DM0TW0010 Lovato CURRENT TRANSFORMER 10/5A WOUND PRIMARY

DM0TW0010 Lovato CURRENT TRANSFORMER 10/5A WOUND PRIMARY

Lovato DM0TW0010 is a 10/5 A wound primary current transformer with a standard 5 A secondary output and 3.75 VA burden at Class 0.5 and Class 1 for electrical metering and monitoring applications.

SKU: DM0TW0010
Price
List Price £40.04 ex VAT
Your Price (ex VAT) Save 10%
£36.04 10% OFF
You save £4.00 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £36.04
Trade pricing is personalised to your account

Manufacturer Lead Time

£36.04

Why Choose the Lovato DM0TW0010 10/5 A Wound Primary Current Transformer?

The Lovato DM0TW0010 is a wound primary current transformer designed for accurate current measurement in low-current electrical circuits. With a primary current rating of 10 A and a standard 5 A secondary output, it provides the current transformation required for compatible ammeters, energy meters, power analysers and protection or monitoring equipment.

Unlike a conventional solid-core current transformer where the primary conductor passes through the transformer aperture, the DM0TW0010 uses a wound primary construction. This makes it particularly suitable for lower primary current ratings where a defined 10/5 A transformation ratio is required without arranging multiple conductor turns through a conventional current transformer.

The DM0TW0010 provides an accuracy burden of 3.75 VA for Class 0.5 and 3.75 VA for Class 1. Its standard 5 A secondary makes it suitable for integration with a wide range of compatible Lovato and third-party electrical measuring instruments designed for current transformer inputs.

Key Advantages

  • 10/5 A transformation ratio for low-current measurement applications.
  • Wound primary construction specifically designed for low primary current ratings.
  • Standard 5 A secondary output for compatibility with common metering and monitoring equipment.
  • Class 0.5 measurement capability with a 3.75 VA burden.
  • Suitable for energy meters, power analysers, ammeters and electrical monitoring systems.
  • Purpose-designed Lovato current transformer for industrial and commercial electrical installations.
  • Compact construction suitable for installation inside electrical control and distribution panels.

Key Features

  • Lovato DM0TW series current transformer.
  • Wound primary design.
  • 10 A primary current.
  • 5 A secondary current.
  • 10/5 A transformation ratio.
  • 3.75 VA burden at Class 0.5.
  • 3.75 VA burden at Class 1.
  • Designed for connection to compatible electrical measuring instruments.
  • Suitable for current, power and energy monitoring applications.

Accurate Low-Current Measurement with a Wound Primary CT

A current transformer reduces the current flowing in an electrical circuit to a proportional secondary current that can be safely measured by compatible instrumentation. The 10/5 A ratio of the DM0TW0010 means that a nominal primary current of 10 A corresponds to a 5 A secondary current, allowing suitable measuring equipment to monitor the primary circuit indirectly.

Wound primary current transformers are particularly useful at low primary current ratings because the primary winding is incorporated into the transformer rather than relying on a high-current conductor passing through an aperture. The Lovato DM0TW0010 therefore provides a practical solution for low-current metering, power analysis and electrical monitoring applications requiring a standard 5 A CT secondary.

Typical Applications

  • Low-current electrical measurement.
  • Energy meter current inputs.
  • Power analyser installations.
  • Panel-mounted ammeters and measuring instruments.
  • Industrial electrical distribution panels.
  • Commercial building energy monitoring.
  • Machine and equipment current monitoring.
  • Electrical load and consumption analysis.

Technical Specifications

Tick the specs you need, then view products that match.

Rated Burden (VA) 3.75 VA
Rated Primary Current (A) 10 A
Secondary Current / Output 5 A
Device Type Solid-core CT
HS Code 85043180
Manufacturer Lovato Electric
Family Current Transformers
Series DM0TW
Model DM0TW0010
Product type Current transformer
Construction Wound primary
Primary current 10 A
Secondary current 5 A
Transformation ratio 10/5 A
Class 0.5 burden 3.75 VA
Class 1 burden 3.75 VA
Approximate front dimensions 60 × 76 mm
Application Electrical current measurement and monitoring

Frequently Asked Questions

What is the Lovato DM0TW0010 used for?

The DM0TW0010 is a wound primary current transformer used to convert a primary current of 10 A into a standard 5 A secondary current for compatible electrical measuring and monitoring equipment.

What is the current ratio of the Lovato DM0TW0010?

The DM0TW0010 has a current transformation ratio of 10/5 A, meaning its rated primary current is 10 A and its secondary current is 5 A.

Is the Lovato DM0TW0010 a wound primary current transformer?

Yes. The DM0TW0010 uses a wound primary construction, making it particularly suitable for accurately transforming relatively low primary currents.

What is the accuracy burden of the DM0TW0010?

The DM0TW0010 is rated at 3.75 VA for Class 0.5 and 3.75 VA for Class 1.

What equipment can the Lovato DM0TW0010 be used with?

The DM0TW0010 can be used with compatible energy meters, power analysers, ammeters and other electrical measuring equipment designed to accept a 5 A current transformer secondary input.

Reliable Current Measurement from Lovato Electric

Lovato Electric current transformers provide dependable current transformation for industrial and commercial electrical measurement systems, with the DM0TW wound primary range offering a practical solution for low-current applications requiring a standard 5 A secondary output.