2CSG280825R1000 ABB CT1M-S-120 800 Current Transformer 800 A/5 A

2CSG280825R1000 ABB CT1M-S-120 800 Current Transformer 800 A/5 A

ABB CT1M-S-120 800 2CSG280825R1000 is an 800 A/5 A class 0.5 through-primary current transformer with 7.5 VA class 0.5 output and a 125 × 85 mm vertical busbar opening for indirect electrical metering and monitoring applications.

SKU: 2CSG280825R1000Alt SKU: CT1M-S-120 800MPN: 2CSG280825R1000
Price
List Price £395.76 ex VAT
Your Price (ex VAT)
£395.76
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £395.76
Trade pricing is personalised to your account

Manufacturer Lead Time

£395.76

Why Choose the ABB CT1M-S-120 800 Current Transformer?

The ABB CT1M-S-120 800, order code 2CSG280825R1000, is an 800 A/5 A through-primary current transformer designed for indirect measurement of electrical parameters in metering, monitoring and energy management applications. Part of ABB's Metering Accessories range, it transforms a nominal 800 A primary current into a standardised 5 A secondary current for compatible electricity meters, network analysers and measuring instruments.

As part of the ABB CT1M-S-120 series, the CT1M-S-120 800 provides a large through-primary opening for substantial vertical busbars. ABB's CT1M range is designed according to IEC 61869-2, providing a dedicated solution for transforming primary currents into standard 5 A secondary currents for indirect measurement of electrical network parameters.

With a rated primary current of 800 A, rated secondary current of 5 A and best accuracy class 0.5, the CT1M-S-120 800 provides an 800:5 transformation ratio. It delivers 7.5 VA at class 0.5, 10 VA at class 1 and 12.5 VA at class 3, while its through-primary opening accommodates vertical busbars up to 125 × 85 mm.

Key Advantages

  • Designed for indirect electrical current measurement in metering and monitoring systems.
  • 800 A/5 A current ratio for compatible measuring equipment.
  • Accuracy class 0.5 supports accurate current and energy measurement.
  • 7.5 VA rated output at class 0.5.
  • Large through-primary opening accommodates vertical busbars up to 125 × 85 mm.
  • 50–60 Hz rated frequency for standard AC electrical networks.
  • IP20 protection for installation within suitable electrical enclosures.

Key Features

  • ABB CT1M-S-120 current transformer series.
  • Through-primary construction.
  • 800 A rated primary current.
  • 5 A rated secondary current.
  • 800:5 current transformation ratio.
  • Best accuracy class 0.5.
  • 7.5 VA rated output at class 0.5.
  • 10 VA rated output at class 1.
  • 12.5 VA rated output at class 3.
  • 50–60 Hz rated frequency.
  • IP20 protection rating.
  • Large 125 × 85 mm maximum vertical busbar section.

Accurate Indirect Measurement for Large-Busbar Electrical Systems

Current transformers allow meters and measuring instruments to monitor electrical circuits carrying currents above their direct measurement range. The transformer produces a proportional secondary current, enabling electrical parameters to be measured without routing the full primary circuit current through the connected measuring instrument.

The ABB CT1M-S-120 800 converts a nominal 800 A primary current into a 5 A secondary current. Its class 0.5 accuracy, 7.5 VA class 0.5 output and large 125 × 85 mm vertical busbar opening make it particularly suitable for indirect current measurement in distribution boards, switchboards, power distribution systems and energy management installations using substantial busbar conductors.

Typical Applications

  • Electrical energy metering systems.
  • Commercial and industrial power distribution installations.
  • Main and sub-distribution switchboards.
  • Indirect measurement of circuits with an 800 A nominal current.
  • Energy monitoring and management systems.
  • Current measurement with compatible network analysers, meters and instrumentation.
  • Large vertical busbar current measurement.
  • Industrial panel-building and electrical instrumentation applications.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Panel / base
Rated Primary Current (A) 800 A
Secondary Current / Output 5 A
Accuracy Class Class 0.5
Rated Burden (VA) 7.5 VA
Device Type Solid-core CT
Product group Metering Accessories
Series CT1M-S-120
Order code / Product ID 2CSG280825R1000
Product type Through-primary current transformer
Application Indirect electrical measurement and metering
Rated primary current 800 A
Rated secondary current 5 A
Current ratio 800:5
Best accuracy class 0.5
Rated output, class 0.5 7.5 VA
Rated output, class 1 10 VA
Rated output, class 3 12.5 VA
Rated frequency 50–60 Hz
Protection rating IP20
Construction Through-primary current transformer
Maximum vertical busbar section 125 × 85 mm
Mounting Base mounted with feet
Standard IEC 61869-2
Dimensions (H × W × D) 198 × 155 × 40 mm
Net weight 1.65 kg
EAN / GTIN 8012542808251
Pack unit 1 piece

Frequently Asked Questions

What is the ABB CT1M-S-120 800 2CSG280825R1000 used for?

The CT1M-S-120 800 is a current transformer for indirect electrical measurement, converting a nominal 800 A primary current into a standard 5 A secondary current for compatible meters, network analysers and measuring instruments.

What is the current ratio of the ABB CT1M-S-120 800?

The CT1M-S-120 800 has a rated primary current of 800 A and rated secondary current of 5 A, providing a transformation ratio of 800:5.

What is the accuracy class and rated output of the CT1M-S-120 800?

The ABB CT1M-S-120 800 has a best accuracy class of 0.5 and provides 7.5 VA at class 0.5, 10 VA at class 1 and 12.5 VA at class 3.

What busbar size can the ABB CT1M-S-120 800 accommodate?

The CT1M-S-120 series through-primary opening accommodates vertical busbars up to 125 × 85 mm, making it suitable for substantial conductors in commercial and industrial electrical distribution systems.

Which standard applies to the ABB CT1M-S-120 800?

The ABB CT1M range is designed according to IEC 61869-2 for instrument current transformers used to transform primary currents into standard secondary currents for indirect electrical measurement.

Designed for ABB Electrical Metering and Monitoring Applications

ABB CT1M current transformers provide a dependable solution for converting higher primary currents into standard 5 A secondary signals, supporting accurate indirect electrical measurement in commercial and industrial metering, monitoring and energy management installations.