2CSG280435R1000 ABB CT1M-6 400 Current Transformer 400/5 A

2CSG280435R1000 ABB CT1M-6 400 Current Transformer 400/5 A

ABB CT1M-6 400 2CSG280435R1000 is a class 0.5 through-primary current transformer with a 400 A primary rating, 5 A secondary output and 7.5 VA class 0.5 rated output for indirect electrical metering applications.

SKU: 2CSG280435R1000Alt SKU: CT1M-6 400MPN: 2CSG280435R1000
Price
List Price £74.22 ex VAT
Your Price (ex VAT)
£74.22
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £74.22
Trade pricing is personalised to your account

Manufacturer Lead Time

£74.22

Why Choose the ABB CT1M-6 400 Current Transformer?

The ABB CT1M-6 400 is a reliable 400/5 A current transformer designed for indirect measurement of electrical parameters in low-voltage distribution systems. Supplied under ABB order code 2CSG280435R1000, it forms part of the ABB CT1M current transformer series and is designed in accordance with IEC 61869-2.

With a rated primary current of 400 A and a rated secondary current of 5 A, the CT1M-6 400 converts primary circuit current into a proportional standard secondary signal for compatible electricity meters, ammeters, power analysers and monitoring equipment. Its class 0.5 accuracy and 7.5 VA rated output at class 0.5 support accurate electrical measurement in commercial and industrial installations.

The CT1M-6 400 uses a through-primary design suitable for cables and busbars. Its large primary opening accommodates cables up to 65 mm and horizontal or vertical busbars up to 80 × 10 mm, 60 × 30 mm or 50 × 50 mm. With compact construction, an IP20 degree of protection and a 50–60 Hz rated frequency, it provides a practical solution for higher-current metering installations.

Key Advantages

  • Reliable 400/5 A current transformation for indirect electrical measurement.
  • Class 0.5 accuracy supports precise metering applications.
  • 7.5 VA rated output at accuracy class 0.5.
  • Standard 5 A secondary output for compatible measuring equipment.
  • Large through-primary opening accommodates cables up to 65 mm.
  • Suitable for substantial horizontal and vertical busbars up to 80 × 10 mm, 60 × 30 mm or 50 × 50 mm.
  • FS 5 current limiting factor for metering applications.
  • Busbar and mounting-foot fixings are supplied as standard.
  • Optional DIN-rail installation using the CT1M-4/5/6/7 DIN Rail Adapter.
  • Designed in accordance with IEC 61869-2 for current transformers.

Key Features

  • ABB CT1M-6 current transformer series.
  • 400 A rated primary current.
  • 5 A rated secondary current.
  • 400/5 A transformation ratio.
  • Class 0.5 measurement accuracy.
  • 7.5 VA rated output at class 0.5.
  • 10 VA rated output at class 1.
  • 10 VA rated output at class 3.
  • FS 5 current limiting factor.
  • 50–60 Hz rated frequency.
  • IP20 degree of protection.
  • Through-primary construction for cable and busbar installations.

Reliable Indirect Current Measurement

Current transformers allow electrical meters and monitoring instruments to measure circuits carrying currents above their direct-input range. The ABB CT1M-6 400 transforms a primary current of up to 400 A into a proportional 5 A secondary current, allowing compatible equipment to perform indirect measurement of electrical network parameters.

The CT1M range is designed for current measurement in electrical distribution systems. The CT1M-6 400 combines class 0.5 accuracy with a generous through-primary opening for large cables and busbars, while its standardised 5 A secondary output supports integration with compatible metering and monitoring equipment.

Typical Applications

  • Electrical energy metering systems.
  • Main and sub-distribution switchboards.
  • Low-voltage electrical distribution panels.
  • Power and network monitoring systems.
  • Building energy management installations.
  • Industrial electrical measurement systems.
  • Panel-mounted ammeters and power analysers.
  • Large cable and busbar current measurement applications.

Technical Specifications

Tick the specs you need, then view products that match.

Rated Burden (VA) 7.5 VA
Device Type Solid-core CT
Rated Primary Current (A) 400 A
Secondary Current / Output 5 A
Aperture (mm) 65 mm
Accuracy Class Class 0.5
Series CT1M-6
ABB order code 2CSG280435R1000
Product group Metering Accessories
Product type Current transformer
Rated primary current 400 A
Rated secondary current 5 A
Transformation ratio 400/5 A
Best accuracy class 0.5
Rated output, class 0.5 7.5 VA
Rated output, class 1 10 VA
Rated output, class 3 10 VA
Current limiting factor FS 5
Rated frequency 50–60 Hz
Protection rating IP20
Mounting type Through primary
Conductor arrangement Cable / horizontal or vertical busbar
Maximum cable diameter 65 mm
Busbar sizes 80 × 10 mm / 60 × 30 mm / 50 × 50 mm
DIN-rail mounting Optional with CT1M-4/5/6/7 DIN Rail Adapter
Dimensions (H × W × D) 126 × 104 × 45 mm
Weight 0.64 kg
Standard IEC 61869-2
EAN 8012542804352

Frequently Asked Questions

What is the ABB CT1M-6 400 used for?

The ABB CT1M-6 400 is a current transformer designed to convert primary circuit current into a proportional 5 A secondary current for indirect electrical metering and network measurement.

What is the current ratio of the ABB CT1M-6 400?

The CT1M-6 400 has a rated transformation ratio of 400/5 A, with a 400 A rated primary current and a 5 A rated secondary current.

What accuracy class does the CT1M-6 400 provide?

The ABB CT1M-6 400 provides a best accuracy class of 0.5, with a rated output of 7.5 VA at class 0.5.

What conductor sizes can the CT1M-6 400 accommodate?

The through-primary design accommodates cables up to 65 mm and horizontal or vertical busbars up to 80 × 10 mm, 60 × 30 mm or 50 × 50 mm.

Can the ABB CT1M-6 400 be mounted on a DIN rail?

Yes. DIN-rail mounting is available using the optional CT1M-4/5/6/7 DIN Rail Adapter, while busbar and mounting-foot fixings are supplied as standard.

Trusted ABB Current Measurement Technology

ABB CT1M current transformers provide dependable conversion of primary currents into standard 5 A secondary signals, supporting accurate indirect measurement in commercial, industrial and electrical distribution applications.