DM4TA2500 - SPLIT C/TRANSFORMER 2500/5A 80X160MM

DM4TA2500 – SPLIT C/TRANSFORMER 2500/5A 80X160MM

Lovato DM4TA2500 split-core current transformer with a 2500/5 A ratio, an 80 × 160 mm internal opening and Class 0.5 or Class 1 measurement performance.

SKU: DM4TA2500MPN: DM4TA2500
Price
List Price £342.66 ex VAT
Your Price (ex VAT) Save 10%
£308.39 10% OFF
You save £34.27 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £308.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£308.39

Why Choose the Lovato DM4TA2500 Split-Core Current Transformer?

The Lovato DM4TA2500 is a high-capacity split-core current transformer designed for accurate current measurement in industrial switchboards, electrical distribution systems and energy monitoring installations. With a rated primary current of 2500 A and a standard 5 A secondary output, it converts high line currents into a safe and proportional signal for compatible energy meters, network analysers, ammeters and protection equipment.

Unlike a conventional solid-core transformer, the DM4TA2500 features an opening split-core construction that can be installed around an existing conductor or busbar without disconnecting the primary circuit. This makes it particularly useful for retrofit projects, energy-management upgrades and maintenance work where minimising disruption and installation time is important.

The transformer features a generous 80 × 160 mm internal opening for large conductors and busbar assemblies. It provides a rated burden of 15 VA at accuracy class 0.5 and 20 VA at accuracy class 1, delivering reliable measurement performance for demanding high-current applications.

Key Advantages

  • High-capacity 2500/5 A current transformation ratio.
  • Split-core construction permits installation around existing conductors.
  • Large 80 × 160 mm internal opening for substantial busbar systems.
  • Helps reduce installation time by avoiding primary conductor disconnection.
  • Class 0.5 and class 1 accuracy performance for metering and monitoring.
  • Suitable for energy meters, network analysers, ammeters and protection relays.

Key Features

  • Lovato Electric DM series current transformer.
  • Split-core design for convenient retrofit installation.
  • 2500 A rated primary current.
  • 5 A rated secondary current.
  • 50/60 Hz operating frequency.
  • 15 VA burden at accuracy class 0.5.
  • 20 VA burden at accuracy class 1.
  • 120% rated primary-current overload withstand.
  • 80 × 160 mm conductor opening.
  • Secure screw-terminal secondary connections.

Flexible High-Current Measurement for Existing Installations

Current transformers reduce high primary currents to a standard secondary value that can be measured safely by compatible electrical instruments. The Lovato DM4TA2500 converts a primary current of up to 2500 A into a proportional 5 A signal, allowing connected equipment to monitor electrical loads without carrying the full line current.

Its split-core construction allows the transformer to be opened and positioned around an installed conductor or busbar. This provides a practical solution for adding energy monitoring, upgrading an existing metering system or replacing a current transformer where dismantling the primary circuit would be difficult, costly or disruptive.

Typical Applications

  • Retrofit energy-metering installations.
  • High-current industrial switchboards.
  • Electrical distribution and busbar systems.
  • Power quality and energy monitoring equipment.
  • Digital multimeters and network analysers.
  • Current indication and monitoring systems.
  • Protection relay installations.
  • Commercial buildings and manufacturing facilities.

Technical Specifications

Tick the specs you need, then view products that match.

Rated Burden (VA) 15 VA
Device Type Split-core CT
Rated Primary Current (A) 2500 A
Secondary Current / Output 5 A
Current 5 A
Manufacturer Lovato Electric
Series DM
Model DM4TA2500
Product type Split-core current transformer
Primary current 2500 A
Secondary current 5 A
Transformation ratio 2500/5 A
Operating frequency 50/60 Hz
Accuracy class 0.5 burden 15 VA
Accuracy class 1 burden 20 VA
Overload withstand 120% of rated primary current
Rated insulation voltage 720 V AC
Internal opening 80 × 160 mm
Secondary connection Screw terminals
Fixing method Screw fixing
Construction Split core
Dimensions (H × W × D) 245 × 184 × 68 mm
Net weight Approximately 3.02 kg
EAN 8013975187296
Standard IEC/EN 60044-1
HS Code 85389091

Frequently Asked Questions

What is the Lovato DM4TA2500 used for?

The Lovato DM4TA2500 converts high primary currents into a proportional 5 A secondary signal for energy meters, network analysers, ammeters and electrical protection equipment.

What is the current ratio of the DM4TA2500?

The transformer has a current transformation ratio of 2500/5 A, meaning that a 2500 A primary current produces a 5 A secondary output.

Why use a split-core current transformer?

A split-core current transformer can be opened and installed around an existing conductor or busbar without disconnecting the primary circuit, helping simplify retrofit work.

What is the internal opening size?

The DM4TA2500 has an 80 × 160 mm internal opening suitable for large conductors and busbar assemblies.

What accuracy and burden ratings does the transformer provide?

The DM4TA2500 provides 15 VA at accuracy class 0.5 and 20 VA at accuracy class 1.

Trusted for Industrial Energy Measurement