Finder 7F.30.8.120.4250 - 7F Series Filter Fans - For outdoor use

Finder 7F.30.8.120.4250 – 7F Series Filter Fans – For outdoor use

Finder 7F.30.8.120.4250 is a Size 4 outdoor draw-in filter fan with 120 V AC operation, 250 m³/h free-air flow at 50 Hz, 42 W rated power, IP54 protection and IK08 impact resistance for industrial electrical enclosure ventilation.

SKU: 7F.30.8.120.4250Alt SKU: 7F3081204250MPN: 7F.30.8.120.4250
Price
List Price £154.76 ex VAT
Your Price (ex VAT) Save 30%
£108.33 30% OFF
You save £46.43 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £108.33
Trade pricing is personalised to your account

Manufacturer Lead Time

£108.33

Why Choose the Finder 7F.30.8.120.4250 Outdoor Filter Fan?

The Finder 7F.30.8.120.4250 is a high-performance 120 V AC outdoor filter fan from the Finder 7F Series, designed to provide effective forced-air ventilation for outdoor electrical cabinets, industrial control panels and automation enclosures. This Size 4 standard-flow fan delivers a nominal free-air flow of 250 m³/h at 50 Hz, helping dissipate heat generated by electrical and electronic equipment.

Specifically developed for outdoor electrical enclosure applications, the Finder 7F.30.8.120.4250 combines IP54 ingress protection, IK08 impact resistance and a weather-resistant construction. Its standard draw-in airflow configuration introduces filtered ambient air into the cabinet, supporting controlled ventilation when paired with a suitable exhaust filter.

Featuring 120 V AC operation, 42 W rated power at 50 Hz, a 255 × 255 mm external face and a compact 90.2 mm installation depth, this outdoor filter fan provides an efficient solution for industrial enclosure cooling. Its replaceable filter mat and practical mounting arrangement help simplify installation and routine maintenance.

Key Advantages

  • 250 m³/h free-air flow at 50 Hz for effective electrical enclosure ventilation.
  • 295 m³/h free-air flow at 60 Hz for compatible supply frequencies.
  • 120 V AC operation for industrial electrical installations.
  • Outdoor-rated construction suitable for appropriately designed external control cabinets.
  • Standard draw-in airflow introduces filtered ambient air into the enclosure.
  • IP54 protection helps resist dust and water ingress when correctly installed.
  • IK08 impact resistance supports mechanical durability.
  • NEMA Type 3R classification for suitable outdoor enclosure applications.
  • 56 dB(A) noise level for controlled acoustic performance.
  • 42 W rated power at 50 Hz supports efficient forced-air cooling.
  • Replaceable filter mat simplifies maintenance.
  • 90.2 mm installation depth helps preserve usable enclosure space.
  • Suitable for industrial automation, machinery control and electrical distribution applications.

Key Features

  • Finder 7F Series outdoor filter fan.
  • 7F.30 standard-flow draw-in configuration.
  • Size 4 fan and filter assembly.
  • 120 V AC nominal operating voltage.
  • 50/60 Hz supply frequency.
  • 250/295 m³/h free-air flow at 50/60 Hz.
  • 195/228 m³/h airflow at 50/60 Hz with a compatible exhaust filter installed.
  • 42/48 W rated power at 50/60 Hz.
  • 0.35/0.40 A current consumption at 50/60 Hz.
  • 56 dB(A) acoustic noise level.
  • IP54 ingress protection.
  • IK08 mechanical impact resistance.
  • NEMA Type 3R outdoor classification.
  • 255 × 255 mm external face dimensions.
  • 90.2 mm installation depth.
  • Push-in electrical terminal arrangement.
  • Replaceable filter mat for routine servicing.
  • Designed for straightforward installation in compatible electrical enclosures.

Reliable Outdoor Enclosure Cooling for Industrial Automation

Outdoor electrical cabinets can experience elevated internal temperatures due to solar exposure, changing ambient conditions and heat generated by installed electrical equipment. The Finder 7F.30.8.120.4250 provides forced-air ventilation to help manage these temperatures in enclosures containing PLCs, power supplies, contactors, motor control equipment and electronic monitoring systems.

Its standard draw-in configuration introduces filtered ambient air into the electrical cabinet. When combined with a correctly positioned exhaust filter, the incoming air can circulate around heat-generating components before leaving the enclosure. This helps create an effective ventilation path while reducing the entry of airborne dust.

The fan delivers 250 m³/h free-air flow at 50 Hz and 295 m³/h at 60 Hz. With a compatible exhaust filter installed, the corresponding airflow figures are approximately 195 m³/h and 228 m³/h. Actual installed performance depends on enclosure resistance, filter condition, ventilation openings and ambient operating conditions.

The IP54, IK08 and NEMA Type 3R classifications support use in appropriately designed outdoor electrical installations. However, fan-assisted ventilation cannot reduce enclosure temperature below that of the incoming ambient air. Engineers should therefore assess the enclosure heat load, environmental exposure and required airflow before selecting the ventilation system.

Regular inspection and replacement of the filter mat help prevent airflow restriction, particularly in dusty industrial environments. Maintaining the filter and ensuring that ventilation openings remain clear supports reliable cooling performance throughout the installation's service life.

Typical Applications

  • Outdoor electrical control cabinet ventilation.
  • Industrial automation and PLC enclosures.
  • Outdoor machinery control panels.
  • Electrical distribution and switchgear cabinets.
  • Motor control and industrial drive enclosures.
  • Water treatment and pumping station control systems.
  • Outdoor process monitoring installations.
  • Infrastructure and utility control cabinets.
  • Industrial power supply and relay enclosures.
  • Manufacturing and production equipment.
  • OEM electrical panel construction.
  • Outdoor electrical enclosure ventilation upgrades.

Technical Specifications

Tick the specs you need, then view products that match.

Cut-Out Size (mm) 223 × 223 mm
Manufacturer Finder
Series 7F Series
Manufacturer part number 7F.30.8.120.4250
Product type Outdoor filter fan
Airflow configuration Standard flow / draw-in
Fan size Size 4
Nominal operating voltage 120 V AC
Supply frequency 50/60 Hz
Operating voltage range 0.8 to 1.1 × nominal voltage
Free-air flow at 50 Hz 250 m³/h
Free-air flow at 60 Hz 295 m³/h
Airflow with exhaust filter at 50 Hz 195 m³/h
Airflow with exhaust filter at 60 Hz 228 m³/h
Rated power at 50 Hz 42 W
Rated power at 60 Hz 48 W
Current consumption at 50 Hz 0.35 A
Current consumption at 60 Hz 0.40 A
Noise level 56 dB(A)
Protection rating IP54
Impact resistance IK08
NEMA classification Type 3R
External face dimensions 255 × 255 mm
Installation depth 90.2 mm
Electrical connection Push-in terminals
Fan bearing type Ball bearing
Housing material Flame-retardant plastic according to UL94 V-0
Filter Replaceable filter mat
Ambient operating temperature −30 to +55 °C
Nominal service life at 40 °C 50,000 hours
Application Outdoor electrical enclosure ventilation

Frequently Asked Questions

What is the Finder 7F.30.8.120.4250 used for?

The Finder 7F.30.8.120.4250 is an outdoor-rated filter fan designed to introduce filtered ambient air into electrical cabinets and industrial control enclosures. It helps dissipate heat generated by installed electrical equipment and supports suitable operating temperatures.

What is the airflow capacity of the Finder 7F.30.8.120.4250?

The fan provides 250 m³/h free-air flow at 50 Hz and 295 m³/h at 60 Hz. With a compatible exhaust filter installed, airflow is approximately 195 m³/h at 50 Hz and 228 m³/h at 60 Hz.

What voltage and power consumption does this outdoor filter fan have?

The Finder 7F.30.8.120.4250 operates from a 120 V AC supply at 50/60 Hz. Its rated power consumption is 42 W at 50 Hz and 48 W at 60 Hz.

Is the Finder 7F.30.8.120.4250 suitable for outdoor electrical enclosures?

Yes. The Finder 7F.30 range is designed for outdoor electrical enclosure ventilation. This model provides IP54 protection, IK08 impact resistance and a NEMA Type 3R classification when installed according to the manufacturer's instructions.

What are the dimensions and maintenance requirements of this filter fan?

The unit has a 255 × 255 mm external face and an installation depth of approximately 90.2 mm. Its replaceable filter mat should be inspected and serviced regularly to maintain effective airflow and reliable cabinet ventilation.

Designed for Industrial Automation Engineers and Electrical Panel Builders

The Finder 7F.30.8.120.4250 combines 120 V AC operation, 250 m³/h free-air flow at 50 Hz, IP54 protection, IK08 impact resistance and outdoor-rated construction in a Size 4 filter fan, providing a practical ventilation solution for industrial electrical cabinets, automation enclosures and outdoor control systems.