SK3311.496 Rittal Refrigerant lines for 65 kW unit L: 20 m : 1/2" and 3/8"

SK3311.496 Rittal Refrigerant lines for 65 kW unit L: 20 m : 1/2″ and 3/8″

Rittal SK 3311.496 is a 20 m insulated refrigerant line set with a 5/8 inch intake gas line and 3/8 inch liquid line for connecting the internal and external units of compatible Rittal LCU DX 6.5 kW cooling systems.

SKU: SK3311.496Alt SKU: 3311496MPN: SK3311.496
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Rittal SK 3311.496 Refrigerant Lines for LCU DX?

The Rittal SK 3311.496 is a purpose-designed 20 m insulated refrigerant line set for Rittal LCU DX 6.5 kW cooling systems. It provides the refrigerant pipework required to connect the internal and external units of a compatible LCU DX installation, supporting reliable circulation of refrigerant through the direct-expansion cooling circuit.

The line set consists of a ⅝″ intake gas line and a ⅜″ liquid line. Both refrigerant lines are insulated, providing a matched connection between the indoor and outdoor sections of the LCU DX system while helping limit unwanted thermal transfer along the refrigerant pipework.

With a generous 20 m length, the SK 3311.496 provides flexibility when positioning and connecting compatible LCU DX equipment. Designed specifically for the 6.5 kW LCU DX system, it offers correctly sized refrigerant lines in a complete Rittal accessory set for professional data centre and IT cooling installations.

Key Advantages

  • Purpose-designed refrigerant line set for Rittal LCU DX 6.5 kW cooling systems.
  • Provides the required refrigerant connection between compatible internal and external LCU DX units.
  • Generous 20 m length provides flexibility when positioning cooling equipment.
  • Includes a correctly sized ⅝″ intake gas line and ⅜″ liquid line.
  • Insulated refrigerant lines help limit unwanted heat transfer along the pipework.
  • Genuine Rittal accessory designed as a matched solution for compatible LCU DX installations.

Key Features

  • Rittal SK refrigerant line set.
  • Designed specifically for LCU DX 6.5 kW.
  • 20 m line length.
  • ⅝″ intake gas line.
  • ⅜″ liquid line.
  • Both refrigerant lines are insulated.
  • Connects the internal and external units of the LCU DX cooling system.
  • Matched pipe sizes for the specified 6.5 kW LCU DX application.
  • Supplied as one complete refrigerant line set.

Reliable Refrigerant Connections for LCU DX Cooling

Direct-expansion cooling relies on correctly specified refrigerant pipework to transport refrigerant between the internal and external sections of the refrigeration system. Appropriate pipe sizing and insulation are important for maintaining the intended operating characteristics of the cooling circuit.

The Rittal SK 3311.496 provides the specified ⅝″ intake gas line and ⅜″ liquid line for compatible 6.5 kW LCU DX systems. Its 20 m insulated construction provides installation flexibility while delivering a matched Rittal connection solution for the internal and external cooling units.

Typical Applications

  • Rittal LCU DX 6.5 kW cooling systems.
  • Connection of compatible LCU DX internal and external units.
  • Data centre direct-expansion cooling installations.
  • Server and network infrastructure cooling.
  • IT equipment rooms requiring dedicated DX cooling.
  • Installation or replacement of compatible Rittal LCU DX refrigerant pipework.

Technical Specifications

Manufacturer Rittal
Series SK
Model SK 3311.496
Product type Refrigerant lines
Application Rittal LCU DX
Compatible cooling capacity 6.5 kW
Function Connection between internal and external LCU DX units
Length 20 m
Intake gas line diameter ⅝″
Liquid line diameter ⅜″
Line construction Insulated
Supply includes Intake gas line and liquid line
Pack quantity 1 pc
Net weight 14.5 kg
Gross weight 16 kg
Customs tariff number 39173900
ETIM 9 classification EC000855
ETIM 8 classification EC000855
ECLASS 8.0 27180704

Frequently Asked Questions

What is the Rittal SK 3311.496 used for?

The SK 3311.496 is an insulated refrigerant line set for connecting the internal and external units of a Rittal LCU DX 6.5 kW cooling system.

How long are the Rittal SK 3311.496 refrigerant lines?

The refrigerant line set has a length of 20 m, providing flexibility when routing pipework between compatible internal and external LCU DX units.

What pipe sizes are included with the Rittal SK 3311.496?

The set includes a ⅝″ intake gas line and a ⅜″ liquid line.

Are the Rittal SK 3311.496 refrigerant lines insulated?

Yes. Both refrigerant lines in the SK 3311.496 set are insulated for use between the internal and external units of the compatible LCU DX system.

Which cooling unit is the Rittal SK 3311.496 designed for?

The SK 3311.496 is specifically designed for the Rittal LCU DX 6.5 kW cooling system.

Trusted Data Centre Climate Control from Rittal

Rittal LCU DX accessories support reliable direct-expansion cooling for IT infrastructure, with the SK 3311.496 providing a purpose-designed 20 m insulated refrigerant connection for compatible 6.5 kW LCU DX internal and external units.