ABB A41 313-100 single-phase direct-connected DIN-rail energy meter rated up to 80 A, with active and reactive import/export measurement, Class B MID accuracy, four-tariff capability, two inputs, two outputs and integrated M-Bus communication.
£288.64
The ABB A41 313-100 is an advanced single-phase direct-connected DIN-rail energy meter designed for detailed electricity monitoring in commercial, industrial and building energy-management applications. Part of ABB's DIN Rail Mounted Meters range, it combines direct measurement up to 80 A, active and reactive energy monitoring and a large backlit display in a compact DIN-rail format.
The A41 313-100 supports import and export measurement, with separate registers and a total energy register, together with a resettable intermediate register and support for up to four tariffs. It provides Class B MID / IEC Class 1 active-energy accuracy and measures both active and reactive energy, making it suitable for detailed submetering and energy-management applications.
Integrated M-Bus communication enables energy and instrumentation data to be incorporated into compatible automatic meter-reading, building management and energy-monitoring systems. With two inputs and two outputs for pulse, alarm and related functions, up to 25 possible alarms and event logging, the A41 313-100 provides flexible local and networked single-phase energy monitoring.
The ABB A41 313-100 provides direct-connected single-phase measurement up to 80 A, allowing suitable circuits to be monitored without external current transformers. Active and reactive energy can be monitored alongside multiple instrumentation values, while separate import and export registers, a total register and a resettable intermediate register provide flexible visibility of electricity consumption and generation.
Integrated M-Bus communication enables meter information to be transmitted to compatible automatic meter-reading, building management and energy-monitoring systems. Combined with up to four tariffs, two inputs, two outputs, alarm functionality and event logging, the A41 313-100 provides a versatile platform for local and centralised energy monitoring.
Tick the specs you need, then view products that match.
| Measurement Connection Type | CT connection | |
|---|---|---|
| MID Approval | Yes | |
| Current Input Rating (A) | 80 A | |
| Device Type | Energy meter | |
| Series | A41 | |
| Product group | DIN Rail Mounted Meters | |
| ABB order code | 2CMA170504R1000 | |
| EAN | 7392696705042 | |
| Product type | Single-phase electricity / energy meter | |
| Phase configuration | Single phase | |
| Connection type | Direct connected | |
| Rated current | 80 A | |
| Rated voltage (N-L) | 57.7–288 V AC | |
| Rated frequency | 50–60 Hz | |
| Energy measurement | Active and reactive energy | |
| Energy direction | Import and export | |
| Active energy accuracy | Class B MID / IEC Class 1 | |
| Tariffs | Up to 4 | |
| Communication | Wired M-Bus | |
| Inputs | 2 | |
| Outputs | 2 | |
| Input/output functions | Pulse, alarm and related configurable functions | |
| Alarm functionality | Up to 25 possible alarms | |
| Event logging | Yes | |
| Intermediate energy register | Resettable | |
| Display | Backlit pixel-oriented digital display | |
| Power consumption | 0.807 W | |
| Mounting type | DIN rail | |
| Module width | 4 modules | |
| Standard | IEC 62052-11 | |
| Approvals | IEC approved; MID approved and verified |
The ABB A41 313-100 is a single-phase direct-connected energy meter designed to measure active and reactive electrical energy in commercial, industrial, submetering and building energy-management applications.
No. The A41 313-100 is a direct-connected 80 A meter, so external current transformers are not required when the monitored circuit is within its specified direct-connection rating.
The ABB A41 313-100 features integrated wired M-Bus communication, allowing energy and instrumentation data to be accessed by compatible automatic meter-reading, building management and energy-monitoring systems.
Yes. The A41 313-100 measures active and reactive energy and provides separate import and export registers, a total energy register and a resettable intermediate register. It also supports up to four tariffs.
Yes. The A41 313-100 is MID approved and verified and provides Class B active-energy accuracy. It is also IEC approved with Class 1 active-energy accuracy.
ABB A-series DIN-rail energy meters combine accurate electrical measurement, clear local indication and digital communication capabilities, providing a practical platform for submetering, consumption analysis and integration with modern building and industrial energy-management systems.