Finder 7F.30.9.024.1020 is a Size 1 outdoor filter fan for electrical cabinets featuring a 24 V DC supply, 24 m³/h free-air airflow, 14 m³/h filtered airflow, 3.6 W rated power, IP54 ingress protection, IK08 impact resistance and compact 120 × 120 mm construction.
£46.13
The Finder 7F.30.9.024.1020 is a compact, weather-resistant 24 V DC outdoor enclosure filter fan designed to provide effective ventilation for electrical cabinets, industrial automation panels and outdoor control enclosures. Part of the Finder 7F Series, this Size 1 filter fan combines a nominal 24 m³/h free-air airflow, low power consumption and robust environmental protection in a compact assembly.
Unlike standard indoor filter fans, the Finder 7F.30 Series is specifically designed for outdoor electrical enclosure ventilation. Its construction is intended to withstand challenging environmental conditions, including exposure to rain, frost and ultraviolet radiation, when installed in accordance with the manufacturer's instructions. The fan features IP54 ingress protection, IK08 impact resistance and an outdoor-oriented enclosure design.
Operating from a nominal 24 V DC supply, the Finder 7F.30.9.024.1020 consumes just 3.6 W and draws approximately 150 mA. Its 120 × 120 mm front grille, shallow installation depth and easily replaceable filter mat make it an excellent solution for compact industrial cabinets where reliable cooling, straightforward installation and efficient maintenance are important.
The Finder 7F.30.9.024.1020 is designed for electrical cabinets installed in environments where conventional indoor filter fans may not provide suitable environmental protection. Outdoor electrical enclosures are commonly exposed to changing temperatures, rain, airborne dust, frost and ultraviolet radiation, all of which must be considered when selecting ventilation equipment.
The Finder 7F.30 Series addresses these requirements through an outdoor-oriented filter fan design. The assembly provides IP54 protection, IK08 impact resistance and a UL Type 3R enclosure classification when installed as specified.
Its standard airflow configuration draws ambient air into the electrical enclosure through the filter fan assembly. The incoming air can help remove heat from electrical components before exiting through a suitable exhaust opening or complementary outlet filter.
This airflow arrangement is particularly useful in compact outdoor control cabinets containing industrial power supplies, communication equipment, controllers and other components that generate moderate amounts of heat.
For effective operation, the ventilation system should be designed so that air passes through the areas where cooling is required. The exhaust opening should be positioned to reduce the risk of incoming air travelling directly to the outlet without circulating through the cabinet.
The Finder 7F.30.9.024.1020 provides a nominal 24 m³/h free-air airflow, equivalent to approximately 14.1 CFM. This makes it suitable for smaller electrical cabinets where a compact ventilation solution is required.
When a corresponding exhaust filter is included in the ventilation arrangement, the specified airflow is approximately 14 m³/h, equivalent to around 8.2 CFM.
The difference between free-air and filtered airflow is important because it demonstrates the effect of resistance within the ventilation system. Filters, grille openings, cabinet construction and internal equipment can all reduce the volume of air delivered through an installed enclosure.
Electrical cabinet cooling requirements should therefore be calculated using the total heat dissipated by the equipment, the maximum permitted internal temperature and the surrounding ambient conditions.
Forced-air ventilation cannot cool an enclosure below the temperature of the incoming ambient air. Where the outdoor temperature is too high, or where contaminants must be completely excluded, an enclosure cooling solution that does not exchange ambient air may be more appropriate.
The Finder 7F.30.9.024.1020 operates from a nominal 24 V DC supply, making it suitable for electrical control systems that already use 24 V DC power distribution.
With a rated power consumption of only 3.6 W and a nominal current draw of 150 mA, the fan places a relatively small continuous load on the control system's DC power supply.
This can be advantageous in compact outdoor electrical cabinets where power supply capacity and available installation space are limited.
The fan can also be incorporated into a temperature-controlled ventilation arrangement using a suitable thermostat or controller. In such applications, the fan can be switched on when the internal cabinet temperature exceeds a selected threshold.
Any switching device must be suitable for the fan's DC electrical load, and the installation must follow the manufacturer's wiring and protection requirements.
The Finder 7F.30.9.024.1020 is a DC-powered fan. It must not be connected directly to an AC supply. Where an AC-powered outdoor filter fan is required, an appropriately rated Finder 7F.30 Series AC version should be selected.
The Finder 7F.30.9.024.1020 is designed for outdoor electrical enclosures and incorporates several important environmental protection characteristics.
Its IP54 rating provides protection against harmful dust ingress and water splashing from different directions. This makes the fan suitable for appropriately designed electrical cabinets where filtered ventilation and resistance to environmental exposure are required.
The IK08 impact resistance rating provides additional protection against mechanical impacts that may occur during installation, maintenance or normal industrial use.
The fan is also specified for UL Type 3R applications, supporting suitable indoor and outdoor electrical enclosures. The outdoor-oriented housing design is intended to accommodate exposure to rain, frost and UV radiation within the manufacturer's specified operating conditions.
These ratings do not mean that the fan is waterproof under all conditions. Correct installation orientation, panel sealing, maintenance and the protection rating of the complete enclosure remain essential.
For particularly aggressive environments, including marine exposure, corrosive atmospheres or high-pressure washdown, the suitability of the complete enclosure ventilation system should be assessed separately.
The Finder 7F.30.9.024.1020 includes an easily replaceable filter mat designed to help manage airborne contaminants entering the electrical enclosure.
During operation, the filter captures particles carried by the incoming airflow. Over time, accumulated dust can increase resistance and reduce the amount of air entering the cabinet.
Routine filter inspection and replacement are therefore important for maintaining ventilation performance. Maintenance intervals should be based on the surrounding environment and the level of airborne contamination.
The fan's construction allows the filter mat to be accessed and replaced without unnecessary dismantling of the electrical cabinet. This is particularly useful for outdoor installations where maintenance time may be limited.
Replacement filter media should be selected according to the current Finder Size 1 accessory documentation to ensure the correct dimensions, filtration characteristics and environmental protection.
The Finder 7F.30.9.024.1020 features a compact 120 × 120 mm front grille, making it suitable for small electrical cabinets and outdoor control enclosures.
The assembly has an overall depth of approximately 51 mm, with an installation depth of approximately 41.4 mm. This shallow construction helps conserve valuable space inside the electrical cabinet.
The fan is designed for a nominal 92 × 92 mm panel cut-out. Installers should consult the current Finder mounting drawing before cutting the enclosure to confirm the exact dimensions, tolerances and permitted panel thickness.
The snap-in mounting system helps reduce installation time and allows the fan to be fitted into a correctly prepared panel opening without a complex fixing arrangement.
Electrical connection is provided through push-in terminals, supporting efficient wiring during panel assembly and maintenance.
The fan should be installed in the correct orientation for its standard draw-in airflow configuration and outdoor protection requirements. The associated exhaust opening must also be suitable for the intended environmental conditions.
The Finder 7F.30.9.024.1020 features a ball-bearing fan motor designed for reliable industrial operation.
Its nominal acoustic noise level of 37.5 dB(A) makes it a relatively quiet enclosure ventilation solution, particularly when compared with larger, high-airflow industrial fans.
The fan has a specified nominal service life of 50,000 hours at 40 °C. Actual service life depends on ambient temperature, operating conditions, maintenance and environmental exposure.
Its operating temperature range of −30 to +55 °C supports a broad range of outdoor industrial applications, provided the electrical enclosure and other installed components are suitable for the same conditions.
The combination of low power consumption, compact construction, outdoor protection and straightforward maintenance makes the Finder 7F.30.9.024.1020 a practical choice for reliable electrical enclosure ventilation.
Tick the specs you need, then view products that match.
| Cut-Out Size (mm) | 92 × 92 mm | |
|---|---|---|
| Manufacturer | Finder | |
| Series | 7F Series | |
| Product code | 7F.30.9.024.1020 | |
| Product type | Outdoor enclosure filter fan | |
| Fan configuration | Standard flow / draw-in | |
| Primary function | Filtered air intake for electrical enclosure ventilation | |
| Intended installation | Indoor and outdoor electrical enclosures | |
| Nominal supply voltage | 24 V DC | |
| Supply type | Direct current | |
| Nominal current consumption | 0.15 A | |
| Rated power consumption | 3.6 W | |
| Free-air airflow | 24 m³/h | |
| Filtered airflow with corresponding exhaust filter | 14 m³/h | |
| Approximate free-air airflow | 14.1 CFM | |
| Approximate filtered airflow | 8.2 CFM | |
| Fan size | Size 1 | |
| Front grille width | 120 mm | |
| Front grille height | 120 mm | |
| Overall assembly depth | Approximately 51 mm | |
| Installation depth | 41.4 mm | |
| Nominal mounting cut-out | 92 × 92 mm | |
| Noise level | 37.5 dB(A) | |
| Bearing type | Ball bearing | |
| Nominal service life | 50,000 hours at 40 °C | |
| Operating ambient temperature | −30 to +55 °C | |
| Ingress protection | IP54 | |
| Mechanical impact resistance | IK08 | |
| Outdoor enclosure classification | UL Type 3R | |
| Housing colour | Dark grey | |
| Housing colour reference | RAL 7000 | |
| Housing material | Flame-retardant plastic | |
| Flammability classification | UL94 V-0 | |
| Filter arrangement | Replaceable filter mat | |
| Mounting method | Snap-in panel mounting | |
| Electrical connection | Push-in terminals | |
| Typical conductor sizes | AWG 18–14 | |
| Installation environment | Suitable outdoor electrical enclosure applications | |
| Weather resistance | Designed for exposure to rain, frost and UV radiation within specified operating limits | |
| Compliance | CE, UKCA and RoHS | |
| Country of origin | Italy | |
| Corresponding indoor version | Finder 7F.20.9.024.1020 | |
| Corresponding outdoor reverse flow version | Finder 7F.31.9.024.1020 |
The Finder 7F.30.9.024.1020 is a 24 V DC outdoor filter fan designed to provide filtered ventilation for electrical cabinets and industrial control enclosures. It draws ambient air into the enclosure to help remove heat generated by electrical equipment.
Yes. The Finder 7F.30 Series is specifically designed for outdoor electrical enclosure ventilation. This model features IP54 ingress protection, IK08 impact resistance and a UL Type 3R outdoor enclosure classification when correctly installed.
The fan operates from a nominal 24 V DC supply. It draws approximately 150 mA and has a rated power consumption of 3.6 W.
The fan provides a nominal free-air airflow of 24 m³/h. With a corresponding exhaust filter installed, the specified airflow is approximately 14 m³/h.
The Finder 7F.30.9.024.1020 is a standard flow / draw-in filter fan. It draws ambient air into the electrical enclosure. For outdoor applications requiring reverse flow exhaust operation, the corresponding Finder 7F.31 Series should be considered.
The fan has an IP54 ingress protection rating when correctly installed. It also features IK08 impact resistance and is specified for suitable UL Type 3R outdoor enclosure applications.
The fan has a 120 × 120 mm front grille, an overall depth of approximately 51 mm and an installation depth of approximately 41.4 mm.
The fan uses a nominal 92 × 92 mm mounting cut-out. The current Finder Size 1 installation drawing should be consulted for exact tolerances and mounting requirements.
The fan has a rated power consumption of 3.6 W and draws approximately 0.15 A at its nominal 24 V DC supply.
The fan has a specified acoustic noise level of 37.5 dB(A), making it suitable for applications where relatively quiet enclosure ventilation is desirable.
Yes. The fan includes an easily replaceable filter mat. Replacement media should be selected according to Finder's current Size 1 accessory documentation.
The fan is specified for an operating ambient temperature range of −30 to +55 °C, making it suitable for a broad range of outdoor industrial installations.
Both models are 24 V DC Size 1 standard flow filter fans with a nominal 24 m³/h free-air rating and 3.6 W power consumption. The main difference is the intended environment: the 7F.30.9.024.1020 is designed for outdoor use, while the 7F.20.9.024.1020 is the indoor version.
Both models are 24 V DC Size 1 outdoor filter fans. The key difference is airflow direction: the 7F.30.9.024.1020 is the standard draw-in version, while the 7F.31.9.024.1020 is the reverse flow exhaust version.
The Finder 7F.30.9.024.1020 combines compact Size 1 construction, 24 V DC operation, 24 m³/h nominal airflow, low 3.6 W power consumption, IP54 ingress protection, IK08 impact resistance and outdoor-oriented UL Type 3R construction. Its easily replaceable filter mat, low acoustic noise and space-saving mounting design make it a practical choice for electrical engineers, industrial panel builders, automation specialists and maintenance professionals working with outdoor electrical enclosures.
Manufacturer technical reference: Finder 7F Series Filter Fans – Technical Datasheet. Installation dimensions, environmental protection and operating requirements should be checked against the current manufacturer documentation before installation.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.