring terminals. With a 1 A reference current and 6 A maximum current input, the device can monitor high-current installations when used with correctly selected and configured CTs. The programmable transformer ratio supports primary currents up to 10,000 A.

The dual-tariff function enables energy consumption to be recorded across two tariff periods. This is useful for installations where electricity is charged at different rates according to operating schedules, time periods or energy supply arrangements. The tariff configuration should be matched to the actual metering and control requirements of the installation.

A key feature of the 7E.85.8.400.0312 variant is its integrated M-Bus communication interface. M-Bus is widely used for remote meter reading in commercial buildings, industrial facilities and energy management systems. The interface supports the EN 13757-3 protocol, allowing compatible systems to collect electrical measurement data without relying solely on manual display readings.

The meter also includes two S0 pulse outputs. These provide additional integration options for external pulse counters, building management systems and monitoring equipment. One output is programmable, offering flexibility when configuring the energy monitoring system.

Its backlit LCD display provides local access to key electrical measurements. The available information includes phase and line voltages, phase currents, active power, reactive power, apparent power, power factor and frequency. Energy totals can be used to analyse electrical consumption over time, while the additional measurement functions support investigation of electrical load conditions.

The Finder 7E.85 also provides total harmonic distortion measurements for current and voltage. These measurements can help identify waveform distortion associated with non-linear loads such as variable speed drives, electronic power supplies and industrial power conversion equipment. Maximum demand monitoring provides further information for assessing electrical load peaks.

With MID Class C certification and Class 0.5S active energy accuracy, the meter is designed for applications requiring dependable electrical energy measurement. The relevant national regulations, installation conditions and certification requirements must be checked before using the meter for billing or other legally controlled metering applications.

The four-module DIN rail housing allows the meter to be installed within electrical distribution boards and industrial control panels. Its compact dimensions, sealable terminal covers and IP51 protection rating make it suitable for properly designed indoor electrical installations. The specified operating temperature range of −40 to +70 °C supports use in demanding environments.

For correct operation, the installer must configure the appropriate three-phase wiring system, current transformer ratio, tariff settings and M-Bus communication parameters. CT polarity, phase sequence and voltage connections are particularly important for accurate import and export measurement. Installation and commissioning should be carried out by a suitably qualified electrical professional in accordance with Finder's instructions and applicable electrical regulations.

Typical Applications

  • Industrial three-phase electricity consumption monitoring.
  • Commercial building energy management systems.
  • Factory and manufacturing plant electrical monitoring.
  • Electrical distribution boards and sub-metering installations.
  • Building management systems using M-Bus communication.
  • Industrial energy efficiency and consumption analysis.
  • Photovoltaic installations requiring import and export energy measurement.
  • High-current installations using external current transformers.
  • Dual-tariff electricity consumption monitoring.
  • Industrial machinery and production line energy measurement.
  • Commercial and industrial tenant sub-metering, where permitted.
  • Energy management and monitoring dashboards.
  • Remote electricity meter reading systems.
  • Industrial power factor and harmonic distortion monitoring.
  • Electrical load and maximum demand analysis.
  • Energy reporting and operational cost monitoring.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type DIN rail
Monitored Supply Three-phase
Monitoring Function Three-phase supply
Manufacturer Finder
Series 7E Series
Model 7E.85.8.400.0312
Product type Multifunction three-phase energy meter
Meter type Electronic, current transformer-operated
Measurement direction Bi-directional, import and export
Number of phases Three-phase
Supported electrical systems Three-phase three-wire and three-phase four-wire
Nominal voltage 3 × 230/400 V AC
Line-to-neutral operating voltage 100–277 V AC
Line-to-line operating voltage 100–480 V AC
Rated frequency 50/60 Hz
Reference current 1 A
Maximum measuring current 6 A
Minimum measured current 0.05 A
Starting current 0.005 A
Measuring current range 0.05–6 A
Maximum short-duration peak current 120 A for 500 ms
Current transformer compatibility External CT connection
CT ratio configuration Programmable
Maximum supported CT primary current 10,000 A
Active energy accuracy Class 0.5S according to IEC 62053-22
MID accuracy classification Class C
Reactive energy accuracy Class 2 according to IEC 62053-23
MID certification Yes
MID operating temperature certification Up to +70 °C
Tariff functionality Dual tariff
Communication interface M-Bus
Communication protocol EN 13757-3
M-Bus baud rates 600, 1200, 2400, 4800 and 9600 baud
M-Bus primary address range 001–250
M-Bus secondary addressing Supported
Pulse outputs 2 × S0
Programmable pulse output Yes
Display type Backlit LCD
Energy counter display Eight digits
Maximum displayed energy count 999,999.99 kWh
Minimum energy display increment 0.01 kWh
Measured energy Imported, exported and total active energy; imported, exported and total reactive energy
Measured electrical parameters Voltage, current, active power, reactive power, apparent power, power factor and frequency
Additional measurements Current and voltage total harmonic distortion, maximum demand
Front-panel controls Four buttons
Mounting type DIN rail
DIN rail standard EN 60715, 35 mm
Housing width 71.9 mm
Housing height 99.4 mm
Housing depth Approximately 59.6 mm, excluding installation-dependent clearances
DIN module width 4 modules
Protection rating IP51
Operating ambient temperature −40 to +70 °C
Terminal protection Sealable terminal covers
EAN 8012823461403

Frequently Asked Questions

What is the Finder 7E.85.8.400.0312 used for?

The Finder 7E.85.8.400.0312 is a multifunction three-phase energy meter used for monitoring electricity consumption, imported and exported energy, electrical power and other parameters in industrial and commercial installations. It includes dual-tariff measurement, M-Bus communication and two S0 pulse outputs.

Is the Finder 7E.85.8.400.0312 MID certified?

Yes. The Finder 7E.85.8.400.0312 is MID certified in accuracy Class C, with certification covering operation up to +70 °C. Suitability for legally controlled metering depends on the applicable regulations and installation requirements.

Does the Finder 7E.85.8.400.0312 require current transformers?

Yes. The meter is designed for external current transformer operation, with a 1 A reference current and 6 A maximum measuring input. Suitable CTs must be selected and their ratio correctly configured in the meter.

What is the maximum current the Finder 7E.85.8.400.0312 can measure?

The meter has a 6 A maximum current input and supports external current transformers with programmable primary current values up to 10,000 A. The actual installation current must be measured through appropriately rated CTs rather than connected directly to the meter's current inputs.

What communication protocol does the Finder 7E.85.8.400.0312 use?

The Finder 7E.85.8.400.0312 has an integrated M-Bus interface compliant with EN 13757-3. It supports remote meter reading and integration with compatible energy management and building automation systems.

Does the Finder 7E.85.8.400.0312 support Modbus RS485?

No. The 7E.85.8.400.0312 uses M-Bus communication. For applications requiring Modbus RS485, the corresponding Finder 7E.85.8.400.0212 variant should be considered.

Can the Finder 7E.85.8.400.0312 measure exported solar energy?

Yes. The meter supports bi-directional energy measurement, allowing imported and exported active energy to be recorded separately. This makes it suitable for monitoring electrical installations with on-site generation, including appropriately configured photovoltaic systems.

Does the Finder 7E.85.8.400.0312 support dual tariffs?

Yes. The 7E.85.8.400.0312 is a dual-tariff energy meter, allowing energy consumption to be recorded across two tariff periods according to the configured tariff control arrangement.

How many pulse outputs does the Finder 7E.85.8.400.0312 have?

The meter provides two S0 pulse outputs, including a programmable output. These can be used with compatible pulse counters, data acquisition equipment and building energy management systems.

What electrical parameters can the Finder 7E.85.8.400.0312 measure?

The meter measures active and reactive energy, voltage, current, active power, reactive power, apparent power, power factor, frequency, maximum demand and total harmonic distortion. It also provides separate imported and exported energy readings.

Can the Finder 7E.85.8.400.0312 be used on three-wire and four-wire systems?

Yes. The meter supports three-phase three-wire and three-phase four-wire electrical systems. The appropriate supply configuration must be selected during commissioning and wired according to the manufacturer's installation instructions.

What is the difference between the Finder 7E.85.8.400.0312 and 7E.85.8.400.0310?

Both models provide M-Bus communication, current transformer operation and multifunction three-phase energy measurement. The main difference is tariff functionality: the 7E.85.8.400.0312 supports two tariffs, while the 7E.85.8.400.0310 is a single-tariff version.

What is the difference between the Finder 7E.85.8.400.0312 and 7E.85.8.400.0212?

Both models provide dual-tariff, bi-directional three-phase energy measurement with two S0 pulse outputs. The key difference is communication: the 7E.85.8.400.0312 uses M-Bus, while the 7E.85.8.400.0212 uses Modbus RS485.

How is the Finder 7E.85.8.400.0312 mounted?

The meter is designed for 35 mm DIN rail mounting according to EN 60715. Its housing is approximately 71.9 mm wide, occupying four standard DIN modules.

Trusted by Industrial Energy Management Professionals Worldwide

Finder 7E Series energy meters provide advanced electricity measurement and monitoring solutions for industrial facilities, commercial buildings and electrical distribution systems. With MID Class C certification, current transformer operation, bi-directional measurement, dual-tariff recording, integrated M-Bus communication, two S0 pulse outputs and a compact DIN rail design, the Finder 7E.85.8.400.0312 is a versatile choice for electrical engineers, energy managers, building automation specialists and industrial control panel manufacturers.