Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 7F.30.8.120.3100 is a Size 3 outdoor draw-in filter fan with 120 V AC operation, 100 m³/h nominal free-air flow at 50 Hz, IP54 protection, IK08 impact resistance and NEMA Type 3R classification for electrical enclosure ventilation.
£61.15
The Finder 7F.30.8.120.3100 is a 120 V AC outdoor filter fan from the Finder 7F Series, designed to provide reliable forced-air ventilation for electrical cabinets and industrial control enclosures. This Size 3 draw-in fan delivers a nominal free-air flow of 100 m³/h at 50 Hz, helping manage heat generated by electrical and electronic equipment.
Unlike standard indoor ventilation fans, the Finder 7F.30 range is specifically designed for outdoor enclosure applications. Its IP54 protection rating, IK08 impact resistance and NEMA Type 3R classification make it suitable for appropriately designed installations exposed to outdoor environmental conditions.
Featuring a 120 V AC supply, low-noise operation at 42 dB(A) and an easily replaceable filter mat, the Finder 7F.30.8.120.3100 combines effective ventilation with practical installation and maintenance. Its compact design helps minimise intrusion into the enclosure while supporting dependable cabinet cooling.
Outdoor electrical enclosures can experience elevated internal temperatures caused by solar exposure, ambient conditions and heat generated by installed electrical equipment. The Finder 7F.30.8.120.3100 provides forced-air ventilation to help dissipate heat from control cabinets containing PLCs, power supplies, relays, contactors and other automation components.
Its standard draw-in configuration introduces filtered ambient air into the cabinet. When paired with an appropriately positioned exhaust filter, this creates an airflow path through the enclosure, helping carry heat away from electrical components while reducing the entry of airborne dust.
The fan provides 100 m³/h free-air flow at 50 Hz and 115 m³/h at 60 Hz. With a compatible exhaust filter installed, the corresponding airflow figures are 75 m³/h and 85.5 m³/h. Actual installed airflow depends on filter condition, enclosure resistance and the ventilation arrangement.
The IP54, IK08 and NEMA Type 3R ratings support its use in appropriately designed outdoor installations. However, fan-assisted ventilation cannot cool an enclosure below the incoming ambient air temperature. Cabinet heat load, weather exposure, mounting position and the manufacturer's installation requirements should therefore be considered when designing the cooling system.
Tick the specs you need, then view products that match.
| Cut-Out Size (mm) | 177 × 177 mm | |
|---|---|---|
| Manufacturer | Finder | |
| Series | 7F Series | |
| Manufacturer part number | 7F.30.8.120.3100 | |
| Product type | Outdoor filter fan | |
| Airflow configuration | Standard flow / draw-in | |
| Fan size | Size 3 | |
| Nominal operating voltage | 120 V AC | |
| Supply frequency | 50/60 Hz | |
| Free-air flow at 50 Hz | 100 m³/h | |
| Free-air flow at 60 Hz | 115 m³/h | |
| Airflow with exhaust filter at 50 Hz | 75 m³/h | |
| Airflow with exhaust filter at 60 Hz | 85.5 m³/h | |
| Noise level | 42 dB(A) | |
| Protection rating | IP54 | |
| Impact resistance | IK08 | |
| NEMA classification | Type 3R | |
| External face dimensions | 209 × 209 mm | |
| Mounting cut-out | 177 × 177 mm nominal | |
| Installation depth | 71.2 mm | |
| Electrical connection | Push-in terminals | |
| Conductor cross-section | 0.7–2.5 mm² | |
| Filter material | Synthetic fibre | |
| Filter temperature resistance | Up to +100 °C | |
| Ambient operating temperature | −30 to +55 °C | |
| Nominal service life at 40 °C | 50,000 hours | |
| Application | Outdoor electrical enclosure ventilation |
The Finder 7F.30.8.120.3100 is an outdoor-rated draw-in filter fan used to ventilate electrical cabinets and industrial control enclosures. It introduces filtered ambient air into the cabinet to help remove heat generated by installed electrical equipment.
The fan provides 100 m³/h free-air flow at 50 Hz and 115 m³/h at 60 Hz. With a compatible exhaust filter installed, airflow is approximately 75 m³/h at 50 Hz and 85.5 m³/h at 60 Hz.
Yes. The Finder 7F.30 range is designed for outdoor electrical enclosure applications. This model has an IP54 protection rating, IK08 impact resistance and a NEMA Type 3R classification when installed according to the manufacturer's instructions.
The Finder 7F.30.8.120.3100 operates from a 120 V AC supply at 50/60 Hz. It should be connected to a compatible electrical supply using the manufacturer's recommended wiring and protection arrangements.
The fan has an external face measuring 209 × 209 mm, a nominal mounting cut-out of 177 × 177 mm and an installation depth of approximately 71.2 mm. Its replaceable filter mat should be inspected and serviced regularly to maintain effective airflow.
The Finder 7F.30.8.120.3100 combines 120 V AC operation, 100 m³/h nominal airflow at 50 Hz, IP54 protection, IK08 impact resistance and NEMA Type 3R outdoor suitability in a compact Size 3 filter fan, providing a practical ventilation solution for industrial electrical cabinets and automation enclosures.
We use cookies