EM28072DMV63XOSN - EM280 Energy analyser, 120V LN/230V LL AC

EM28072DMV63XOSN – EM280 Energy analyser, 120V LN/230V LL AC

Carlo Gavazzi EM28072DMV63XOSN three-phase energy analyser for multi-load metering, 160-240 V L-N, 277-415 V L-L, 32 A input, RS485 Modbus RTU and pulse output.

SKU: EM28072DMV63XOSNMPN: EM28072DMV63XOSN
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Carlo Gavazzi EM28072DMV63XOSN Energy Analyser?

The Carlo Gavazzi EM28072DMV63XOSN is a compact and reliable three-phase energy analyser designed for accurate multi-load electrical measurement in industrial, commercial and building energy monitoring applications. As part of the Carlo Gavazzi EM280 compact quick-fit energy analyser range, it provides efficient monitoring of electrical consumption across multiple single-phase or three-phase loads.

This analyser supports direct current input up to 32 A, with a maximum current capability of 36 A, and includes RS485 Modbus RTU communication for straightforward integration with PLCs, SCADA systems, building management platforms and energy monitoring networks. Its compact design helps reduce panel space while simplifying installation.

Operating across 160–240 V L-N and 277–415 V L-L networks, the EM28072DMV63XOSN is suitable for monitoring 230/400 V AC electrical systems. It can monitor up to six single-phase loads or two three-phase loads, making it ideal for energy reporting, consumption analysis and multi-circuit metering applications.

Key Advantages

  • Compact three-phase energy analyser for multi-load metering.
  • Monitors up to six single-phase loads or two three-phase loads.
  • 160–240 V L-N / 277–415 V L-L voltage input range.
  • 32 A direct current input with 36 A maximum capability.
  • RS485 Modbus RTU communication for automation and monitoring systems.
  • Pulse output for energy counting and system integration.

Key Features

  • Carlo Gavazzi EM280 energy analyser series.
  • Three-phase multi-load energy analyser.
  • Direct connection up to 32 A.
  • RS485 Modbus RTU communication.
  • Static pulse output for energy monitoring.
  • Measures consumption and generated energy.
  • Compatible with split-core and solid-core multi-load sensors.
  • DIN rail and panel mounting capability.

Accurate Multi-Load Energy Monitoring

Energy analysers such as the Carlo Gavazzi EM28072DMV63XOSN allow multiple circuits to be monitored from a single compact device, helping reduce the need for separate meters across every load. This supports clearer energy reporting, improved consumption visibility and more effective monitoring of electrical system performance.

The integrated RS485 Modbus RTU interface enables reliable communication with automation and energy management systems. This makes the EM28072DMV63XOSN well suited to industrial panels, commercial distribution boards and smart building installations where accurate real-time energy data is required.

Typical Applications

  • Industrial energy monitoring systems.
  • Commercial building energy management.
  • Distribution boards and switchboards.
  • Control panels and automation cabinets.
  • Machine and process energy analysis.
  • Panel building and OEM electrical equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Measurement Connection Type CT connection
MID Approval No
Current Input Rating (A) 32 A
Measurement Functions Energy, Power
Device Type Power / energy analyser
Phase Three Phase
Signal / Input Range AC V / A (TRMS), CT input (/5 A or /1 A)
Coil / Supply Voltage Self-powered
Communication Modbus RTU, RS485
Voltage 120 V
Manufacturer Carlo Gavazzi
Series EM280
Model EM28072DMV63XOSN
Product type Three-phase energy analyser
Voltage input 160–240 V L-N / 277–415 V L-L
Network compatibility Single-phase and three-phase systems
Current input Direct connection up to 32 A
Maximum current 36 A
Frequency 50 / 60 Hz
Communication RS485 Modbus RTU
Output Pulse / static output
Energy metering Consumption and generation
Supported loads Up to 6 single-phase loads or 2 three-phase loads
Power supply Self-powered
Mounting type DIN rail / panel mounting
Approvals CE, cULus, UKCA

Frequently Asked Questions

What is the Carlo Gavazzi EM28072DMV63XOSN used for?

The EM28072DMV63XOSN is used to measure and monitor electrical energy across multiple single-phase or three-phase loads in industrial, commercial and building energy systems.

How many loads can this analyser monitor?

It can monitor up to six single-phase loads or two three-phase loads, depending on the installation configuration.

What voltage range does the EM28072DMV63XOSN support?

The unit supports 160–240 V L-N and 277–415 V L-L electrical networks.

Does this energy analyser support Modbus communication?

Yes, the EM28072DMV63XOSN includes RS485 Modbus RTU communication for integration with automation, monitoring and building management systems.

Where is this analyser typically installed?

It is typically installed inside control panels, distribution boards, switchboards and electrical metering enclosures using DIN rail or panel mounting.

Trusted by Energy Management Professionals Worldwide

Carlo Gavazzi EM280 energy analysers are trusted by panel builders, electrical contractors and automation engineers for compact multi-load metering, accurate energy monitoring and dependable integration into modern energy management systems.