DM4TA2000 - SPLIT C/TRANSFORMER 2000/5A 80X160MM

DM4TA2000 – SPLIT C/TRANSFORMER 2000/5A 80X160MM

Lovato DM4TA2000 split-core current transformer with a 2000/5 A ratio, an 80 × 160 mm internal opening and Class 0.5 or Class 1 measurement performance.

SKU: DM4TA2000MPN: DM4TA2000
Price
List Price £342.66 ex VAT
Your Price (ex VAT) Save 10%
£308.39 10% OFF
You save £34.27 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £308.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£308.39

Why Choose the Lovato DM4TA2000 Split-Core Current Transformer?

The Lovato DM4TA2000 is a high-capacity split-core current transformer designed for accurate current measurement in industrial switchboards, power distribution systems and energy monitoring installations. With a rated primary current of 2000 A and a standard 5 A secondary output, it converts high line currents into a safe and proportional signal for compatible meters, network analysers, ammeters and protection equipment.

Unlike a conventional solid-core transformer, the DM4TA2000 features an opening split-core construction that can be installed around an existing conductor or busbar without disconnecting the primary circuit. This makes it particularly suitable for retrofit projects, system upgrades and maintenance work where minimising installation disruption is important.

The transformer has a generous 80 × 160 mm internal opening for large busbars and conductor assemblies. It provides a rated burden of 15 VA at accuracy class 0.5 and 20 VA at accuracy class 1, supporting dependable metering and electrical monitoring in demanding high-current applications.

Key Advantages

  • High-capacity 2000/5 A current transformation ratio.
  • Split-core construction allows installation around existing conductors.
  • Large 80 × 160 mm internal opening for substantial busbar systems.
  • Reduces installation time and avoids disconnecting the primary conductor.
  • Class 0.5 and class 1 accuracy performance for metering and monitoring.
  • Suitable for energy meters, network analysers, ammeters and protection relays.

Key Features

  • Lovato Electric DM series current transformer.
  • Split-core design for retrofit installation.
  • 2000 A rated primary current.
  • 5 A rated secondary current.
  • 50/60 Hz operating frequency.
  • 15 VA burden at accuracy class 0.5.
  • 20 VA burden at accuracy class 1.
  • 120% rated primary-current overload withstand.
  • 80 × 160 mm conductor opening.
  • Screw terminals and screw fixing for secure installation.

Flexible High-Current Measurement for Existing Installations

Current transformers reduce high primary currents to a standard secondary value that can be safely measured by compatible electrical instruments. The Lovato DM4TA2000 converts a primary current of up to 2000 A into a proportional 5 A signal, enabling accurate load and energy monitoring without carrying the full current through the measuring device.

Its split-core construction allows the transformer to be opened and fitted around an installed conductor or busbar. This provides a practical solution for retrofitting energy monitoring equipment, expanding an existing metering system or replacing a transformer where dismantling the primary circuit would be difficult or disruptive.

Typical Applications

  • Retrofit energy metering installations.
  • High-current industrial switchboards.
  • Electrical distribution and busbar systems.
  • Power quality and energy monitoring equipment.
  • Digital multimeters and network analysers.
  • Current indication and monitoring systems.
  • Protection relay installations.
  • Commercial buildings and manufacturing facilities.

Technical Specifications

Tick the specs you need, then view products that match.

Rated Burden (VA) 15 VA
Rated Primary Current (A) 2000 A
Secondary Current / Output 5 A
Device Type Split-core CT
Current 5 A
Manufacturer Lovato Electric
Series DM
Model DM4TA2000
Product type Split-core current transformer
Primary current 2000 A
Secondary current 5 A
Transformation ratio 2000/5 A
Operating frequency 50/60 Hz
Accuracy class 0.5 burden 15 VA
Accuracy class 1 burden 20 VA
Overload withstand 120% of rated primary current
Rated insulation voltage 720 V AC
Rated short-time thermal current 40 to 60 × Ipn for 1 second
Rated dynamic current 2.5 × Ith
Internal opening 80 × 160 mm
Terminal type Screw terminals
Fixing method Screw fixing
Construction Split core
Approximate dimensions 184 × 68 × 245 mm
Weight Approximately 3160 g
EAN 8013975187289
Applicable standards IEC/EN/BS 61869-1 and IEC/EN/BS 61869-2
HS Code 85389091

Frequently Asked Questions

What is the Lovato DM4TA2000 used for?

The Lovato DM4TA2000 converts a high primary current into a proportional 5 A secondary signal for energy meters, network analysers, ammeters and protection equipment.

What is the current ratio of the DM4TA2000?

The transformer has a current transformation ratio of 2000/5 A, meaning that a 2000 A primary current produces a 5 A secondary output.

Why use a split-core current transformer?

A split-core transformer can be opened and fitted around an existing conductor or busbar without disconnecting it, making installation faster and less disruptive.

What is the internal opening size?

The DM4TA2000 has a large 80 × 160 mm internal opening suitable for substantial conductors and busbar assemblies.

What accuracy and burden ratings does it provide?

The transformer provides 15 VA at accuracy class 0.5 and 20 VA at accuracy class 1.

Trusted for Industrial Energy Measurement