Finder 7F.30.8.230.2055 is a Size 2 outdoor intake filter fan for electrical enclosures, featuring 230 V AC operation, 55 m³/h free-air volume at 50 Hz, IP54 ingress protection, IK08 impact resistance, NEMA Type 3R classification, a 155 x 155 mm front housing, 125 x 125 mm nominal panel cut-out and replaceable filter mat.
£45.23
The Finder 7F.30.8.230.2055 is a 230 V AC outdoor filter fan designed to provide forced ventilation for electrical enclosures, industrial control cabinets and switchboards. Part of the Finder 7F Series, this Size 2 fan helps manage heat generated by electrical and electronic equipment while supporting protection against dust and environmental exposure.
Featuring a nominal 55 m³/h free-air volume at 50 Hz, the Finder 7F.30.8.230.2055 is designed for standard-flow intake ventilation. It draws external air through a replaceable filter mat and introduces it into the electrical enclosure, helping displace warmer internal air through a suitable exhaust opening.
Its IP54 ingress protection, IK08 impact resistance and NEMA Type 3R classification make it particularly suitable for appropriately designed outdoor electrical cabinet installations. The fan also features a compact 155 × 155 mm front housing, a 125 × 125 mm nominal panel cut-out and a convenient push-in electrical connection.
With its robust construction, straightforward installation and replaceable filter element, this Finder outdoor filter fan is a practical choice for electrical engineers, industrial automation specialists, panel builders and maintenance professionals.
The Finder 7F.30.8.230.2055 provides forced intake ventilation for electrical enclosures.
When the fan is energised, its electric motor draws air from outside the cabinet through the filter assembly and introduces it into the enclosure.
The incoming air circulates through the cabinet, helping remove heat generated by components such as power supplies, contactors, relays, controllers, transformers and electronic equipment.
As fresh air enters, warmer internal air is displaced through a suitable exhaust opening, establishing a controlled airflow path.
The fan provides a nominal 55 m³/h free-air volume at 50 Hz. This represents airflow under free-flow conditions rather than a guaranteed value for every installed cabinet.
Actual ventilation performance depends on filter condition, cabinet layout, exhaust opening resistance and other factors affecting the complete airflow path.
The Finder 7F.30 range is specifically intended for outdoor enclosure ventilation.
Compared with standard indoor filter fan arrangements, the outdoor range incorporates construction and protection features suitable for more demanding environmental conditions.
The IP54 rating indicates protection against harmful dust ingress and splashing water under the relevant test conditions.
The IK08 impact rating provides additional resistance to mechanical impacts, while the NEMA Type 3R classification supports suitable outdoor cabinet applications when the fan is installed correctly.
These ratings do not mean that the fan is suitable for immersion, unrestricted high-pressure washing or every possible outdoor exposure condition.
The completed enclosure must be assessed as a complete assembly, including seals, ventilation openings, cable entries and other fitted accessories.
The Finder 7F.30.8.230.2055 is a standard-flow outdoor filter fan designed to introduce air into an enclosure.
The corresponding Finder 7F.31 range provides reverse-flow exhaust operation for outdoor applications.
With standard intake ventilation, the fan draws external air into the cabinet and the warmer internal air exits through a separate exhaust filter.
This arrangement can help create positive pressure within the enclosure, depending on the relative airflow and resistance of the ventilation openings.
A reverse-flow fan actively extracts air from the cabinet instead.
The correct configuration depends on enclosure geometry, dust exposure, heat dissipation and the required direction of airflow.
The Finder 7F.30.8.230.2055 includes a replaceable filter mat that helps prevent airborne dust and debris from entering the cabinet with the ventilation air.
As the fan operates, dust may gradually accumulate within the filter material.
If the filter becomes heavily contaminated, airflow resistance increases and the cooling performance of the system may be reduced.
The filter should therefore be inspected periodically and replaced when necessary.
The Finder 7F Series is designed to simplify routine maintenance, allowing the filter material to be accessed without replacing the complete fan assembly.
Maintenance frequency should reflect the surrounding environment. Outdoor industrial cabinets exposed to airborne dust, pollen or debris may require more frequent inspection than installations in cleaner locations.
The Finder 7F.30.8.230.2055 operates from a nominal 230 V AC supply at 50/60 Hz.
This makes it suitable for appropriately protected installations using standard UK nominal mains voltage.
The fan can be connected through a suitable switching or control arrangement, including a compatible enclosure thermostat.
Temperature-controlled operation allows the fan to run when the cabinet temperature reaches a selected threshold.
Electrical installation must be carried out by a competent person using suitable circuit protection and wiring methods.
The supply voltage, protective arrangements and connection details should be checked against Finder's current installation documentation before energising the fan.
The Finder 7F.30.8.230.2055 features a 155 × 155 mm front housing and is designed for installation into a suitable electrical enclosure wall.
Its Size 2 format requires a nominal 125 × 125 mm mounting cut-out, with the manufacturer's specified +1.0 mm tolerance.
The fan uses a convenient push-in electrical terminal arrangement and is designed to simplify enclosure installation and maintenance.
For effective cooling, the filter fan should be positioned to promote airflow through the cabinet rather than allowing incoming air to pass directly to the outlet without circulating around heat-producing components.
Where practical, the intake and exhaust openings should be arranged to encourage circulation across the equipment requiring cooling.
The exact mounting method, panel thickness requirements and installation clearances should be confirmed against the supplied manufacturer's instructions.
Industrial electrical cabinets can contain numerous heat-generating components, including PLCs, power supplies, contactors, variable speed drives and electronic control modules.
Excessive internal temperatures can affect component performance and reduce long-term reliability.
The Finder 7F.30.8.230.2055 supports cabinet thermal management by introducing filtered external air to help remove accumulated heat.
Correct fan selection should consider the total heat dissipation inside the cabinet, the maximum expected ambient temperature and the permissible internal temperature.
Where the ambient temperature is equal to or higher than the desired internal cabinet temperature, ventilation alone may not provide sufficient cooling. A different thermal management approach may be required.
The fan should therefore be selected as part of a complete enclosure cooling design rather than solely by its free-air airflow rating.
Tick the specs you need, then view products that match.
| Cut-Out Size (mm) | 125 × 125 mm | |
|---|---|---|
| Manufacturer | Finder | |
| Series | 7F Series | |
| Type | 7F.30 | |
| Manufacturer part number | 7F.30.8.230.2055 | |
| Product type | Outdoor filter fan | |
| Application | Electrical enclosure ventilation | |
| Ventilation direction | Standard-flow intake | |
| Fan size | Size 2 | |
| Nominal operating voltage | 230 V AC | |
| Supply type | AC | |
| Frequency | 50/60 Hz | |
| Free-air volume at 50 Hz | 55 m³/h | |
| Free-air volume at 60 Hz | 63 m³/h | |
| Free-air volume at 50 Hz in imperial units | Approximately 32.4 CFM | |
| Published filtered airflow | Approximately 45.5 m³/h, depending on test configuration | |
| Nominal input power | Approximately 29–30 W | |
| Nominal operating current | Approximately 130 mA at the stated reference condition | |
| Front housing width | 155 mm | |
| Front housing height | 155 mm | |
| Nominal panel cut-out | 125 × 125 mm | |
| Panel cut-out tolerance | +1.0 mm | |
| Ingress protection | IP54 | |
| Impact protection | IK08 | |
| North American enclosure classification | NEMA Type 3R | |
| Ambient operating temperature | −30 to +55 °C | |
| Noise emission | Approximately 42 dB(A) | |
| Nominal service life | 50,000 hours at 40 °C | |
| Bearing type | Ball bearing | |
| Electrical connection | Push-in terminals | |
| Housing colour | Grey RAL 7000 | |
| Filter element | Replaceable | |
| Mounting | Enclosure wall or panel | |
| Corresponding outdoor exhaust filter | Finder 7F.03.0.000.2000 | |
| EAN | 8012823447797 | |
| Country of origin | Italy | |
| Compliance | CE, UKCA and RoHS |
The Finder 7F.30.8.230.2055 is an outdoor filter fan used to introduce filtered air into electrical enclosures, helping remove heat generated by industrial control and electrical equipment.
Yes. The Finder 7F.30 range is specifically designed for outdoor enclosure ventilation. This model features IP54 ingress protection, IK08 impact resistance and NEMA Type 3R classification when correctly installed.
The fan operates from a nominal 230 V AC supply at 50/60 Hz.
The fan has a nominal free-air volume of 55 m³/h at 50 Hz and 63 m³/h at 60 Hz. Actual installed airflow depends on the ventilation system resistance.
It is a standard-flow intake filter fan, designed to draw external air into an electrical enclosure. The Finder 7F.31 range provides reverse-flow exhaust versions for outdoor applications.
The fan has an IP54 ingress protection rating when correctly installed, helping protect against harmful dust ingress and splashing water.
It is a Size 2 filter fan with a front housing measuring 155 × 155 mm.
The Size 2 configuration requires a nominal 125 × 125 mm panel cut-out, with a specified +1.0 mm tolerance.
The fan has a published nominal input power of approximately 29–30 W, depending on the specified operating condition.
Yes. The filter mat is replaceable, allowing routine maintenance without replacing the complete fan assembly.
The Finder 7F.30.8.230.2055 is specified for an ambient operating temperature range of −30 to +55 °C.
The published noise level is approximately 42 dB(A). Actual perceived noise depends on installation conditions and the surrounding environment.
Yes. The fan can be switched using a suitable enclosure thermostat or controller rated for its 230 V AC motor load.
The Finder 7F.20 range is designed for indoor electrical enclosure ventilation, while the Finder 7F.30 range is intended for outdoor applications requiring additional environmental protection.
The corresponding Size 2 outdoor exhaust filter is the Finder 7F.03.0.000.2000. The complete ventilation arrangement should be checked for airflow capacity and installation compatibility.
The Finder 7F.30.8.230.2055 combines 230 V AC operation, 55 m³/h nominal free-air volume at 50 Hz, IP54 ingress protection and IK08 impact resistance in a compact Size 2 outdoor filter fan. Its replaceable filter mat, push-in electrical terminals and straightforward panel installation make it a practical choice for industrial electrical cabinet cooling and outdoor enclosure thermal management.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.