DM1TP0100 Lovato CURRENT TRANSFORMER D28MM 100/5A

DM1TP0100 Lovato CURRENT TRANSFORMER D28MM 100/5A

Lovato DM1TP0100 current transformer with 100/5 A ratio and 28 mm internal diameter for energy monitoring and power measurement applications.

SKU: DM1TP0100
Price
List Price £48.21 ex VAT
Your Price (ex VAT) Save 10%
£43.39 10% OFF
You save £4.82 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £43.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£43.39

Why Choose the Lovato DM1TP0100 Current Transformer?

The Lovato DM1TP0100 is a high-quality current transformer designed for accurate current measurement in electrical monitoring, energy management and power analysis applications. As part of the reliable Lovato DM1T series current transformers, it provides a dependable solution for converting high primary currents into standard secondary signals suitable for measurement devices.

This current transformer features a 100/5 A transformation ratio and a 28 mm internal diameter, making it suitable for installation around compatible cables and conductors in industrial electrical systems. Its robust construction ensures reliable performance in distribution panels, control cabinets and energy monitoring installations.

With accurate current sensing capability and compatibility with Lovato energy meters, power analysers and monitoring equipment, the DM1TP0100 helps improve electrical system visibility, energy analysis and load monitoring performance.

Key Advantages

  • Reliable current transformer for industrial measurement applications.
  • 100/5 A transformation ratio for accurate current monitoring.
  • 28 mm internal diameter suitable for compatible conductors.
  • Provides standard secondary current output for measurement devices.
  • Supports energy monitoring and power analysis applications.
  • Compact design for electrical panel installation.
  • Reliable Lovato construction for long-term operation.

Key Features

  • Lovato DM1T current transformer series.
  • Primary current rating of 100 A.
  • Secondary current output of 5 A.
  • 28 mm through-hole diameter.
  • Designed for connection to energy meters and power analysers.
  • Suitable for industrial electrical monitoring systems.
  • Compact enclosure for switchboard and panel applications.
  • Provides accurate current measurement for energy management.

Reliable Current Measurement for Energy Monitoring Systems

Current transformers such as the Lovato DM1TP0100 allow electrical systems to be monitored by reducing high current levels to standard measurement values compatible with energy meters and analysis equipment. This enables accurate monitoring of loads, consumption and system performance.

The DM1T series is designed for professional electrical installations where dependable measurement accuracy and straightforward integration are required. These transformers are widely used in industrial distribution systems, automation panels and energy management solutions.

Typical Applications

  • Industrial electrical distribution panels.
  • Energy meters and power analysers.
  • Electrical switchboards and control cabinets.
  • Industrial automation systems.
  • Energy management installations.
  • Power monitoring and load analysis applications.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Solid-core CT
Rated Primary Current (A) 100 A
Secondary Current / Output 5 A
Aperture (mm) 28 mm
HS Code 85043180
Manufacturer Lovato
Series DM1T Current Transformers
Model DM1TP0100
Product type Current transformer
Transformation ratio 100/5 A
Primary current 100 A
Secondary current 5 A
Internal diameter 28 mm
Installation type Through-hole conductor mounting
Application Current measurement, energy monitoring and power analysis

Frequently Asked Questions

What is the Lovato DM1TP0100 used for?

The Lovato DM1TP0100 is a current transformer used for measuring electrical current in energy monitoring and power analysis applications.

What is the transformation ratio of the DM1TP0100?

The DM1TP0100 has a 100/5 A transformation ratio.

What is the internal diameter of this current transformer?

The transformer has a 28 mm internal diameter for compatible cable and conductor installation.

What equipment can be connected to this current transformer?

The DM1TP0100 can be connected to compatible energy meters, power analysers and electrical monitoring devices.

Where is the DM1TP0100 typically installed?

The DM1TP0100 is typically installed in electrical panels, switchboards and industrial monitoring systems.

Trusted by Energy Monitoring Professionals

Lovato current transformers are trusted by engineers and system integrators worldwide for accurate measurement, reliable performance and seamless integration into modern electrical monitoring systems.