Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 7F.30.9.024.2055 is a Size 2 outdoor filter fan for electrical cabinets featuring a 24 V DC supply, 55 m³/h free-air airflow, 40 m³/h filtered airflow, 7 W rated power, IP54 ingress protection, IK08 impact resistance and UL Type 3R outdoor enclosure protection.
£50.95
The Finder 7F.30.9.024.2055 is a compact, weather-resistant 24 V DC outdoor filter fan designed to provide reliable ventilation for electrical cabinets, industrial automation panels and outdoor control enclosures. Part of the Finder 7F Series, this Size 2 industrial enclosure cooling fan delivers a nominal 55 m³/h free-air airflow while consuming just 7 W of electrical power.
Designed specifically for outdoor electrical enclosure ventilation, the Finder 7F.30.9.024.2055 combines a robust dark grey housing, IP54 ingress protection, IK08 impact resistance and UL Type 3R environmental protection. Its construction supports installations exposed to changing weather conditions, including rain, frost and ultraviolet radiation, when correctly installed in accordance with the manufacturer's instructions.
Unlike reverse flow exhaust fans, the Finder 7F.30 standard draw-in configuration introduces filtered ambient air into the electrical enclosure. This incoming air helps displace warm air generated by industrial power supplies, PLCs, communication equipment, contactors and other electrical components. When paired with a suitable exhaust filter, the fan provides approximately 40 m³/h of filtered airflow, supporting effective thermal management in compact and medium-sized outdoor electrical cabinets.
Featuring a 155 × 155 mm front grille, a 24 V DC supply, a replaceable G3 filter mat and time-saving snap-in mounting, the Finder 7F.30.9.024.2055 is an excellent choice for electrical engineers, industrial panel builders, OEM machine manufacturers and maintenance professionals requiring a dependable outdoor cabinet ventilation solution.
The Finder 7F.30.9.024.2055 is designed to provide effective airflow in electrical enclosures installed in outdoor and exposed industrial environments. These installations often experience significant changes in ambient temperature, humidity and weather conditions, making ventilation system selection particularly important.
Outdoor electrical cabinets may contain equipment such as industrial controllers, power supplies, communication devices, telemetry systems, motor control components and electrical distribution equipment. These devices generate heat during normal operation, potentially increasing the temperature inside the enclosure.
The Finder 7F.30.9.024.2055 addresses this challenge by introducing filtered ambient air into the cabinet. The incoming air can help carry heat away from installed equipment before exiting through a corresponding exhaust filter or ventilation opening.
Its 55 m³/h nominal free-air capacity provides a useful balance between airflow performance and compact construction, making it suitable for medium-sized electrical enclosures where larger ventilation systems may be unnecessary.
The outdoor-oriented design is particularly valuable where the electrical cabinet is exposed to rain, frost, airborne dust or sunlight. The fan's IP54, IK08 and UL Type 3R characteristics support appropriately designed outdoor enclosure installations.
The Finder 7F.30.9.024.2055 delivers a nominal 55 m³/h free-air airflow, equivalent to approximately 32.4 CFM. This is the fan's specified airflow under low-resistance conditions.
When a corresponding exhaust filter is included in the enclosure ventilation arrangement, the specified airflow is approximately 40 m³/h, equivalent to around 23.5 CFM.
This distinction is important because actual installed airflow is affected by the resistance created by filters, ventilation openings, internal components and cabinet construction.
For effective cooling, the air inlet and exhaust outlet should be positioned to encourage circulation across heat-generating equipment. A typical arrangement places the filtered intake fan lower in the enclosure and the exhaust filter higher up, although the final layout should be determined by the cabinet design and manufacturer guidance.
Cabinet cooling requirements should be calculated using the total heat dissipated by the installed equipment, the maximum permissible internal temperature and the surrounding ambient temperature.
Forced-air ventilation cannot cool an enclosure below the temperature of the incoming ambient air. If ambient conditions are unsuitable, an enclosure air conditioner or another cooling solution may be required.
The Finder 7F.30.9.024.2055 operates from a nominal 24 V DC supply, making it suitable for industrial automation systems that already use low-voltage DC power distribution.
Its specified operating voltage range is 19.2–26.4 V DC, corresponding to 80–110% of the nominal supply voltage.
With a 7 W rated power consumption and a nominal current draw of 0.32 A, the fan can be incorporated into a suitable DC power system without requiring a separate AC supply.
This is particularly useful for outdoor automation cabinets containing PLCs, remote I/O modules, communication equipment and other devices powered by a common 24 V DC supply.
The fan may also be controlled using a suitable thermostat or switching device. Temperature-controlled operation can reduce unnecessary running time while providing ventilation when the internal cabinet temperature rises.
The Finder 7F.30.9.024.2055 is a DC-powered fan. It must not be connected directly to an AC supply. The power source, wiring and switching devices should be selected according to the manufacturer's electrical requirements.
The Finder 7F.30.9.024.2055 is designed for outdoor electrical cabinet ventilation and incorporates several environmental protection characteristics.
Its IP54 rating provides protection against harmful dust ingress and splashing water. This helps support the protection of electrical equipment installed within appropriately designed enclosures.
The IK08 impact resistance rating provides additional mechanical protection, making the fan suitable for industrial installations where accidental impacts may occur.
The UL Type 3R classification supports use in suitable indoor and outdoor electrical enclosures. The housing design is intended for outdoor applications where exposure to rain, frost and ultraviolet radiation must be considered.
The dark grey RAL 7000 housing provides a practical industrial finish and complements a wide range of outdoor electrical cabinet designs.
These protection ratings depend on correct installation. The fan should be mounted in the orientation specified by Finder, and the complete enclosure must be assessed for its intended environmental conditions.
For aggressive environments involving corrosive chemicals, marine exposure or high-pressure cleaning, additional protection may be required.
The Finder 7F.30.9.024.2055 incorporates a replaceable G3 filter mat according to EN 779. The filter helps capture airborne particles before they enter the electrical enclosure.
The filter material uses progressive synthetic fibre construction with a specified filtration degree of approximately 80–90% under the manufacturer's test conditions.
The material is temperature-resistant up to +100 °C and is classified as self-extinguishing according to Class F1 of DIN 53438.
As dust accumulates, airflow resistance increases and cooling performance can decrease. Regular inspection and replacement are therefore important for maintaining effective cabinet ventilation.
The fan's construction allows the filter mat to be accessed and replaced as part of routine maintenance, helping reduce servicing time.
Replacement filter media should be selected according to Finder's current Size 2 accessory documentation to maintain the intended fit, filtration characteristics and enclosure protection.
The Finder 7F.30.9.024.2055 uses a Size 2 mounting format with a front grille measuring approximately 155 × 155 mm.
The fan is designed for a nominal 125 × 125 mm enclosure cut-out. The exact cutting dimensions, tolerances and permitted panel thickness should be checked against the manufacturer's current dimensional drawing before installation.
The snap-in mounting arrangement helps simplify installation into a correctly prepared panel opening, reducing the need for additional fixing hardware.
Electrical connection is provided through push-in terminals, suitable for conductor sizes from 0.7 to 2.5 mm² (AWG 18–14).
The fan should be installed in the correct orientation for its standard draw-in airflow configuration. A suitable exhaust filter should be selected to complete the enclosure ventilation system.
For outdoor applications, the enclosure design must also account for water drainage, condensation, cable entry protection and the protection ratings of all installed components.
The Finder 7F.30.9.024.2055 has a specified acoustic noise level of 46 dB(A), making it suitable for industrial electrical cabinets where relatively quiet ventilation is desirable.
Its nominal service life of 50,000 hours at 40 °C provides a useful reference for maintenance planning, although actual operating life depends on ambient temperature, environmental conditions and maintenance.
The specified operating temperature range of −30 to +55 °C supports a broad range of outdoor installations, provided the other equipment inside the enclosure is also suitable for those conditions.
The combination of low power consumption, compact construction, outdoor environmental protection and straightforward filter maintenance makes the Finder 7F.30.9.024.2055 a practical solution for long-term industrial cabinet ventilation.
Tick the specs you need, then view products that match.
| Cut-Out Size (mm) | 125 × 125 mm | |
|---|---|---|
| Manufacturer | Finder | |
| Series | 7F Series | |
| Model | 7F.30.9.024.2055 | |
| Product type | Outdoor enclosure filter fan | |
| Fan configuration | Standard flow / draw-in | |
| Airflow direction | From outside the enclosure to the inside | |
| Primary function | Filtered air intake for electrical enclosure ventilation | |
| Nominal supply voltage | 24 V DC | |
| Supply type | Direct current | |
| Operating voltage range | 19.2–26.4 V DC | |
| Operating voltage tolerance | 0.8–1.1 × nominal voltage | |
| Nominal current consumption | 0.32 A | |
| Rated power consumption | 7 W | |
| Nominal free-air airflow | 55 m³/h | |
| Airflow with corresponding exhaust filter | 40 m³/h | |
| Approximate free-air airflow | 32.4 CFM | |
| Approximate filtered airflow | 23.5 CFM | |
| Fan size | Size 2 | |
| Nominal size class | 6-inch | |
| Front grille width | 155 mm | |
| Front grille height | 155 mm | |
| Nominal enclosure cut-out | 125 × 125 mm | |
| Noise level | 46 dB(A) | |
| Nominal fan service life | 50,000 hours at 40 °C | |
| Operating ambient temperature | −30 to +55 °C | |
| Ingress protection | IP54 | |
| Mechanical impact resistance | IK08 | |
| Outdoor enclosure classification | UL Type 3R | |
| Housing colour | Dark grey | |
| RAL colour reference | RAL 7000 | |
| Housing material | Flame-retardant plastic | |
| Housing flammability classification | UL94 V-0 | |
| Filter mat | Included and replaceable | |
| Filter classification | G3 according to EN 779 | |
| Nominal filtration degree | 80–90% under specified test conditions | |
| Filter material | Synthetic fibre with progressive construction | |
| Filter temperature resistance | Up to +100 °C | |
| Filter flame classification | Self-extinguishing, Class F1 according to DIN 53438 | |
| Electrical connection | Push-in terminals | |
| Conductor cross-section | 0.7–2.5 mm² | |
| Conductor size | AWG 18–14 | |
| Mounting method | Snap-in panel mounting | |
| Installation environment | Indoor and outdoor electrical enclosures | |
| Weather resistance | Designed for suitable exposure to rain, frost and UV radiation | |
| Country of manufacture | Italy | |
| Corresponding indoor version | Finder 7F.20.9.024.2055 | |
| Corresponding outdoor reverse flow version | Finder 7F.31.9.024.2055 |
The Finder 7F.30.9.024.2055 is a 24 V DC outdoor filter fan designed to provide filtered ventilation for electrical cabinets and industrial control enclosures. It draws ambient air into the enclosure to help remove heat generated by electrical equipment.
Yes. The Finder 7F.30 Series is designed for outdoor electrical enclosure ventilation. This model features IP54 ingress protection, IK08 impact resistance and a UL Type 3R outdoor enclosure classification when correctly installed.
The fan operates from a nominal 24 V DC supply, with a specified operating range of 19.2–26.4 V DC. It must not be connected directly to an AC supply.
The fan provides a nominal free-air airflow of 55 m³/h. With a corresponding exhaust filter installed, the specified airflow is approximately 40 m³/h.
The Finder 7F.30.9.024.2055 is a standard flow / draw-in filter fan. It draws ambient air into the electrical enclosure. For outdoor applications requiring reverse flow exhaust operation, the corresponding Finder 7F.31 Series should be considered.
The fan has a rated power consumption of 7 W and draws approximately 0.32 A at its nominal 24 V DC supply.
The fan has an IP54 ingress protection rating when correctly installed. It also features IK08 impact resistance and is specified for suitable UL Type 3R outdoor enclosure applications.
The fan uses the Finder Size 2 mounting format and has a front grille measuring approximately 155 × 155 mm.
The fan is designed for a nominal 125 × 125 mm enclosure cut-out. The manufacturer's Size 2 installation drawing should be consulted for exact tolerances and mounting requirements.
The fan has a specified acoustic noise level of 46 dB(A), providing relatively quiet ventilation for industrial electrical enclosures.
Yes. The fan includes a replaceable G3 filter mat. Replacement media should be selected according to Finder's current Size 2 accessory documentation.
The fan is specified for an operating ambient temperature range of −30 to +55 °C, making it suitable for a broad range of outdoor industrial installations.
Both models are 24 V DC Size 2 standard flow filter fans with a nominal 55 m³/h free-air rating and 7 W power consumption. The key difference is the intended environment: the 7F.30.9.024.2055 is designed for outdoor use, while the 7F.20.9.024.2055 is the indoor version.
Both models are 24 V DC Size 2 outdoor filter fans. The main difference is airflow direction: the 7F.30.9.024.2055 is the standard draw-in version, while the 7F.31.9.024.2055 is the reverse flow exhaust version.
The Finder 7F.30.9.024.2055 combines Size 2 construction, 24 V DC operation, 55 m³/h nominal free-air capacity, 40 m³/h filtered airflow, low 7 W power consumption, IP54 ingress protection, IK08 impact resistance and UL Type 3R outdoor protection. Its replaceable G3 filter mat, low acoustic noise and snap-in mounting design make it a practical choice for electrical engineers, industrial panel builders, automation specialists and maintenance professionals working with outdoor electrical cabinets.
Manufacturer technical reference: Finder 7F Series Filter Fans – Official Technical Datasheet. Installation dimensions, electrical ratings and environmental protection requirements should be checked against the current manufacturer documentation before installation.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.