Finder 7E.85.8.400.0310 is a three-phase multifunction bi-directional energy meter with MID-certified Class C / 0.5S active energy accuracy, current transformer measurement, integrated M-Bus communication, single-tariff functionality, two S0 pulse outputs and a backlit LCD display. Designed for industrial and commercial energy monitoring.
£186.05
The Finder 7E.85.8.400.0310 is a high-accuracy three-phase multifunction bi-directional energy meter designed for professional electricity monitoring, industrial energy management and building automation applications. Part of the Finder Series 7E, this advanced digital electricity meter combines current transformer (CT) measurement, an integrated M-Bus communication interface, single-tariff energy measurement and two S0 pulse outputs in a compact DIN rail mounted housing.
Designed for three-phase electrical systems with or without a neutral conductor, the Finder 7E.85.8.400.0310 provides comprehensive monitoring of electricity consumption, energy export and electrical network performance. Its nominal 3 × 230/400 V AC measurement voltage, 1 A reference current and 6 A maximum measurement input current make it suitable for indirect electricity measurement through appropriately selected current transformers.
With support for current transformer ratios corresponding to primary currents of up to 10,000 A, this three-phase electricity meter is particularly useful for monitoring larger commercial and industrial electrical installations. Its MID-certified Class C (0.5S) active energy accuracy supports precise measurement in demanding electrical environments.
The integrated M-Bus interface allows measured energy values and electrical parameters to be transmitted to compatible building management systems, energy monitoring gateways and data acquisition platforms. Combined with bi-directional energy measurement, a backlit LCD display and configurable pulse outputs, the Finder 7E.85.8.400.0310 provides a practical solution for modern electrical energy monitoring.
The Finder 7E.85.8.400.0310 is designed to measure electrical energy flowing in both directions through a compatible three-phase installation. This allows users to monitor energy imported from an electricity supply and energy exported from installations incorporating suitable on-site generation equipment.
Bi-directional energy measurement is particularly valuable in commercial buildings, manufacturing facilities and renewable energy installations where electricity may be both consumed and generated. Separate import and export measurements help provide a clearer understanding of the site's electrical energy balance.
The meter supports measurement of active energy in kWh and reactive energy in kvarh, alongside instantaneous electrical quantities such as voltage, current, active power, apparent power, reactive power, frequency and power factor.
Its ability to monitor total harmonic distortion (THD) provides additional information about the electrical network. THD measurements can help engineers assess the presence of harmonic distortion associated with non-linear electrical loads, although the meter is not a substitute for a dedicated power quality analyser where detailed harmonic investigations are required.
With Class C / 0.5S active energy accuracy and MID certification, the Finder 7E.85.8.400.0310 is suitable for applications requiring precise electrical energy measurement, subject to the applicable metering regulations and installation requirements.
Unlike direct-connected electricity meters, the Finder 7E.85.8.400.0310 uses external current transformers (CTs) to measure electrical current. These transformers convert the higher currents flowing through the monitored conductors into lower secondary currents suitable for the meter's measurement inputs.
The meter has a 1 A reference current and a 6 A maximum measurement input current. When configured with suitable current transformers, it can monitor installations with primary currents up to 10,000 A.
This indirect measurement arrangement makes the Finder 7E.85.8.400.0310 particularly suitable for larger electrical distribution systems, industrial machinery and commercial installations where direct-connected meters would not be appropriate.
The current transformer ratio must be configured correctly so that the displayed and communicated values accurately represent the electrical installation. Incorrect CT ratios, polarity or phase association can lead to inaccurate readings or incorrect identification of import and export energy.
For MID-controlled installations, the current transformer configuration must comply with the manufacturer's instructions and applicable metering requirements.
Important safety information: Current transformer secondary circuits must be installed and maintained using appropriate electrical safety procedures. A CT secondary must not be left open-circuit while its primary conductor is energised.
The Finder 7E.85.8.400.0310 incorporates an M-Bus communication interface designed for remote electricity monitoring and integration with compatible energy management systems.
M-Bus, or Meter-Bus, is a communication system widely used for utility metering and building services applications. It allows compatible meters to communicate measurement data to central collection equipment, making it particularly useful for installations that require automated energy reporting.
The meter's M-Bus communication implementation is compatible with EN 13757-3 and supports configurable baud rates of 600, 1200, 2400, 4800 and 9600 bps.
Its configurable M-Bus primary address range of 001–250 allows the device to be integrated into appropriately designed multi-meter networks. Secondary addressing provides additional flexibility when identifying devices on a compatible M-Bus system.
When connected to a suitable M-Bus master or energy monitoring gateway, the meter can provide data for electricity consumption analysis, operational reporting and building energy management.
Important: The Finder 7E.85.8.400.0310 uses M-Bus communication, not RS485 Modbus RTU. The two protocols are not directly interchangeable, and a suitable interface or gateway is required when integrating an M-Bus meter into a system that only supports Modbus.
The Finder 7E.85.8.400.0310 is the single-tariff version of Finder's M-Bus-enabled Type 7E.85 energy meter.
Its single-tariff configuration is ideal for installations where energy consumption is recorded using one tariff register rather than being separated into multiple tariff periods.
This makes it suitable for industrial sub-metering, energy performance monitoring, building services measurement and installations where tariff switching is not required.
For applications requiring two tariff registers, the corresponding Finder 7E.85.8.400.0312 model provides dual-tariff functionality while retaining the M-Bus communication interface.
Choosing the correct tariff version at the design stage helps ensure that the meter provides the functionality required by the monitoring system.
In addition to its M-Bus communication interface, the Finder 7E.85.8.400.0310 provides two S0 pulse outputs for integration with compatible monitoring equipment.
S0 pulse outputs allow energy-related information to be represented as electrical pulses that can be counted by suitable controllers, data loggers or energy monitoring interfaces.
Finder's Type 7E.85 range includes a programmable pulse output, supporting flexible energy monitoring arrangements. Pulse output configuration should follow the manufacturer's instructions and the requirements of the connected equipment.
The combination of M-Bus communication and S0 pulse outputs makes the meter suitable for both digital network integration and pulse-based energy monitoring systems.
The Finder 7E.85.8.400.0310 is designed for mounting on a standard 35 mm DIN rail within a suitable electrical distribution board or industrial control cabinet.
Its compact dimensions of approximately 71.9 × 99.4 × 59.6 mm allow it to occupy approximately four standard modular positions.
The meter can be configured for compatible three-phase three-wire or four-wire electrical networks. Correct wiring and network configuration are essential to ensure accurate energy measurement.
The voltage measurement connections and external current transformers must be installed according to the manufacturer's wiring diagrams. Each current transformer must be connected to the appropriate phase with the correct polarity and configured with the correct transformation ratio.
The device also requires an appropriate auxiliary supply. The manufacturer's documentation specifies an auxiliary supply operating range of 100–480 V AC or 140–680 V DC.
For M-Bus communication, the meter must be connected to a compatible M-Bus master or gateway using suitable cabling and network installation practices.
Electrical installation and commissioning should be carried out by suitably qualified personnel. The meter is a measurement device and does not replace circuit breakers, isolators or other required electrical protection equipment.
Tick the specs you need, then view products that match.
| Mounting Type | DIN rail | |
|---|---|---|
| Manufacturer | Finder | |
| Series | 7E | |
| Manufacturer part number | 7E.85.8.400.0310 | |
| Product type | Multifunction bi-directional electricity meter | |
| Meter configuration | Three-phase, single tariff | |
| Measurement method | Current transformer operated | |
| Supported electrical networks | Three-phase three-wire and four-wire | |
| Nominal system voltage | 3 × 230/400 V AC | |
| Line-to-neutral operating voltage | 100–277 V AC | |
| Line-to-line operating voltage | 100–480 V AC | |
| Nominal frequency | 50/60 Hz | |
| Reference current | 1 A | |
| Maximum measurement input current | 6 A | |
| Minimum measured current | 0.05 A | |
| Starting current | 0.005 A | |
| Maximum short-duration peak current | 120 A for 0.5 s | |
| Maximum supported CT primary current | 10,000 A with suitable current transformers | |
| Active energy accuracy | Class C / 0.5S | |
| Reactive energy accuracy | Class 2 | |
| MID certification | Yes | |
| MID notified body | 0598 | |
| MID certificate reference | 0598/MID/B/24/061 | |
| Energy measurement direction | Bi-directional, import and export | |
| Energy quantities | Active and reactive energy | |
| Additional measurements | Voltage, current, frequency, active power, reactive power, apparent power, power factor and THD | |
| Communication interface | M-Bus | |
| Communication protocol | EN 13757-3 compatible M-Bus | |
| Supported M-Bus baud rates | 600, 1200, 2400, 4800 and 9600 bps | |
| M-Bus primary address range | 001–250 | |
| M-Bus secondary address | Configurable | |
| Pulse outputs | 2 × S0 | |
| Tariff functionality | Single tariff | |
| Display type | Backlit LCD | |
| Maximum energy register display | 999,999.99 kWh | |
| Minimum energy register increment | 0.01 kWh | |
| Auxiliary supply AC operating range | 100–480 V AC | |
| Auxiliary supply DC operating range | 140–680 V DC | |
| Auxiliary supply consumption | Less than 10 VA | |
| Mounting type | 35 mm DIN rail | |
| Housing width | 71.9 mm | |
| Housing height | 99.4 mm | |
| Housing depth | 59.6 mm | |
| Operating ambient temperature | −40 to +70 °C | |
| EAN / GTIN | 8012823461380 |
The Finder 7E.85.8.400.0310 is a three-phase multifunction bi-directional energy meter used to monitor electricity consumption, energy export and electrical parameters in industrial and commercial installations. It supports current transformer measurement, M-Bus communication and single-tariff monitoring.
Yes. The meter is designed for compatible three-phase three-wire and four-wire electrical systems with a nominal measurement voltage of 3 × 230/400 V AC.
Yes. The meter includes an integrated M-Bus interface compatible with the EN 13757-3 communication standard. It can communicate with suitable M-Bus masters, gateways and energy monitoring systems.
No. The Finder 7E.85.8.400.0310 uses M-Bus, not Modbus RS485. For an equivalent single-tariff meter with integrated Modbus RS485 communication, consider the Finder 7E.85.8.400.0210.
The meter provides Class C / 0.5S active energy accuracy and is MID certified. Reactive energy measurement is specified to Class 2.
Yes. The meter is designed for indirect current measurement using external current transformers. Suitable CTs must be selected and configured according to the installation and the manufacturer's instructions.
The meter has a 6 A maximum measurement input current. When used with suitable current transformers, it supports indirect measurement of primary currents up to 10,000 A.
Yes. The meter supports bi-directional energy measurement, allowing monitoring of electricity imported from and exported to the electrical network in compatible installations.
No. The Finder 7E.85.8.400.0310 is the single-tariff version. For dual-tariff measurement with M-Bus communication, choose the Finder 7E.85.8.400.0312.
Both are three-phase bi-directional multifunction energy meters with current transformer measurement, M-Bus communication and two S0 pulse outputs. The main difference is the tariff configuration: the 7E.85.8.400.0310 is a single-tariff meter, while the 7E.85.8.400.0312 supports dual-tariff measurement.
Finder Series 7E energy meters provide dependable electrical measurement and communication capabilities for modern industrial and commercial installations. The Finder 7E.85.8.400.0310 combines MID-certified Class C / 0.5S accuracy, bi-directional three-phase energy measurement, current transformer compatibility, M-Bus communication and single-tariff monitoring in a compact DIN rail mounted design, making it a practical choice for advanced energy management and electrical monitoring.