Finder 7F.30.9.024.3100 is a Size 3 outdoor electrical enclosure filter fan operating from 24 V DC with 100 m³/h free-air flow, 75 m³/h filtered airflow, 7 W rated power, IP54 protection and IK08 impact resistance for industrial cabinet cooling.
£67.33
The Finder 7F.30.9.024.3100 is a Size 3 outdoor electrical enclosure filter fan designed to provide dependable forced-air ventilation for industrial electrical cabinets, control panels and automation equipment. Part of the Finder 7F Series, this standard-flow fan is engineered for outdoor applications where effective cooling and resistance to environmental conditions are essential.
Operating from a 24 V DC supply, the fan delivers a nominal 100 m³/h free-air flow rate and approximately 75 m³/h airflow with a compatible exhaust filter installed. Its low 7 W rated power consumption makes it suitable for electrical enclosures supplied by industrial DC control systems.
With IP54 ingress protection, IK08 impact resistance, a weather-resistant housing and a replaceable G3 synthetic fibre filter mat, the Finder 7F.30.9.024.3100 provides a practical ventilation solution for outdoor switchgear, industrial automation cabinets and infrastructure equipment. Its compact 209 × 209 mm front dimensions and push-in terminals simplify installation and maintenance.
The Finder 7F.30.9.024.3100 is designed to support temperature control in electrical enclosures containing heat-generating equipment such as PLCs, power supplies, contactors, motor controllers and electronic automation devices. Its powered fan draws ambient air through the filter assembly, helping establish airflow through the cabinet and dissipate accumulated heat.
With a nominal free-air capacity of 100 m³/h, the fan provides approximately 75 m³/h when used with a compatible exhaust filter under the manufacturer's stated test conditions. Actual airflow depends on enclosure resistance, filter condition and installation arrangement. The fan should be selected according to the cabinet heat load and surrounding ambient temperature.
The 7F.30 outdoor construction incorporates protection features suitable for demanding installations, including IP54 ingress protection, IK08 impact resistance and an operating temperature range extending down to −30 °C. Its replaceable G3 filter mat and convenient push-in electrical terminals help simplify servicing while maintaining reliable enclosure ventilation.
Tick the specs you need, then view products that match.
| Cut-Out Size (mm) | 177 × 177 mm | |
|---|---|---|
| Manufacturer | Finder | |
| Series | 7F Series | |
| Model | 7F.30.9.024.3100 | |
| Product type | Outdoor electrical enclosure filter fan | |
| Fan configuration | Standard flow / filtered-air intake | |
| Size | 3 | |
| Rated supply voltage | 24 V DC | |
| Operating voltage range | 19.2–26.4 V DC | |
| Free-air flow rate | 100 m³/h | |
| Airflow with exhaust filter installed | 75 m³/h | |
| Rated power | 7 W | |
| Current consumption | 0.32 A | |
| Noise level | 45 dB(A) | |
| Nominal service life | 50,000 hours at 40 °C | |
| Protection rating | IP54 | |
| Impact resistance | IK08 | |
| NEMA classification | Type 12 / Type 3R | |
| Filter classification | G3 according to EN 779 | |
| Filter efficiency | 80–90% according to EN 779 G3 classification | |
| ISO 16890 classification | ISO coarse 55% | |
| Filter material | Synthetic fibre with progressive filtration structure | |
| Filter temperature resistance | Up to +100 °C | |
| Filter flame behaviour | Self-extinguishing, Class F1 according to DIN 53438 | |
| Housing material | Flame-retardant plastic, UL94 V-0 | |
| Ambient operating temperature | −30 to +55 °C | |
| Front dimensions (H × W) | 209 × 209 mm | |
| Installation depth | 71.2 mm | |
| Fan bearing type | Ball bearing | |
| Mounting type | Electrical enclosure wall mounting | |
| Electrical connection | Push-in terminals | |
| Conductor cross-section | 0.7–2.5 mm² | |
| Compatible ventilation accessories | Finder 7F Series Size 3 exhaust filters | |
| Manufacturer part number | 7F.30.9.024.3100 |
The Finder 7F.30.9.024.3100 is a Size 3 outdoor filter fan designed to provide forced-air ventilation and cooling for industrial electrical cabinets, switchboards and automation enclosures.
The fan provides a nominal 100 m³/h free-air flow rate. When installed with a compatible exhaust filter, the rated airflow is approximately 75 m³/h under specified test conditions.
The filter fan operates from a 24 V DC supply, with a nominal power consumption of 7 W and a current consumption of approximately 0.32 A.
Yes. The filter fan belongs to the Finder 7F.30 outdoor range and features IP54 ingress protection, IK08 impact resistance and an ambient operating temperature range of −30 to +55 °C.
The Size 3 filter fan has front dimensions of 209 × 209 mm and an installation depth of approximately 71.2 mm. Electrical wiring is connected through push-in terminals.
Finder 7F Series filter fans provide dependable ventilation solutions for industrial electrical cabinets and automation equipment. The 7F.30.9.024.3100 combines 24 V DC operation, 100 m³/h nominal airflow, low 7 W power consumption, IP54 protection and IK08 impact resistance to support efficient outdoor electrical enclosure thermal management.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.